Canon CR-2 AF Скачать руководство пользователя страница 6

6

2 Safety

Ensure that the entire system conforms to IEC 60601-1-1.
Use the equipment conforming to IEC 60601-1 in the patient 

environment.

Use the computer, monitor, and other equipment that conform to the system 
standard IEC 60601-1 or IEC 60950-1 for this product. Be sure that the entire 
system conforms to IEC 60601-1-1. Be sure to also use an isolation transformer 
conforming to IEC 60601-1 when a computer or monitor conforming to IEC 60950-1 
is used. 
Otherwise, electric shock may occur. For details, please contact your sales 
representative or local Canon dealer.

Make sure that the patient’s name, ID, birth date, and sex 

match those that are entered for the patient. 

If the entered information is incorrect, patients may be mixed up and misdiagnosed, 
which may result in physical injury to the patient.

Keep the forehead rest and chin rest clean.

To prevent the risk of infection, wipe the forehead rest with disinfectant ethanol for 
each patient. To ensure cleanliness, replace the chin rest paper for each patient. 
If the chin rest paper is not being used, be sure to disinfect the chin rest for each 
patient.
If the chin rest paper is not being used, be sure to disinfect the chin rest for each 
patient.
For details on how to disinfect, consult a specialist. The forehead rest may be 
corroded if a disinfectant other than those above is used.

Slowly move the main unit toward the patient’s eye when 

taking an image.

When adjusting the position of the main unit in the front-back direction, slowly bring 
the main unit closer to the patient while looking at the patient’s eye from the side.
The patient’s eye may be injured if the objective lens makes contact with it.

Check the image before using this product.

Before using this product, be sure to take a test image to ensure that there is no 
foreign matter present that can affect image readings or diagnosis.

Be sure to turn off the power when not in use.

For safety reasons, be sure to turn off the power of all the devices when this product 
is not being used.
Also, unplug the power plug from the AC outlet and put on the cover when this 
product is not going to be used for a long time.
Otherwise, dust or any foreign matter may accumulate and result in fire.

Do not touch the main unit while it is moving.

The main unit moves to the center position when this product main unit is turned on 
or an examination is finished with the control software. Do not touch the main unit  
while it is moving.

Before packing this product, return the main unit and chin 

rest to their lowest positions.

Lower the main unit and chin rest to the bottom. To automatically lower them, turn 
on the power while holding down the SET button.

EU_BT8-1756-EN01_CR-2_AF.indb   6

4/1/2020   1:28:11 PM

Содержание CR-2 AF

Страница 1: ...Digital Retinal Camera Instructions for Use CR 2 AF CR 2 Plus AF For Euporean Union EU_BT8 1756 EN01_CR 2_AF indb 1 4 1 2020 1 28 11 PM ...

Страница 2: ...ely Connection of a system that uses this product to a network could result risks to patients operators or third parties A dedicated individual who is assigned responsibility for maintenance should assess these risks in advance The responsible person should also assess the risks when changes to the network including changes in the network configuration addition or disconnection of items to the net...

Страница 3: ...to observe and record images of retinal fundus through the pupil without making contact with subject s eye for the purpose of diagnosis by way of producing fundus image information Composition Digital Retinal Camera Digital camera Control Software Optional products External eye fixation lamp unit EL 1 Chin rest paper 500 sheets 1Introduction EU_BT8 1756 EN01_CR 2_AF indb 3 4 1 2020 1 28 11 PM ...

Страница 4: ...has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user and or patient is established Electronic Instructions for Use Instructions for use are available on the website for viewing and download by customers https global canon en ifu medcom index html For details please contact your sales representative or local ...

Страница 5: ...C 60601 1 for networks between the computer and HUB Otherwise there is a risk of electric shock if the network is faulty Do not install in locations exposed to water steam moisture or dust Doing so may cause problems or malfunctions Do not install in locations exposed to salt sulfur or corrosive gas Doing so may result in corrosion of the instrument problems or malfunctions Do not install in locat...

Страница 6: ...st The forehead rest may be corroded if a disinfectant other than those above is used Slowly move the main unit toward the patient s eye when taking an image When adjusting the position of the main unit in the front back direction slowly bring the main unit closer to the patient while looking at the patient s eye from the side The patient s eye may be injured if the objective lens makes contact wi...

Страница 7: ...ot function properly Do not turn off the computer while the control software is running Be sure to exit the control software before shutting down the computer Doing so the measured data is not saved correctly or might corrupt the data On the Patient Info Edit screen use care when editing the patient information Regardless of all the essential data input disabled data and input format settings whic...

Страница 8: ...ge After use After using this product turn off the power cover the objective lens with the objective lens cap to protect it from dust and place the dust cover over this product You cannot take good images if the objective lens is dusty If the digital camera is detached and left unattached dirt and dust may enter the retinal camera and the digital camera Be sure to always attach the caps to their r...

Страница 9: ...r this product Installation Request your sales representative or local Canon dealer to install this product A strong shock to this product may put it out of alignment Please handle the unit carefully Transportation Lower the main unit and chin rest to the bottom To automatically lower them turn on the power while holding down the SET button When lifting the main unit do not hold the head rest or d...

Страница 10: ...associated with EEE At the same time your cooperation in the correct disposal of this product will contribute to the effective usage of natural resources For more information about where you can drop off your waste equipment for recycling please contact your local city office waste authority approved WEEE scheme or your household waste disposal service For more information regarding return and rec...

Страница 11: ...d or backward to unify the top and bottom of the image of the pupil 3 Have the patient stare at the internal eye fixation lamp to fix the part for the photograph 4 Perform a preliminary check before taking photos Control the operation lever and take the image 5 Check the photographed image Finishing an Examination 1 End the examination on control software 2 Align the stage with the base and slide ...

Страница 12: ... the power Turn on this product and start the control software Check the following items after starting an examination Main unit 1 The POWER lamp lights 2 The observation light brightness changes as the observation light brightness adjustment button is pressed 3 A flash is emitted 4 The main unit moves up and down as the main unit vertical movement ring is turned 5 The chin rest moves up and down ...

Страница 13: ...s representative or local Canon dealer Be ready to provide a detailed description of the symptoms and message Symptom Cause and remedy 5 short beeps sound and the operation panel lamps blink when the power is turned on A system error has occurred Contact your sales representative or local Canon dealer Err 06 Sensor cleaning is not possible Err 70 Photography is not possible due to an error 5Troubl...

Страница 14: ...ishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Warranty and Repair Service Service life The service life of this product is eight years if specified inspections and maintenance are performed Expendable parts replaced by service personnel The following parts are consumable or m...

Страница 15: ...EU_BT8 1756 EN01_CR 2_AF indb 15 4 1 2020 1 28 12 PM ...

Страница 16: ...facturer CANON INC 9 1 Imaikami cho Nakahara ku Kawasaki Kanagawa 211 8501 Japan Telephone 81 3 3758 2111 Revision Date 2020 04 BT8 1756 EN01 0420P0 001 CANON INC 2020 EU_BT8 1756 EN01_CR 2_AF indb 16 4 1 2020 1 28 12 PM ...

Отзывы: