18
18
LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation, maintenance and conversion of the appliance
must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
TABLE FOR THE CHOICE OF THE INJECTORS
Cat: II 2H 3+
(Countries IT-ES-PT-IE-GB-CH)
G30/G31
28-30/37 mbar
G20
20 mbar
Cat: II 2E+3+
(Countries FR-BE)
G30/G31
28-30/37 mbar
G20/G25
20/25 mbar
BURNERS
Nominal
Power
[kW]
Reduced
Power
[kW]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Auxiliary (A)
1,00
0,40
50
77
Semi-rapid (SR)
1,75
0,45
66
101
Rapid (R)
2,50
0,75
80
118
Double-ring compact (DRC)
3,50
1,50
92
139
Double-ring (DR)
3,50
1,50
93
135
Dual (DB) - inner crown
0,80
0,40
46
70
Dual (DB) - outer crown
3,40
1,50
65 (x2)
95 (x2)
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,50
Rapid (R)
5,00
Double-ring compact (DRC)
7,00
Double-ring (DR)
7,00
Dual (DB) - inner crown only
1,60
Dual (DB) - outer crown only
6,80
Dual (DB) - inner & outer crown
8,40
Some models - for the gas category check the data label attached on the appliance
Содержание CVG6PX LPG
Страница 7: ...7 7 ADVICE ADVICE for the for the INSTALLER INSTALLER...
Страница 23: ...23 23...
Страница 24: ...24 24 ADVICE ADVICE for the for the USERS USERS...
Страница 34: ...34 34 Fig 2 8...
Страница 40: ...40 40 A B Fig 3 7 Fig 3 8 Fig 3 6 MODELS WITH DUAL BURNER T T S S...
Страница 42: ...42 42...
Страница 43: ...43 43...