5
9. The appliance should be inspected prior to use, with regular
inspections (annually) to be made by a licensed service per-
son. It is important that circulating air passageways of the ap-
pliance be kept clean, dirt and lint free, for a safe and efficient
operation of the heater.
10. On first lighting your heater a smell may occur due to it’s new
condition. This is quite normal and will disappear after a few
hours use at the maximum control position.
Important:
WHEN THIS HEATER IS OPERATING, THE MESH GUARD IS
HOT.
The mesh guard fitted to the heater conforms to AGA requirements.
For heaters fitted with the optional glass front it should be noted that
THE GLASS FRONT IS HOT.
For permanent protection of young children or the infirm a second-
ary guard should be placed around the heater. A secondary guard
is not provided with this heater and may be purchased by the
owner.
This appliance meets the following standards:
Standards Australia: AS 3100
AS 5601/AG 601
AS 4553/AG 103
Standards
20
To check the operation of the electronic (module) controller (Type 537 ABC) you will require a digital
multimeter with the functions to measure AC/DC voltage, continuity, resistance and micro-amps.
It is critical that the appliance is earthed and that the active and neutrals are not reversed.
Item No
Check
Action
1
No ignition when appliance
• Check 240 volts power to heater in incoming plug
is turned on.
connector.
2
Power present but appliance
• If there is power to the brown wire in the 8 way
not operating.
switch connector the module may be in lockout
mode. To reset the module turn off the power supply
for 10 seconds and then turn the power on again.
3
After resetting the module
• Check the internal 3.5 amp fuse in the module.
and appliance is still not
operating.
4
If the fuse is O.K. and still
• Check other connections are in place.
appliance not operating
• If the last checks are correct the ignition electrode
should spark at the same time as the gas control
solenoid valves open. At this point the spark
electrode will activate for up to 10 seconds maxi
mum until the flame has been established. Terminal
14 (white wire into the 8 way switch connector)
will be energised as soon as the flame has been
sensed.
5
Confirm spark is produced
• A blue spark can be seen when the heater ignition
when heater is turned on.
process starts. Ensure spark is present between
electrode and burner.
6
If no spark being produced
•
Check that spark lead is connected into module.
•
Check the continuity of the HT cable.
•
Check that there is no short circuit to earth and
spark gap is correct. (Refer figure 28). A positive
check is to use a jumper wire and connect one end
of the earth and hold the other end with insulated
pliers 4mm from the spark generator on the module.
If there is no spark to earth then change the module.
7
Spark is being produced
• Listen for cracking sound. The spark is misdirected.
but not at burner.
Check the spark ceramic insulator for signs of
cracks.
8
Sparks, ignites on low flame
• Check that the wall socket to the appliance has
then extinguishes after 10
correct polarity. Do not use an extension cord. Check
seconds. Continues to spark
polarity in the electrical supply lead to appliance.
during flame presence.
• Check that the sense electrode is in the flame.
• Check that appliance is earthed correctly. A check
between the earth pin on the plug and an unpainted
part of the appliance should see a resistance of
0.1 ohms.
Troubleshooting