Technology > Function > Power supply > Power connection with each option
Technology > Function > Power supply > Power connection with each option
Power supply
■
Power connection with each option
Indicating the power supply path between the Printer and Option.
Reader / ADF Unit
Paper Deck
Unit-B1
Booklet Finisher-C1
Cassette Feeding Unit-AD1
Built-in wiring
Connector inside the cover is used for the connection with the printer.
F-2-11
When power is turned ON, the connected equipment supplies 24VDC and 5VDC to the
Pedestal Controller PCB.
24VDC is used to drive the motor and solenoid. 5VDC is used to drive the sensor and IC.
In addition, 24VDC and 5VDC are supplied to the Paper Deck Unit B1 via the equipment.
Pedestal controller PCB
Connect in device
+3.3V
IC
+5U
5V
24V
24V
IC7
24V
Regulator
Sensor
FU4
Motor,
Solenoid
Paper deck
Unit B1
Controller
power supply
PCB
DC
Controller
PCB
Controller
power supply
PCB
F-2-12