background image

ENG-7

Image Stabilizer

¡

When you use a tripod, the Image

Stabilizer should be turned off to save
battery power.

¡

The stabilizer is equally effective for hand-

held photography and photography with a
monopod.

¡

The image stabilizer function also

operates when the lens is used with an
Extension Tube EF12 ll or EF25 ll.

¡

Pictures may look distorted after being

taken depending on the camera, but this
doesn't affect shooting.

¡

If you set the camera’s Custom Function to

change the assigned button to operate the
AF, the Image Stabilizer will operate when
you press the newly assigned AF button.

¡

The Image Stabilizer cannot compensate

for a blurred shot caused by a subject that
moved.

¡

Set the STABILIZER switch to

when

you are taking pictures using the Bulb
setting (long exposures). If the
STABILIZER switch is set to

, the

image stabilizer function may introduce
errors.

¡

The Image Stabilizer might not be fully

effective in the following cases:
• You move the camera for a panned shot.
• You shoot while riding on a bumpy road.

¡

The Image Stabilizer consumes more

power than normal shooting, so fewer
shots can be taken if you use the function.

¡

The image stabilizer operates for about

two seconds even when your finger is off
the shutter button. Do not remove the lens
while the stabilizer is in operation. This will
cause a malfunction.

¡

With the EOS-1V/HS, 3, 30/33/Elan7/7E,

30V/33V/Elan7N/7NE, Elan ll/Elan ll
E/50/50 E, 300/Rebel2000, IX, and D30,
the Image Stabilizer will not work during
self-timer operation.

COP

Y

Содержание EF24-105MM F/4L IS USM

Страница 1: ...EF24 105mm f 4L IS USM Instruction ENG COPY ...

Страница 2: ... and super UD lens elements for excellent imaging performance 3 Ultrasonic motor USM for quick and quiet autofocusing 4 Manual focusing is available after the subject comes into focus in autofocus mode ONE SHOT AF 5 A truly round aperture hole results in a nicer background blur 6 Tight seal structure ensures excellent dust proof and drip proof performance Based on 1 focal length second Generally i...

Страница 3: ... device must accept any interference received including interference that may cause undesired operation Do not make any changes or modifications to the equipment unless otherwise specified in the instructions If such changes or modifications should be made you could be required to stop operation of the equipment This equipment has been tested and found to comply with the limits for a class B digit...

Страница 4: ... 4 Focus mode switch 5 Image stabilizer switch 6 Hood mount 9 Lens mount index 4 Filter mounting thread 10 Zoom ring 5 Focusing ring 5 Zoom position index 5 Nomenclature For detailed information reference page numbers are provided in parentheses COPY ...

Страница 5: ...tacts get soiled or have fingerprints on them clean them with a soft cloth If you remove the lens cover it with the dust cap To attach it properly align the lens mount index and the K index of the dust cap as shown in the diagram and turn clockwise To remove it reverse the order 1 Mounting and Detaching the Lens The lens mount has a rubber ring for enhanced water and dust resistance The rubber rin...

Страница 6: ... manual focus To shoot in autofocus AF mode set the focus mode switch to AF To use only manual focusing MF set the focus mode switch to MF and focus by turning the focusing ring The focusing ring always works regardless of the focus mode To zoom turn the lens zoom ring Be sure to finish zooming before focusing Changing the zoom ring after focusing can affect the focus COPY ...

Страница 7: ...s prohibited such as art museums and theater stages In situations where your footing is uncertain In situations where fast shutter settings cannot be used 1Set the STABILIZER switch to If you are not going to use the image stabilizer function set the switch to 2When you press the shutter button halfway the Image Stabilizer will start operating Make sure the image in the viewfinder is stable then p...

Страница 8: ...aused by a subject that moved Set the STABILIZER switch to when you are taking pictures using the Bulb setting long exposures If the STABILIZER switch is set to the image stabilizer function may introduce errors The Image Stabilizer might not be fully effective in the following cases You move the camera for a panned shot You shoot while riding on a bumpy road The Image Stabilizer consumes more pow...

Страница 9: ... setting when using monochrome infrared film Focus on the subject manually then adjust the distance setting by moving the focusing ring to the corresponding infrared index mark 6 Infrared Index Some EOS cameras cannot use infrared film See the instructions for your EOS camera The infrared index position is based on a wavelength of 800 nm The compensation amount differs depending on the focal lengt...

Страница 10: ... of the lens then turn the hood as shown by the arrow until the lens red dot is aligned with the hood s stop position mark The hood can be reverse mounted on the lens for storage Part of the picture may be blocked if the hood is not attached properly When attaching or detaching the hood grasp the base of the hood to turn it To prevent deformation do not grasp the rim of the hood to turn it 7 Hood ...

Страница 11: ...the polarizing filter first remove the lens hood 9 Extension Tubes Sold separately You can attach Extension Tube EF12 II or EF25 II for magnified shots The shooting distance and magnification are shown below Camera to Subject Magnification Distance mm Near Far Near Far EF12 II 24mm 177 187 0 60 0 50 105mm 326 1022 0 40 0 12 EF25 II 24mm Incompatible 105mm 280 574 0 61 0 27 Manual focusing is recom...

Страница 12: ...ely Attaching a 500D 77mm Close up Lens enables close up photography Magnification will be 0 34 0 05 Close up Lens 250D cannot be attached because there is no size that fits the lens Manual focusing is recommended for accurate focusing COPY ...

Страница 13: ...0 inch Max Diameter and Length 83 5 107 mm 3 3 4 2 inch Weight 670 g 23 6 oz Hood EW 83H Lens Cap E 77U Case LP1219 The lens length is measured from the mount surface to the front end of the lens Add 21 5 mm when including the lens cap and dust cap The size and weight listed are for the lens only except as indicated The EF1 4X II EF2X II extenders cannot be used with this lens Aperture settings ar...

Страница 14: ... CANON INC 2005 2009 7 CT1 7561 008 COPY ...

Отзывы: