The presence of the staple cartridge and the presence of the staples in the staple cartridge are detected by the staple sensor
(PS127). Whether the staple in the staple cartridge is pushed out to the leading edge of the cartridge is detected by the staple
edging sensor (PS126).
Cam
Staple Motor (M115)
Stapling Unit
• Number of sheets that can be stapled
Item
Specifications
Remarks
Number of
sheets that can
be stapled
Paper
Small size
Large size
- Paper thickness (small size): 11 mm or less
- Paper thickness (large size): 5.5 mm or less
Paper size regulations
Small size: feed length 220 mm or less
Large size: feed length more than 220 mm
52 to 90 g/
㎡
50 sheets
30 sheets
More than 90 to 105
g/m2
30 sheets
20 sheets
More than 105 to
256 g/m2
2 sheets
2 sheets
If a job is in the following condition, stapling is not performed, and the paper is delivered.
• When the number of sheets that can be stapled is exceeded
• When paper whose width is less than 210 mm or more than 297 mm is in use
• When paper whose length is less than 182 mm or more than 431.8 mm is in use
<Related service mode>
• (Lv.1) SORTER > ADJUST > STP-F1: Adjusting the front 1-staple position
• (Lv.1) SORTER > ADJUST > STP-R1: Adjusting the rear 1-staple position
• (Lv.1) SORTER > ADJUST > STP-2P: Adjusting the front/rear 2-staple position
• (Lv.1) SORTER > ADJUST > MSTP-2P: Adjusting the front/rear staple position at the manual staple mode
• (Lv.1) SORTER > OPTION > MSTP-TMG: Setting the staple timing at the manual staple mode
<Related error code>
• E531-8001: Staple Motor error
• E531-8002: Staple Motor error
• E532-8001: Stapler Shift Motor error
• E532-8002: Stapler Shift Motor error
Staple-free Binding Operation
■ Outline
Staple-free binding includes an operation that binds the specified number of sheets (5 sheets max.) using the staple-free binding
unit. The binding position is one location on the rear side.
In staple-free binding mode, the paper stack center-aligned by the processing tray is shifted to the staple-free binding position
by the alignment plate. The staple-free binding unit is driven by the staple-free binding motor (M116) to bind the paper stack.
The rotation status of the staple-free binding motor (M116) is detected by the staple-free binding motor clock sensor (PS130).
The binding unit's home position is detected by the staple-free binding HP sensor (PS129).
2. Technical Explanation
55
Содержание Booklet Finisher-AA1
Страница 1: ...Revision 4 0 Staple Finisher AA1 Booklet Finisher AA1 Service Manual ...
Страница 12: ...Product Overview 1 Features 5 Specifications 6 Names of Parts 14 Optional Configuration 20 ...
Страница 83: ...Periodical Service 3 Periodic Servicing Tasks 76 ...
Страница 87: ...3 Remove the 2 Connectors 1 2x 1 4 Parts Replacement and Cleaning 79 ...
Страница 89: ...Main Units Parts 4 5 6 7 8 1 2 3 4 Parts Replacement and Cleaning 81 ...
Страница 128: ...4x 1 2 2 3 3 2x 4 Parts Replacement and Cleaning 120 ...
Страница 150: ...Adjustment 5 Overview 143 Basic Adjustment 148 Adjustments When Replacing Parts 173 Other 184 ...
Страница 178: ...A B Feed Direction Stapling Position Fixing Screw A B Stitcher Unit Fixing Screw Fixing Screw Mark 5 Adjustment 170 ...
Страница 184: ... Adjsting Phase Angle of the Paddle Unit 1 Put off the belt 1 1 2 Lower the swing roller till its end 5 Adjustment 176 ...
Страница 193: ...Troubleshooting 6 Making Initial Checks 186 Processing Tray Area 187 Saddle Stitcher Area 188 ...
Страница 204: ...4 5 6 7 8 9 7 Installation 196 ...
Страница 205: ...10 7 Installation 197 ...
Страница 210: ...11 NOTE Keep the parts as illustration above Installation of Buffer Pass Unit 1 7 Installation 202 ...
Страница 223: ...2 3 2x 7 Installation 215 ...
Страница 224: ...APPENDICES Service Tools 217 General Circuit Diagram 218 ...