background image

CAVITY REQUIREMENTS.  

OVERALL DIMENSIONS OF THE INSERT CABINET. 

(SEE FIG 2 AND 3. )

735mm

FIG 3.

FIG 6.

Page 3.

Page 6.

* HEIGHT                                               625 mm
* WIDTH                                                 735 mm
* DEPTH                                                430 mm

625 mm

430mm

THE HEATER FOR INSTALLATION INTO A MOCK
FIREPLACE IS SUPPLIED WITH THE FOLLOWING PARTS.

F1404     REAR BRACKETS
F1405     TOP & SIDE SPACER BRACKETS
F1406     INSULATION BLANKET 

(ALREADY FITTED TO THE HEATER)

F3084     INSTRUCTION BOOKLET
      

2 OFF
4 OFF
1 OFF
1 OFF

FIG 2.

CLEARANCES FOR INSTALLATION INTO A COMBUSTIBLE ENCLOSURE 
USING A MOCK FIREPLACE KIT. (Pt No F3084)

(SEE FIG 6.)

CEILING

MANTLE

300 MIN

1000 MIN
CLEARANCE

3

8

0

4

8

5

6

0

5

6

5

0

 M

IN

4

4

0

 M

IN

695

 50

50

795 MIN

PLAN VIEW

SIDE VIEW

160 mm

GAS SUPPLY

10 mm 

75 mm GAS SUPPLY

FLUE DIA 100 mm

FLUE TERMINAL

Содержание FFITZROY PROFILE PWR

Страница 1: ...WR TO SUIT MOCK FIREPLACE INSTALLATIONS INSTALLATION INSTRUCTIONS FOR FITMENT INTO A COMBUSTIBLE ENCLOSURE This heater is for use with Natural Gas Read these instructions in conjunction with heater in...

Страница 2: ...ge 1 a CLEARANCE FROM COMBUSTIBLE P ge a 2 OVERALL DIMENSIONS OF CABINET P ge a 3 5 Pa 4 ge FITMENT OF SPACER BRACKETS AND BLANKET CAVITY CLEARANCE REQUIREMENTS Page 6 7 INSTALLATION DETAIL ADVICE P g...

Страница 3: ...LING THIS POWER FLUE HEATER INTO A MOCK FIREPLACE A MOCK FIREPLACE INSTALLATION KIT MUST BE USED FOR INSTALLATION INTO A MOCK COMBUSTIBLE FIREPLACE CONSTRUCTED FROM TIMBER AND OR PLASTERBOARD THE FLUE...

Страница 4: ...IBLES BETWEEN HEATER CABINET AND OTHER COMBUSTIBLE SURFACES 50 mm CLEARANCE FROM BOTH TOP AND SIDE SURFACES 50 mm CLEARANCE FROM REAR 50 mm CLEARANCE BETWEEN SIDE OF THE HEATER FRONT AND COMBUSTIBLES...

Страница 5: ...m WIDTH 735 mm DEPTH 430 mm 625 mm 430mm THE HEATER FOR INSTALLATION INTO A MOCK FIREPLACE IS SUPPLIED WITH THE FOLLOWING PARTS F1404 REAR BRACKETS F1405 TOP SIDE SPACER BRACKETS F1406 INSULATION BLAN...

Страница 6: ...ETS 1 THE SPACER LOCATION ARE MARKED ON THE HEATER CABINET INSERT SEE FIG 4 2 REMOVE THE FIXING SCREWS NEXT TO THE SHADED SECTIONS MARKED ON THE HEATER CABINET INSERT SEE FIG 4 FIG 4 FOR MOCK INSTALLA...

Страница 7: ...ONS USING EXISTING SCREW POSITIONS 4 FIT REAR SPACER BRACKETS TO HEATER CABINET ON DIAGONAL CORNERS AS SHOWN SEE FIG 5 SEE FIG 5 FLUE ENTRY FIXING SCREWS No8 x 3 8 SELF TAPPING REAR BRACKET TOP SIDE B...

Страница 8: ...N INTO A COMBUSTIBLE ENCLOSURE USING A MOCK FIREPLACE KIT Pt No F3084 SEE FIG 6 CEILING MANTLE 300 MIN 1000 MIN CLEARANCE 380 485 605 650 MIN 440 MIN 695 50 50 795 MIN PLAN VIEW SIDE VIEW 160 mm GAS S...

Страница 9: ...INSTALLATION DETAIL Page 7 REFER TO THE INSTALLATION BOOKLET SUPPLIED WITH THE HEATER...

Страница 10: ...MAINTENANCE IF YOUR HEATER REQUIRES ATTENTION CONTACT SAMPFORD AND STAFF PTY LTD ON PH 1300 727 421 FAX 1300 727 425 Page 8...

Страница 11: ...NOTES 5 Page 9...

Страница 12: ...REF F3084 C REVISION C DATED FEB 2007...

Отзывы: