TABLE FOR THE CHOICE OF THE INJECTORS
BURNERS
Nominal Power Reduced Power
LPG (PROPANE/
BUTANE)
5 kPa
[g/h]
[kW]
[g/h]
[kW]
Ø injector
[1/100 mm]
Auxiliary (A)
73
1,00
25
0,34
46
Semi-rapid (SR)
122
1,68
36
0,50
58
Rapid (R)
219
3,00
73
1,00
79
Double-ring compact (MW)
255
3,50
109
1,50
85
Double-ring (DCS)
277
3,80
116
1,60
90
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,36
Rapid (R)
6,00
Double-ring compact (MW)
7,00
Double-ring (DCS)
7,60
GAS MAINTENANCE
LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation, maintenance and conversion of the appliance
must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.