background image

6

1. Plug the power cord into the wall socket and turn on the power

to the heater, see figure 1. Use of an extension cord is not

recommended

2. For control lay-out refer to figure 2

3. To turn heater on press switch to POWER ON position. There

is a 5 second delay before the burner ignites. At this setting the

burner is on LOW and the fan speed is on LOW. Refer

figure 3.

The burner will ignite on both HIGH and LOW settings.

4. To turn burner to HIGH setting, press switch for HIGH setting.

Refer figure 4.

User instructions

Operating instructions

1

2

4

3

19

Wiring diagram

Authorised service agents

For further information or spare parts contact the CANNON

distributor in your state.

Sampford & Staff Pty Ltd

421 Smith Street.

Fitzroy, Vic, 3065

Vic/Tas:

(03) 9418 5800

NSW:

(02) 9331 8888

SA/NT:

(08) 8212 7000

Qld:

(07) 3358 3000

WA:

(08) 9242 5333

ACT:

(02) 6280 4177

Elsewhere: 1800 334 887
email:

service @sampford.com.au

Содержание Fitzroy

Страница 1: ...s approved for use with Natural and Propane gases Please leave instructions with the owner FITZROY PROFILE MAKER S WARRANTY FREESTANDING MODELS FITZP FITZLP USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS ...

Страница 2: ...ons 10 15 Clearances Installation Gas connection Fuel bed log installation Gas control Gas pressure point Flue installation 16 17 Flue kit Service instructions 18 19 General Access to components To replace the gas control To replace the fan To replace the electronic controller To remove the burner and electrodes Wiring diagram Authorised service agents Trouble shooting 20 21 Connections Notes 22 2...

Страница 3: ...e its warranty voided If installation is not carried out in accordance with manufacturer s instructions this warranty may be void The customer must keep their Tax Invoice as proof of purchase of this product and compliance certificate as proof of required instal lation Model number ______________________________________ Serial number _______________________________________ Date of manufacture ____...

Страница 4: ...ins clothing furniture and other flammable mate rials at least 900mm from front rear and sides of the heater At the owner s discretion curtain clearance can be less than 900mm as long as they are restrained from the front top and sides of the heater The manufacturer takes no responsibility if curtain clearance is less than 900mm and not restrained 4 Children and adults should be alerted to the haz...

Страница 5: ...ear after a few hours use at the maximum control position Important WHEN THIS HEATER IS OPERATING THE MESH GUARD IS HOT The mesh guard fitted to the heater conforms to AGA requirements For heaters fitted with the optional glass front it should be noted that THE GLASS FRONT IS HOT For permanent protection of young children or the infirm a second ary guard should be placed around the heater A second...

Страница 6: ...gure 2 3 To turn heater on press switch to POWER ON position There is a 5 second delay before the burner ignites At this setting the burner is on LOW and the fan speed is on LOW Refer figure 3 The burner will ignite on both HIGH and LOW settings 4 To turn burner to HIGH setting press switch for HIGH setting Refer figure 4 User instructions Operating instructions 1 2 4 3 ...

Страница 7: ...itch for HIGH setting Refer figure 6 7 To turn the burner to LOW setting press switch for LOW set ting Refer figure 7 On low burner setting it is more efficient to operate the fan speed on LOW 8 If the burner fails to ignite wait 20 seconds and repeat the ignition procedure See below To turn burner OFF To turn burner ON 5 6 7 ...

Страница 8: ...s attention contact your supplier or licensed service person listed in this manual Important The appliance should be inspected before use and at least annu ally by an authorised service person More frequent cleaning may be required due to excessive lint build up from carpeting bedding materials pet hair etc It is imperative that control compartments burners and circulating air passage ways of the ...

Страница 9: ...20 kPa NG For Propane gas regulated to supply 2 65 kPa Gas regulator Integral with controller Fan Three speed Controller Electronic Power requirement 240 VAC 10 A Optional Accessories Safety guard Gold or silver trim Glass front Cathedral ceiling flue box Flue kit 3 x 900mm lengths of 125mm ø painted flue 1 x 900mm length of 125mm ø plain flue 1 x ceiling ring 1 x 900mm painted bottom flue spigot ...

Страница 10: ...refer to warning 3 on page 4 For minimum clearances refer fig 9 and 10 4 Remove the carton from the heater and lift from pallet Check that the heater is suitable for the gas available Please dispose of packaging appropriately keep away from children 5 Prepare electrical and gas connections a 10 Amp wall socket needs to be located within 1 5m of the heater 6 Fit rear spacers as per figure 10 7 Plac...

Страница 11: ...e the heater front by pulling it towards you gently to partly disengage it from the body of the heater then gently lift it up vertically to completely disengage it Refer figure 13 11 Remove the inner glass Slacken off screws in top clamp and remove side clamps Refer figure 14 11 12 13 14 ...

Страница 12: ... MUST BE HARD UP AGAINST REAR OF BURNER 14 Carefully unpack the log set Logs are numbered as follows No 1 Left front log No 2 left back log No 3 Right front log No 4 Right back log Position the four individually numbered logs in the following order on the fuel bed as shown in figures 17 20 The male locating pins in fuel bed must engage with corresponding holes in the individual logs a Place log No...

Страница 13: ... in No 3 log Refer figure 20 15 Refit the inner glass but do not overtighten the screws 16 Refit the front glass surround Ensure that the glass surround is replaced the correct side up 17 Gas control layout is as indicated in figure 21 Pressures for Burner full on and Burner low flame are factory set however if pressures need to be checked or adjusted follow the procedures described below and on t...

Страница 14: ...ull On position as indicated in figure 24 a and using a ring spanner as per figure 24 b adjust the pressure to 1kPa for Natural gas or 2 65 kPa for LPG Turn clockwise to increase pressure and anticlockwise to decrease pressure 20 Switch the stop button back to Low Flame position as indi cated in figure 25 a retain spanner in position and using a screwdriver as per figure 25 b adjust the central sc...

Страница 15: ...tioned towards lower right hand side to clear the control 28 Refit the lower front cover making sure not to damage the power cord 29 Follow User Instructions to turn on heater Important To achieve the correct visual flame effect On Propane the gas pressure must be set at 2 65 kPa with burner operating on maximum setting On Natural Gas the gas pressure must be set at 1 0 kPa 25 ...

Страница 16: ...ate against the wall 1 Ensure clearances to combustible have been observed For clear ances refer page 10 2 The centre line of the flue is 120mm to rear of appliance includ ing rear spacers 3 Carry out installation as per figure 26 ceiling plate installation and figure 27 flue installation Cut a hole 180mm ø in the ceiling in line with the flue position Secure ceiling plate against the ceiling by b...

Страница 17: ...17 27 ...

Страница 18: ...replace the fan 1 Disconnect the fan from the fan plug 2 Undo the two M5 wing nuts fixing the fan to the burner chamber underside 3 Replace in reverse order To replace the electronic controller 1 Remove two screws from controller front 2 Disconnect the plug 3 Replace in the reverse order To remove the burner and electrodes 1 Follow steps 9 to 11 of the installation instructions 2 Remove the logs a...

Страница 19: ...spare parts contact the CANNON distributor in your state Sampford Staff Pty Ltd 421 Smith Street Fitzroy Vic 3065 Vic Tas 03 9418 5800 NSW 02 9331 8888 SA NT 08 8212 7000 Qld 07 3358 3000 WA 08 9242 5333 ACT 02 6280 4177 Elsewhere 1800 334 887 email service sampford com au ...

Страница 20: ...te wire into the 8 way switch connector will be energised as soon as the flame has been sensed 5 Confirm spark is produced A blue spark can be seen when the heater ignition when heater is turned on process starts Ensure spark is present between electrode and burner 6 If no spark being produced Check that spark lead is connected into module Check the continuity of the HT cable Check that there is n...

Страница 21: ...han 1 5 micro amps at all times Take precaution because the ionisation probe can have a high negative voltage and can cause shock 11 Fuse blowing If the fuse continues to blow check the solenoid coils for signs of them being shorted Check the fan is and wiring for short circuit Terminals 5 6 and 7 at the module 12 way connector are bridged Terminal 10 at the module 12 way connector is the active s...

Страница 22: ...22 Notes ...

Страница 23: ...23 Notes ...

Страница 24: ...F IN Part No F2774 Revision C Cannon FITZROY PROFILE ...

Отзывы: