9
Do not use fire with broken or missing logs.
Gas type:
Natural or Propane gas, as indicated
on data label
Gas consumption:
26 MJ/hr input
Energy star rating:
3.77
Energy output:
20.7 MJ/hr
Heater type:
Heater approved to
AS 4553/AG103.
Operating pressure:
Natural gas: 1.0 kPa
Propane gas: 2.65 kPa
Gas regulator:
Integral with controller (NG)
Min. inlet pressure:
1.13 kPa (NG)
Propane gas: Regulated to supply 2.7
kPa to appliance
Fan:
Three speed
Controller:
Electronic
Minimum cavity
Height: 605mm dimensions*
dimensions
Width: 700mm
Depth: 393mm
Power requirement:
240 VAC 10 A
Optional Accessories:
• Glass front
• Gold or silver trim
• Mock fireplace installation kit*
• Cabinet depth spacer
• Heater surround
Overall dimensions:
Refer fig. 8
*
Note: when installing into a mock fireplace a mock
fireplace installation kit must be used.
Heater Specifications
8
16
b) Place log No.2 onto the 2 left back pins. Refer figure 30.
c) Place log No.3 on single right front pin, ensure fork
locates over log No. 2, see figure 31.
d) Place log No. 4 on single right back pin, ensure left side
of log rests on depression in No. 3 log, see figure 32.
18. Refit the inner glass, making sure not to over tighten the screws.
19. Refit the front glass surround.
20. Reconnect the switch loom to the electronics module.
21. Refit the front glass surround.
22. Connect plug to the wall socket and switch it on.
31
32
30
Содержание FITZPIB
Страница 23: ...23...
Страница 24: ...INS Part No F2752 Revision B Cannon FITZROY PROFILE...