background image

 

 

 

 

Clean and care

 

Caution

 

Disconnect the power supply before cleaning air conditioner, or it may cause electric shock.

 

Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an

 

electric shock.

 

Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a

 

dry soft cloth, or a cloth slightly moistened with water or cleanser.)

 

Clean the air filter (Recommended once every three months)

 

NOTE: If dust is much more around the air conditioner, the air filters should be cleaned many times. 
After taking off the filter, don't touch the fin of indoor unit, in order to avoid hurt your fingers.

 

① 

Take down the air filter

 

At the slot of surface panel to open an angle, pull the air filter 

downward and take it out, please see the Fig. 4(a, b).

 

(a)

 

(b)

 

② 

Clean the air filter

 

T

o clean the dust adhering to the filters, you can either 

use a vacuum cleaner, or wash them with warm water 
the water with the neutral detergent should below 45 
degree) ,and dry it in the shade.

 

NOTE: Never use water above 45

℃ 

to clean, or it can 

cause deformation or discoloration. Never parch it by 
fire, or can cause a fire or deformation.

 

Fig.4

 

③ 

Insert the air filter

 

Reinsert the filters along the direction of arrowhead, and 
then to cover the cover and clasp it.

 

10

 

 

 

 

 

 

 

   

 

 

 

 

Clean the front panel

 

When cleaning the front panel, please dip the cloth into the water temperature of 45

℃ 

below, then to dry 

the cloth and wipe the dirty part.

 

Note: Please do not to immerse the front panel in water, due to there are microcomputer components and 

circuit diagrams on the front panel.

 

Clean the air filter (Recommended once every three months)

 

Содержание COZY SERIES

Страница 1: ...eep it for further reference OWNER S MANUAL MANUAL C H AIR CONDITIONERS Thank you for selecting С H air conditioners Please read this manual carefully before operation and keep it for further reference Split Air Conditioner COZY SERIES MODELS CH S07LH R2 CH S09LH R2 CH S12LH R2 СH S18LH R2 CH S24LH R2 ...

Страница 2: ...n with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do not dispose this product as unsorted municipal waste Collection of such waste separately for spec...

Страница 3: ...e about 5 degree It can preclude the electricity wasted Don t leave windows and doors open for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the air conditioning capacity or cause a malfunction Keep combustible spray away It can cause afire or explosion Pl...

Страница 4: ...long time It can cause the health problems Don t use the air conditioner for other purposes such as drying clothes preserving foods etc Splashing water on the air conditioner can cause an electric shock and malfunction Don t place a space heater near the air conditioner Or CO toxicosis may occur for imcomplete The airflow direction can be adjusted appropriately At operating adjust the vertical air...

Страница 5: ... capacity will be reduced due to outdoor temperature decrease If outdoor temperature becomes very low please operate with other heating equipments Defrosting When outdoor temperature is low but high humidity after a long while running frost will form on outdoor unit that will effect the heating effect at this time the auto defrosting function will act the heat running will stop for 8 10mins During...

Страница 6: ...the starting condition 2 In Heat mode the temperature arrive at the setting value and the compressor stop running about 1min The operating temperature range outdoor temperature for cooling unit is 21 43 for cooling and heating unit is 7 43 4 Working temperature range Indoor sideDB WB o C Outdoor sideDB WB o C Maximum cooling 32 23 43 26 Minimum cooling 21 15 21 Maximum heating 27 24 18 Minimum hea...

Страница 7: ... out The pattern in displayer Cool Dry Heat Run Set temp Wireless remote control Air in Air out 5 Outdoor unit Indoor unit 1 Power cable 2 Remote control 3 Front panel 4 Filter 6 Wall pipe 5 Guide louver 7 Bind tape 8 Connection 9 Drainage pipe ...

Страница 8: ... pressing this key you may select AUTO FAN 1 FAN 2 FAN 3 or FAN 4 and may also cycle between them FAN 4 only in cool or heat mode After being energized AUTO is defaulted Only LOW fan can be set under DRY mode pressing this key can not adjust the fan speed but can send message Fan 1 Fan 2 Fan 3 Fan 4 ON OFF button Press this button the unit will be turned on press it once more the unit will be turn...

Страница 9: ...to switch on the unit and cancel the auto switch on When the temperature display becomes constant you may press this key again to display the remaining set time The time value T On and H will display constantly for 2 seconds After 2 seconds the preset temperature will be displayed Within these 2 seconds you may press this key again to cancel the auto switch on and send the message By pressing this...

Страница 10: ...le running method and to make ambient comfortable About LOCK Under switch on or switch off state you may hold and key simultaneously to lock and unlock the keypad When locked the display will show the LOCK icon in which case the lock icon will flash three times upon operation of any key After the keypad is unlocked the lock icon on the display will be hidden After being energized the default is un...

Страница 11: ...eration should be in its receiving range It should be placed at where is 1m away from the TV set or stereo sound sets If the wireless remote control can not operate normally please take them out after 30s later and reinsert if they cannot normally run please change them Fig 2 Emergency operation If the wireless remote control is lostor broken please use the manual switch button At this time the un...

Страница 12: ... angle pull the air filter downward and take it out please see the Fig 4 a b a b Clean the air filter To clean the dust adhering to the filters you can either use a vacuum cleaner or wash them with warm water the water with the neutral detergent should below 45 degree and dry it in the shade NOTE Never use water above 45 to clean or it can cause deformation or discoloration Never parch it by fire ...

Страница 13: ...whether the installation stand of the outdoor unit is damaged or not If damaged please contact the dealer Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies Clear dust and obstructions from the outdoor unit Repaint the rubiginous place on the outdoor unit to prevent it from spreading Adopt the special shield to cover the outdoor unit avoid the rain water du...

Страница 14: ... the smell accumulated in the ambient Solution method Cleaning the filter If problem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is running the compressor started or stopped running or the unit is stopped sometimes there is swoosh or gurgle the sound is ...

Страница 15: ...insert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leakage in the room The air humidity is on the high side Condensing water over flowed The connection position of indoor unit drainage pipe is loosed If water leakage in outdoor unit When the...

Страница 16: ...n the temperature of indoor heat exchanger is very low that will stop deliver air in order to prevent cool air Within 2min In HEAT mode when the outdoor temperature is low or high humidity there are much frost be formed on the outdoor heat exchanger that the unit will automatically defrost indoor unit stop blowing air for 3 12min During the defrosting there is water flowing out or vapor be produce...

Отзывы: