tone will be given and your old code will still be valid. Start again and enter a
different four digit code.

NOTE: 

If you require user codes 2,3 or 4 enabled you must make sure user

code 1 is NOT set  at 1 2 3 4. If the master code is reset to 1 2 3 4, user
codes 2, 3 and 4 will be removed.

4.4 WALK TESTING THE CONTROL PANEL

Walk testing is a way of testing that the zones of the panel are working
correctly without the need to actually creating an alarm condition. Walk
testing should be performed on a regular basis of say once a month to ensure
problems are quickly spotted.

Enter the four digit user code, the buzzer will emit a steady sound and

the exit time will start.  Press the * key followed by the 9 key, then press the 4
key. The buzzer will emit a low level steady tone. DO NOT TEST PA
BUTTONS AS THESE WILL CAUSE AN ALARM CONDITION.

As you test each device the internal sounder will give a loud pulsing

tone to indicate the correct operation of that device. The LED relating to that
zone will light. When the device test is over the sounder will stop and the
zone LED will go out. The buzzer will emit a low level steady tone  as before.
Report any faults to your Installer..

Press the * key to finish.

4.5 REVIEWING THE ALARM LOGS

The logs are organised as 'SET' and 'UNSET' events. All events are

recorded. The first alarm is shown by the relevant LED being lit continuously.
Subsequent alarms are shown by a fast pulse of the zone LED. Any zones
isolated are shown by a slow pulse of the zone LED. The buzzer will sound
whilst viewing the 'SET' logs but will be silent whilst viewing the 'UNSET'
logs.

Pressing the # key will change between viewing the 'SET' and 'UNSET'

logs. This may be done at any time. The log review will automatically end
after 15 seconds if no keys are pressed.

Enter the four digit user code, t he buzzer will emit a steady sound and

the exit time start. Press the * key followed by the 9 key, then press the 3 key.
The log routine will start viewing 'DAY' 1 'SET'

KEY

 VIEW

 1

LOG 1

 2

LOG 2

 3

LOG 3

 4

LOG 4

 5

LOG 5

 6

LOG 6

Содержание Securit 703

Страница 1: ...SECURIT 703 USER MANUAL C K Systems Ltd THE SECURIT 703 USER INSTRUCTIONS VERSION 1 4 September 1996 C031 111 03...

Страница 2: ...for full set as above Then press the key followed by the 0 key The buzzer will change tone and the LED s for any zones programmed to be isolated in night set will flash The programmed Night set exit t...

Страница 3: ...two tone alternating sound to indicate that there is a RESET REQUIRED Press the key to reset the system The green LED at the top left hand side of the keypad display is the Mains healthy light If thi...

Страница 4: ...our four digit user code the buzzer will emit a steady sound and the exit time start Press the key followed by the 9 key The exit buzzer will stop and all LEDs will light After the 10 Second LED test...

Страница 5: ...one to indicate the correct operation of that device The LED relating to that zone will light When the device test is over the sounder will stop and the zone LED will go out The buzzer will emit a low...

Страница 6: ...ENGINEERING MODE DAY YELLOW PANEL SET PANEL UNSET N A FAULT YELLOW BATTERY OK BATTERY FAULT THERE IS STILL A BATTERY FAULT OR CALL ENGINEER YELLOW LINE OK LINE FAULT OR FAILURE TO COMMUNICATE THERE IS...

Страница 7: ...then unset again The following is given so a record of your zone configurations can be made simply fill in where each zone is located in your premises Also you can fill in any relevant contact numbers...

Страница 8: ...7 C K Systems Ltd Unit 24 Walkers Road North Moons Moat Industrial Estate Redditch Worcs B98 9HE Tel 44 0 1527 68111 Fax 44 0 1527 68222 email info cksys co uk http users powernet co uk cksys...

Отзывы: