6
Operating instructions
1. Plug the power cord into the wall socket and turn on the power to the
heater, see figure 1. Refrain from using an extension cord.
User instructions
1
19
2. For control lay-out refer to figure 2
2
ON/OFF button
When there is power to the heater but it is on
standby mode a red LED will blink
intermittently behind this button.
To turn heater on press the ON/ OFF button.
There will be a 5 second delay before the
burner ignites. At this setting the burner is on
low flame / low fan for 3 minutes. During the
ignition process the red LED will glow.
The red LED will fade out after 30 seconds
when the ignition process is complete.
Pressing the heat setting buttons will set the
heater to HIGH , MEDIUM or LOW heat.
The fan is set to a corresponding speed for
each setting.
To turn the heater off press the ON OFF
button.
If the burner fails to ignite, wait 20 seconds
and then press the ON OFF button.
In case of power failure, when the power
returns, wait 20 seconds for any unburnt gas
to vent and start reignition by pressing the ON
OFF button.
ON / OFF
LOW
MEDIUM
HIGH
Service instructions
(Do not modify this appliance)
General
1. Service work to be carried out by an authorised service person only.
2. Unplug from wall socket or turn off power at main switchboard if heater
is hard wired.
3. Always shut off the gas supply and ensure that the heater is cool before
commencing any service operations.
4. Always check for gas soundness after servicing.
To replace the primary glass
1. Refer pages 13 and 14, steps 7 to 11, of the installation instructions.
Refit glass and replace in reverse order ensure the inside surface of the
glass is clean and free from finger marks.
To replace the outer glass
1. Remove the outer glass, refer page 13, fig 15.
2. Loosen bottom glass frame and remove top glass frame.
3. Replace glass and refit in reverse order.
Note: ensure the inside surface of the glass is clean and free from finger
marks.
To replace the gas control
1. Remove the lower front cover by unscrewing two M5 screws through
the air intake slot. Refer page 13, figure 16, of the installation instructions.
2. Unplug the cables from the gas control and disconnect the earth connection.
3. Disconnect the gas inlet (1/2” compression nut) connection at entry
gas control and the 16mm nut at the outlet of the gas control.
4. Remove the three M3 screws from the cradle retaining the gas control.
5. Remove gas control.
6. Replace gas control in reverse order and check for gas tightness
Note: check the gas pressure on high and low burner settings. Refer ‘gas control’,
pages 13 and 14
To replace the ignition (module) device
1. Unplug wire connectors from ignition module.
2. Remove module mounting bracket by removing
mounting screw.
3. Using pliers bend tabs so that module can come
away from the mounting bracket.
4. Replace ignition device in reverse order.
Ignition module
Mounting bracket