CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-10
2
Positioning the Developing
Assembly Magnetic Seal
Mount the magnetic seal by butting it
against the opening as shown.
Check to make sure that the magnetic seal
is in firm contact with the housing.
Figure 2-14
Figure 2-15
Opening (butted)
Magnetic seal
Magnetic seal
(rear)
(front)
3
Mounting the Developing
Assembly Blade
The blade is adjusted to a high accuracy
when it is mounted to the blade mount. Avoid
detaching it from its mount.
•
If you must replace the blade on its own,
be sure to adjust the position of the blade
so that the gap between the blade and the
developing cylinder is 0.21 ±0.03 mm
when measured with a gap gauge (CK-
0057-000).
Figure 2-16
The surface of the developing cylinder
can easily be damaged. Be sure to slide the gap
gauge along its both ends.
Blade
Developing cylinder
0.21± 0.03mm