STUD
STUD
C.L. OF
HEATER
345 mm TO 610 mm
FLUE OPENING
GAS INLET
325 mm
338 mm
160 mm
3
0
m
m
5
5
5
m
m
FLUE
OPENING
DETAIL
METHOD A
610 mm MIN
BETWEEN TOP OF
COWL AND NEAREST
PART OF ROOF
75 mm MAIN
STUD WALL
ADJUSTMENT
STRAP
HEADER
TWIN
SKIN FLUE
TOP PLATE
FLUE SUPPORT
FLUE ADAPTER
FLASHING
FLUE CLAMP
FLUE COWL
APPROVED
TO AG604
ROOF CLADDING
100 mm DIA
FLUE PIPE
MAINTAIN 25 mm
CLEARANCE BETWEEN
FLUE AND WOODWORK
WALL CLADDING
12 mm FROM
BOTTOM OF
WALL CLADDING
TO TOP OF HEATER
MEASURE DISTANCE FROM
FLOOR TO TOP OF HEATER
FLUE OUTLET PLUS 2 mm
COWL
FIT
3 SCREWS
SMALL DIA
END WITH
SWAGE
TOP PLATE
FLUE SUPPORT
FLUE
ADAPTER
SINGLE
SKIN FLUE
Page 2.
Page 7.
FIG 6.
FIG 1.
MOCK FIREPLACE ENCLOSURE RECOMMENDATIONS
THE ENCLOSURE CAN BE FABRICATED USING ANY MATERIALS
PROVIDING THAT SPACER BRACKETS ARE FITTED TO THE HEATER
PROVIDING ADEQUATE CLEARANCES TO COMBUSTIBLE MATERIALS.
(SEE FIG 5)
THE AREA OF THE CAVITY MUST NOT EXCEED OUR DIMENSIONS AS
SHOWN IN THE DIAGRAM. (SEE BELOW)
IF THE ENCLOSURE IS LARGER THAT OUR DIMENSIONS ALLOW, A
SEPARATE BOXED SECTION AROUND THE HEATER WILL NEED TO BE
CONSTRUCTED.
THE HEATER MUST SIT ON A SOLID, SEALED BASE AND THE
ENCLOSURE MUST BE SEALED FROM ANY DRAUGHT AND BE
INSULATED AS NECESSARY TO ELIMINATE LOW TEMPERATURES.
OUR BROCHURE ILLUSTRATES AN ENCLOSURE CONSTRUCTED TO
AN EXISTING ROOM WITH A SOLID FLOOR AND CEILING, ANY OTHER
ENCLOSURE MUST HAVE THE SAME CHARACTERISTICS OF BEING
SEALED FROM ANY DROUGHT AND SUITABLY INSULATED FROM
LOW TEMPERATURES. FAILURE TO ADHERE TO THIS REQUIREMENT
WILL RESULT IN UNRELIABLE OPERATION OR FAILURE TO OPERATE
CORRECTLY AND IS NOT COVERED BY OUR WARRANTY CONDITIONS
300mm MAX
2400mm MAX
550mm MAX
MAKE SURE THERE IS ADEQUATE VENTILATION IN ROOM.