If you have changed the type of gas, it is
important to verify the flame stability at the
minimum regulation.
“Gaing Access to the by-pass screw”
To gain access to hob burner by-pass screws,
remove the knobs from the control panel.
Never loosen the others screws!
23
•
These hobs are delivered with cable.
•
Connection is exclusively envisaged under tensions
of 220-240V. Between phases or between phases
and neutral.
•
Connect 10/16 amperes to an outlet.
•
The eventual replacement of the supplying cord
must be carried on by the After Sales Service or by an
agreed engineer, with a cord whose characteristics
must be similar to the original one:
•
For the 4G hobs supplying cord type H05VV-F
(section 3G 0.75mm )
•
For the 3G+E hobs, the rated current is 8.6A.
Supplying cord type H05VV-F (section 3G 1mm )
•
For the 2G+2E hobs, the rated current is 13.6A. Supplying cord type H05VV-F (section 3G
1.5mm )
2
2
2
GAS and MIXED
Ground cable (Green-Yellow)
Phase cable
Neutral