GENERAL

THIS HEATER SHALL ONLY BE INSTALLED BY AN AUTHORIZED 
PERSON. THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE 
WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS, AG 5601,  
MUNICIPAL BUILDINGS CODES, ELECTRICAL  WIRING REGULATIONS 
AND ANY OTHER STATUTORY REGULATIONS.

TO CONFORM WITH THE AUSTRALIAN STANDARDS APPROVAL 
REQUIREMENTS, THE SPACERS MUST BE PERMANENTLY FITTED 
TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLE 
MATERIALS.

THESE MOCK FIREPLACE INSTALLATION INSTRUCTIONS AND 
SAFETY WARNINGS SHALL BE READ IN CONJUNCTION WITH THE 
HEATER INSTALLATION BOOKLET AND THE SAFETY WARNING IN
THAT MANUAL. (SEE PAGES 3&4)

Page 1.

IMPORTANT NOTE: 
WHEN INSTALLING THIS POWER FLUE HEATER INTO A MOCK 
FIREPLACE , A MOCK FIREPLACE INSTALLATION KIT MUST BE USED.

FOR INSTALLATION INTO A (MOCK) COMBUSTIBLE FIREPLACE
CONSTRUCTED FROM TIMBER AND / OR PLASTERBOARD, THE FLUE 
WILL NEED TO BE SUPPORTED TO MAINTAIN MIN CLEARANCES 
FROM

 

ANY COMBUSTIBLE MATERIALS

.

           

THE HEATER MUST BE INSTALLED WITH IT’S INTEGRAL FLUE 
CORRECTLY INSTALLED (SEE INSTALLATION INSTRUCTION BOOKLET)
FOR THIS HEATER TO OPERATE PROPERLY. IF THE FLUE SYSTEM
IS NOT CORRECTLY INSTALLED AND MAINTAINED, POISONING BY
CARBON MONOXIDE (CO) COULD RESULT AND POSSIBLY CAUSE
DEATH.

THE APPLIANCE SHOULD BE INSPECTED PRIOR TO USE, WITH 
REGULAR INSPECTIONS (ANNUALLY) TO BE MADE BY A LICENSED 
SERVICE PERSON. IT IS IMPORTANT THAT CIRCULATING AIR 
PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN, DIRT AND LINT 
FREE, FOR A SAFE AND EFFICIENT OPERATION OF THE HEATER. 

SAFETY WARNINGS

MAINTENANCE

IF YOUR HEATER REQUIRES ATTENTION CONTACT:

SAMPFORD AND STAFF PTY LTD

ON

PH 1300 727 421

FAX 1300 727 425   

Page 8.

Содержание FFITZROY PROFILE PWR

Страница 1: ...WR TO SUIT MOCK FIREPLACE INSTALLATIONS INSTALLATION INSTRUCTIONS FOR FITMENT INTO A COMBUSTIBLE ENCLOSURE This heater is for use with Natural Gas Read these instructions in conjunction with heater in...

Страница 2: ...ge 1 a CLEARANCE FROM COMBUSTIBLE P ge a 2 OVERALL DIMENSIONS OF CABINET P ge a 3 5 Pa 4 ge FITMENT OF SPACER BRACKETS AND BLANKET CAVITY CLEARANCE REQUIREMENTS Page 6 7 INSTALLATION DETAIL ADVICE P g...

Страница 3: ...LING THIS POWER FLUE HEATER INTO A MOCK FIREPLACE A MOCK FIREPLACE INSTALLATION KIT MUST BE USED FOR INSTALLATION INTO A MOCK COMBUSTIBLE FIREPLACE CONSTRUCTED FROM TIMBER AND OR PLASTERBOARD THE FLUE...

Страница 4: ...IBLES BETWEEN HEATER CABINET AND OTHER COMBUSTIBLE SURFACES 50 mm CLEARANCE FROM BOTH TOP AND SIDE SURFACES 50 mm CLEARANCE FROM REAR 50 mm CLEARANCE BETWEEN SIDE OF THE HEATER FRONT AND COMBUSTIBLES...

Страница 5: ...m WIDTH 735 mm DEPTH 430 mm 625 mm 430mm THE HEATER FOR INSTALLATION INTO A MOCK FIREPLACE IS SUPPLIED WITH THE FOLLOWING PARTS F1404 REAR BRACKETS F1405 TOP SIDE SPACER BRACKETS F1406 INSULATION BLAN...

Страница 6: ...ETS 1 THE SPACER LOCATION ARE MARKED ON THE HEATER CABINET INSERT SEE FIG 4 2 REMOVE THE FIXING SCREWS NEXT TO THE SHADED SECTIONS MARKED ON THE HEATER CABINET INSERT SEE FIG 4 FIG 4 FOR MOCK INSTALLA...

Страница 7: ...ONS USING EXISTING SCREW POSITIONS 4 FIT REAR SPACER BRACKETS TO HEATER CABINET ON DIAGONAL CORNERS AS SHOWN SEE FIG 5 SEE FIG 5 FLUE ENTRY FIXING SCREWS No8 x 3 8 SELF TAPPING REAR BRACKET TOP SIDE B...

Страница 8: ...N INTO A COMBUSTIBLE ENCLOSURE USING A MOCK FIREPLACE KIT Pt No F3084 SEE FIG 6 CEILING MANTLE 300 MIN 1000 MIN CLEARANCE 380 485 605 650 MIN 440 MIN 695 50 50 795 MIN PLAN VIEW SIDE VIEW 160 mm GAS S...

Страница 9: ...INSTALLATION DETAIL Page 7 REFER TO THE INSTALLATION BOOKLET SUPPLIED WITH THE HEATER...

Страница 10: ...MAINTENANCE IF YOUR HEATER REQUIRES ATTENTION CONTACT SAMPFORD AND STAFF PTY LTD ON PH 1300 727 421 FAX 1300 727 425 Page 8...

Страница 11: ...NOTES 5 Page 9...

Страница 12: ...REF F3084 C REVISION C DATED FEB 2007...

Отзывы: