Before making the connection, make sure that the installation is
protected by a suitable fuse, and that it is fitted with wires of a large
enough section to supply the appliance normally.
Turn over the hob, glass side against the working top, taking care to
protect the glass.
Three Phase 220-240 V3
It is however possible to connect the hob to:
Three Phase 380-415 V2N
To proceed to the new connection, please follow below instructions:
Open the cover in the following sequence:
If the hob is fitted with power supply cord, this shall be connected only
to a power supply of 220-240 V between phase and neutral.
For any questions regarding power supply cord refer to After Sales
Service or a qualified technician.
Manufacturer declines all responsibility for any damage that
might be caused by unsuitable or unreasonable
use.
The electrical connection to the installation should be made according
to the rated power of the Appliance; this should be made via an Omni
pole cut-out switch.
"Installation must conform to the standards
& directives."
WARNING: Manufacturer cannot be held responsible for any incident
or its consequences that may arise during the use of an appliance not
linked to the earth, or linked to an earth whose continuity is defective.
Before any electrical operation, please check the supply tension
shown on the electricity meter, the adjustment of the circuit- breaker,
the continuity of the connection to earth to the installation and that the
fuse is suitable.
If the appliance has a socket outlet, it must be installed so that the
socket outlet is accessible.
The yellow/green wire of the power supply cable must be connected to
the earth of both power supply and appliance terminals.
2
3
1
- Pass the power supply cable into the clamp;
- Remove the screws retaining the terminal block which
contains the shunt bars and the conductors of the supply cord;
- Choose the power supply cable in accordance with the
recommendations in the table;
- remove the cover.
- unscrew the cable clamp
"1";
- According to the installation and with the help of shunt bars which you
should have recovered in the first operation, fix the conductor as
shown on the chart;
To release the power supply cord:
- put the blade of a flat screw-driver in front of each tab "2" e
"3", push in and press;
- find the two tabs located on the sides;
- Pull out the supply cord.
Operations to be carried out to make a new connection:
- Screw the cable clamp.
- Strip the end of each conductor of the supply cord on a 10 mm length,
by taking in account the requested length of the cord for the
connection to the terminal block;
- Fix the cover;
N = Neutral
T = Earth
Monophase 220-240 V~
Two phases 220-240 V2~
Three phases 220-240 V3~
Three phases 380-415 V2N~
Ph = Phase
Connection to the terminals on the terminal block
ATTENTION:
If it should be necessary to replace the power supply cord, connect the
wire in accordance with following colors/codes:
LAY OUT
"1-6"
LAY OUT
"7"
MONOPHASE or TWO PHASES 220-240 V
~
Cable
HO5V2V2F
Cable
HO5V2V2F
Cable
HO5V2V2F
3x2,5 mm
2
3x4 mm
2
4x1,5 mm
2
4x1,5 mm
2
4x1,5 mm
2
4x1,5 mm
2
THREE PHASES 220-240 V
3~
THREE PHASES 380-415 V
2N~
- According to the installation and with the help
of shunt bars which you should have
recovered in the first operation, fix the
conductor as shown on the chart;
- Strip the end of each conductor of the supply
cord on a 10 mm length, by taking in account
the requested length of the cord for the
connection to the terminal block;
- Choose the power supply cable in accordance with the
recommendations in the table;
Note: make sure the terminal board screws are tight.
Operations to be carried out to make a new connection:
- Pass the power supply cable into the clamp;
- Fix the cover;
- Screw the cable clamp.
07 GB