![C&H M 2 2 0 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/candh/m-2-2-0/m-2-2-0_user-manual_3070834014.webp)
8
3.1.3
ID EEPROM
The EEPROM holds sixty-four 16-bit words of M-Module ID data and VXI M-Module data.
Refer Section 3.2.3 for more details.
3.1.4
Row and Column Drivers
The module uses a matrix drive scheme (rows and columns) in which a maximum of four of the
relays (one row) can be operated at any one time. An on-board timer (part of Module Control
block) ensures the relay coils have been driven long enough for the contacts to move and settle.
The Row Driver block translates the ROW_SET(4:1) and ROW_RESET(4:1) command lines
from the Module Control block into bipolar and tri-state capable buffered drive signals. The
ROW_DR(4:1)
signals provide either current source from the +5VDR supply (relay set), current
sink to ground (relay reset), or tri-stated output (both current-source and current-sink off). Each
output is tri-stated whenever that particular row is not being driven.
The Column Driver block translates the COL(4:1)
command lines from Module Control into the
bipolar buffered drive signals, COL_DR(4:1). The COL_DR(4:1) signals provide either current
source from the +5VDR
supply (relay reset) or current sink to ground (relay set).
3.1.5
Driver Power Switch
This block removes all power from the Row and Column Driver circuitry except when needed to
move relays. This FET switch is open at power-up to prevent any relay contact movement until
register writes cause drive-power to be applied.
3.1.7 Relay Coils
This block contains the 16 relay coils arranged as a 4x4 matrix. To close a relay, a ROW_DR line
sources current while a COL_DR line sinks current to ground. To open a relay, a COL_DR line
sources current while a ROW_DR line sinks current to ground. Refer to Figure 3 for switching
schematic.
3.1.8 Reset and Power Conditioning
This block filters +5V power to produce VCC power (+5V) for logic and isolates the various
grounds used by the module. This block also processes the /RESET signal from the Carrier
Interface and monitors power to produce the /RST reset signal for the module.
C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, Texas 78681 <> www.chtech.com
Содержание M 2 2 0
Страница 10: ...4 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...
Страница 24: ...18 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...
Страница 26: ...A 2 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...
Страница 27: ...N O T E S C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...
Страница 28: ...C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...