All cleaning should be carried out when the heater is cold.  Nor-

mally the heater should only need wiping with a lint - free damp

cloth.  Any stubborn stains can be removed with a non-abrasive

spray on cleaner. If an abrasive cleaner is used the paint finish will

be damaged.

Internally the heater should only be cleaned by a licensed service

person listed in this manual.

If your heater requires attention contact your supplier or licensed

service person listed in this manual.

Important:

The appliance should be inspected before use and at least annu-

ally by an authorised service person. More frequent cleaning may

be required due to excessive lint build-up from carpeting, bedding

materials, pet hair, etc.

It is imperative that control compartments, burners and circulating

air passage ways of the appliance be kept clean.

Do not use this fire if the glass is cracked or with the glass safety

screen removed.

Cleaning.

User instructions continued

17

23. Gas control layout is as indicated in figure 33.

Pressures for ‘Burner full on’ and ‘Burner low flame’ are fac-

tory set, however if pressures need to be checked or adjusted

follow the procedures described below and on the next two

pages.

    

To check control outlet pressure at burner ‘Full on” and ‘Low Flame”

positions remove the plastic cap from the regulator adjustment lo-

cation as indicated in figures 34 (a) & (b).

24 The pressure point is closed with a captive screw. Turn screw 6

revolution anticlockwise to open the pressure point as indicated on

figure 35 (a) and place manometer tube over the test point as per

figure 35 (b).

       

33

Gas pressure point

34

35

Gas control

Содержание FITZPIB

Страница 1: ...TALLATION INSTRUCTIONS SERVICE INSTRUCTIONS Cannon This heater is approved for use with Natural and Propane gases Please leave instructions with the owner INBUILT MODELS FITZPIB FITZPIBLP FITZROY PROF...

Страница 2: ...binet depth spacer Installation into a masonry fire place Sealing Gas connection 15 16 Fuel bed log installation Gas control 17 18 Gas pressure point Gas pressure adjustment Service instructions 19 Ge...

Страница 3: ...accordance with manufacturer s instructions this warranty may be void The customer must keep their Tax Invoice as proof of purchase of this product and compliance certificate as proof of required inst...

Страница 4: ...ture and other flammable mate rials at least 900mm from front and sides of the heater At the owner s discretion curtain clearance can be less than 900mm as long as they are restrained from the front t...

Страница 5: ...ide CO poisoning and possible death 11 The appliance should be inspected prior to use with regular inspections annually to be made by a licensed service per son It is important that circulating air pa...

Страница 6: ...2 3 To turn heater on press switch to POWER ON position There is a 5 second delay before the burner ignites At this setting the burner is on LOW and the fan speed is on LOW Refer figure 3 The burner w...

Страница 7: ...itch for HIGH setting Refer figure 6 7 To turn the burner to LOW setting press switch for LOW set ting Refer figure 7 On low burner setting it is more efficient to operate the fan speed on LOW 8 If th...

Страница 8: ...f your heater requires attention contact your supplier or licensed service person listed in this manual Important The appliance should be inspected before use and at least annu ally by an authorised s...

Страница 9: ...with controller NG Min inlet pressure 1 13 kPa NG Propane gas Regulated to supply 2 7 kPa to appliance Fan Three speed Controller Electronic Minimum cavity Height 605mm dimensions dimensions Width 700...

Страница 10: ...clear ances to furniture and curtains refer to warning on page 4 For minimum clearances refer figures 9 and 10 Note Ensure that the combustion air opening under the heater is not obstructed A CLEARAN...

Страница 11: ...r figure 12 d Fix spacer to front frame with 7 s t screws provided Refer fig 13 e Replace the front frame spacer assembly by sliding the assembly down over the cabinet top flange and then push ing it...

Страница 12: ...qualified elec trician 7 Remove the lower front cover by unscrewing two M5 screws from the air intake slot Refer figure 16 If unit is fitted with supply flexible cord ensure that the cord cannot be t...

Страница 13: ...gaps between heater case and fireplace are to be sealed Seal with foam tape around top and sides of heater flange as required Refer figure 22 Seal with fibreglass between bottom of heater case and bas...

Страница 14: ...fed through the hole at the rear bottom RHS of the heater Refer figure 24 and gas connection figure 26 14 With heater in position flanges should be hard against ma sonry Secure case flanges to the ma...

Страница 15: ...tained by a spring clip fixed to the rear of the burner chamber Refer figure 28 FUEL BED MUST BE HARD UP AGAINST REAR OF BURNER 17 Carefully unpack the log set Logs are numbered as follows No 1 Left f...

Страница 16: ...ce log No 4 on single right back pin ensure left side of log rests on depression in No 3 log see figure 32 18 Refit the inner glass making sure not to over tighten the screws 19 Refit the front glass...

Страница 17: ...wo pages To check control outlet pressure at burner Full on and Low Flame positions remove the plastic cap from the regulator adjustment lo cation as indicated in figures 34 a b 24 The pressure point...

Страница 18: ...a for Natural Gas and 1 1 kPa for LPG Turn clock wise to increase pressure and anticlockwise to decrease pressure 27 Switch burners off and remove the manometer tube Tighten pressure test point by tur...

Страница 19: ...ing nuts fixing the fan to the burner chamber underside 3 Replace in reverse order 1 Remove two screws from controller front 2 Disconnect plug 3 Replace in reverse order 1 Follow steps 7 to 11 of the...

Страница 20: ...roduced Check that spark lead is connected into module Check the continuity of the HT cable Check that there is no short circuit to earth and spark gap is correct Refer figure 38 A positive check is t...

Страница 21: ...han 1 5 micro amps at all times Take precaution because the ionisation probe can have a high negative voltage and can cause shock 11 Fuse blowing If the fuse continues to blow check the solenoid coils...

Страница 22: ...ct the CANNON dis tributor in your state Sampford Staff Pty Ltd 421 Smith Street Fitzroy Vic 3065 Vic Tas 03 9418 5800 NSW 02 9331 8888 SA NT 08 8212 7000 Qld 07 3358 3000 WA 08 9242 5333 ACT 02 6280...