![Canon GP405 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/canon/gp405/gp405_service-handbook_4161791038.webp)
CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-28
Notation
name
Meter probe
Service mode
Check (Normal if
described.)
Display reading
Meter reading (approx.)
PS14
Front cover open/
closed sensor (PS14S)
J102-A11
P003-bit4
While in standby, open
the front cover.
PS18
Cassette 1 pick-up
sensor (PS18S)
J108-A17
P004-bit0
While in standby, slide
out the cassette, and
insert paper between
the pick-up rollers.
PS19
Cassette 1 pick-up
sensor (PS19S)
J108-A18
P004-bit1
While in standby, slide
out the cassette, and
insert paper between
pick-up rollers.
When
paper is
inserted,
1
5 V
When the
front
cover is
open,
1
5 V
When the
front
cover is
closed,
0
0 V
When
paper is
not
inserted,
0
0 V
When
paper is
inserted,
1
5 V
When
paper is
not
inserted,
0
0 V
Notation
name
Meter probe
Service mode
Check (Normal if
described.)
Display reading
Meter reading (approx.)
PS40
Fixing assembly outlet
sensor (PS40S)
J114-A2
P004-bit9
While in standby, push
the lever on the fixing
assembly outlet
assembly.
When the
lever is
pushed,
1
5 V
When the
lever is
not
pushed,
0
0 V
Содержание GP405
Страница 42: ...CHAPTER 3 ARRANGEMENT AND FUNCTIONS OF ELECTRICAL PARTS 3 4 B Motors M1 M2 M3 M4 M5 M9 M7 M8 M10 M6 Figure 3 2 ...
Страница 176: ......
Страница 182: ...APPENDIX A 6 ...
Страница 190: ...A 14 ...
Страница 198: ......
Страница 200: ...PRINTED IN JAPAN IMPRIME AU JAPON 0199S1 8 1 This publication is printed on 70 reprocessed paper ...