3:0. DISARMING THE SYSTEM

Enter the protected area by the authorised entry route. A single continuous

tone is made from any extension speakers and from any remote keypads

fitted. Proceed directly to the control panel or keypad and insert your user

code whereby the system disarms. If the entry tone changes to rapid pips,

then you have less than 10 seconds to disarm the system.

4:0. TAMPER FAULTS

Your control panel is equipped with a common tamper circuit giving protec-

tion from unauthorised handling. If the tamper circuit is broken during any

unset period, the internal sounder triggers and the tamper light illuminates.

Proceed directly to the panel or any remote keypads and insert your user

code. The internal sounder stops and reverts to a low two-tone sound. Press

#

 and the panel resets. If the tamper light continues to flash, then the cause

of the tamper condition is still present. (Refer to fault clearing, Section 13:0.)

4:0. DISARMING AFTER AN ALARM

4:0:1. After the Panel Has Auto Reset

Enter the protected area by the authorised entry route. An intermittent tone is

made from the speaker. Proceed directly to the control panel or keypad and

insert your user code. The system disarms and the zone(s) light on the

control panel to indicate the cause of the alarm. (Refer to panel reset,

Section 12:0, to clear the panel.)
The first to alarm shows a constantly illuminated light.

Subsequent alarms are shown as fast flashing lights.

Zones that were isolated are shown as slow flashing lights.

4:0:2. While the Panel Is in Alarm

Go directly to the control panel or remote keypad and insert your user code.

The system disarms and the zone(s) light on the control panel to indicate the

cause of the alarm. (Refer to panel reset to clear, Section 12:0.)
The lights follow the same descriptions as above in Section 4:0:1.

5:0. PERSONAL ATTACK

If your system has a personal attack button fitted, this is linked into the alarm

system as a 24hr device. This means the PA button is live all the time. If the

PA is pressed, all the sounders operate and bring up the zone light pro-

grammed as PA. Proceed directly to the panel or any remote keypads and

insert your user code. The sounders stop and revert to a low two-tone

sound. Press 

#

 and the panel resets. If the zone light continues to flash,

then the cause for the personal attack condition is still present. Go to the

personnel attack button(s) and reset with the special key provided. The zone

light should go out. If the light continues to flash, refer to fault clearing

(Section 13:0).

Note:

 If the panel is armed and a PA is activated, you need to disarm the

system as explained in Section 4:0.

DISARMING

TAMPER

DISARMING
AFTER AN
ALARM

PERSONAL
ATTACK

Содержание SECURIT ST800L+

Страница 1: ...USER MANUAL SECURIT 800L CONTROL PANEL ST800L...

Страница 2: ...ARDS This unit conforms to ECD 89 336 EEC and LVD 73 23 EEC This unit has been tested to the required standards for emission immunity and LVD regulations as set out by the EEC This unit complies with...

Страница 3: ...nes pre programmed to be isolated start to flash Any extension speakers and any remote keypads emit a low pitch continuous tone Provided night set is selected within 5 seconds the exit sounder remains...

Страница 4: ...icate the cause of the alarm Refer to panel reset Section 12 0 to clear the panel The first to alarm shows a constantly illuminated light Subsequent alarms are shown as fast flashing lights Zones that...

Страница 5: ...changing it After you have successfully changed and memorised the code destroy the written code Remember try not to use obvious codes such as the current year To change user code 1 from the panel or...

Страница 6: ...iggered or contact opened the internal sounder gives a loud pulse and the zone light illuminates Clear the detector or close the contact and the sound reverts back to the single pitched sound Proceed...

Страница 7: ...ogs but is silent whilst viewing the UNSET logs Pressing the 0 key while reviewing the logs shows the last alarm event that occurred even if the panel has been set many times Pressing the key changes...

Страница 8: ...to pulse after exit Zone in Fault Check for open doors or a detector is in fault Call your installer Alarm triggers on exit Timer ran out Go quicker to exit or call your installer to extend exit time...

Отзывы: