6. Prepare electrical and gas connections. Remove the lower front cover,
see figure 16. A 10 Amp wall socket needs to be located within 1.5m
of the heater. If using a power point in the chimney, route the plug and
cord through cord access at lower LH side of rear panel.
A grommet is fitted over the cord. Ensure that the grommet is located
over the edges of the access hole. Refer figure 14.
Hard (fixed ) wiring connection is to be carried out only by a qualified
electrician.
7. To remove the inner fascia assembly undo two screws in the upper
flange as indicated in fig 15a
. Remove the inner fascia assemblyby holding the glass surround firmly
pull it towards you. see fig 15 b
8. Remove the lower front cover by
unscrewing two M5 screws through t h
e air
intake slots, see figure 16.
If unit is fitted with supply flexible cord
ensure that the cord cannot be trapped
when the heater is installed.
9.To remove the front heater surround undo two s/t
screws (one either side) from the bottom flange of the
front panel as indicated in figure 17.
Remove the surround by pulling the lower section towards
you gently to partly disengage it from the body of the
heater, then gently lift it vertically to completely disengage
it. Refer figure 18.
14
15a
16
17
10. To fully remove the fascia, unclip the
switch cable from the pcb connector and
unclip the cable from the clipping points.
The cable is routed through a plastic
grommet which will have to be removed
from the base plate.
Grommet
11. Remove the inner glass. Slacken off screws in top clamp and remove
side clamps. Refer figure 20.
Sealing
12. All gaps between heater case
and fireplace are to be sealed.
Seal with foam tape around
top and sides of heater flange
as required. Refer figure 21.
Seal with fibreglass between
bottom of heater case and
base of fireplace.
DO NOT SEAL WITH SILICON.