API 6D Two - Piece

 

Cast Trunnion  

Mounted Ball Valve  

Atlas Series 

 
Document Number: 

Revision: 

Release Date:               

 

EDC 506 

01/03/2018 

 

 

 

 

 

 

 

IOM: Installation, Operation and Maintenance Manual

 

 

                

14/17

 

For either gear operated valves or actuated valves, make sure that both the travel ends act when 
the valve is fully open and closed. 
 

7  PROPER VALVE TESTING  

Always  perform  an  API  6D  pressure  test  before  re-installing  the  valve  into  the  line  to  verify  that  the 
maintenance operation have been satisfactorily performed and to re-certify pressure containment capability 
of the valve. 
 
 

 

 
 
 

7.1 SHELL TEST 

There shall not be any leakage under the pressure when ball is partially open and both ends are blanked. 
Testing  pressure is  1.5 times the maximum  operating  pressure. Test  duration are  2min for  4”  and under 
valves, 5mi

n for 6” to 10” valves, 15min for 12” to 18” and 30min for 20” and larger. 

(a)  Fit the vent valve and set it in open position. 
(b)  Operate the valve to the half-open position. 
(c)  Fill in the valve with the fluid (Venting the air through the vent valve) 
(d)  Close  the  vent  valve  and  apply  pressure  in  accordance  with  maximum  operating  pressure  of  the 

pipeline. 

(e)  Visually check the outside of the ball valve for leakage. 
(f)  Depressurize the valve. 

 

7.2 HYDROSTATIC SEAT TEST 

Valves are to be subjected to a hydrostatic seat test. There is to be no leakage under test pressure. Test 
pressure  is  to  be  applied  to  the  appropriate  end  of  the  valve.  Testing  pressures  1.1  times  maximum 
operating pressure. Test durations are 2

min for 4” and under valves, 5min for 6” to 18” and 10mim for 20” 

and larger valves. 

(a)  Operate the valve to the fully close position and open the vent valve. 
(b)  Pressurize one side in accordance with max operating pressure of the pipeline. 
(c)  From the body vent or bleed fitting, check for possible seat leakage. 
(d)  Repeat same operations as per points (b) & (c) on opposite side of the valve. 
(e)  Depressurize the valve. 

 

7.3 DOUBLE BLOCK AND BLEED (DBB) TEST 

If the valve seats have DBB function, then the seat test shall be performed as follows: 

(a)  With the valve unseated and partially open, the valve cavity shall be completely filled with test fluid. 
(b)  The valve shall then be closed and the vent valve opened to allow excess test fluid to overflow form 

the valve 

– cavity test connection. 

(c)  The test pressure shall be applied simultaneously from both ends. 
(d)  Seat tightness shall be monitored from the cavity connection. 
(e)  Depressurize the valve. 

 

Installing the valve in the line without pressure testing could cause leakage 
of production fluid and, potentially hazardous situation. 

Содержание Atlas Series

Страница 1: ...Valve Atlas Series Document Number Revision Release Date EDC 506 0 01 03 2018 IOM Installation Operation and Maintenance Manual 1 17 Installation Operation and Maintenance Manual API 6D Two Piece Cas...

Страница 2: ...4 1 INITIAL START UP COMMISSIONING 8 4 2 NORMAL OPERATING ACTIVITY 8 4 3 DOUBLE BLOCK AND BLEED OPERATION 8 4 4 BODY CAVITY RELIEVING SYSTEM 9 5 MAINTENANCE 9 5 1 VALVE MAINTENANCE IN OPERATION 9 5 1...

Страница 3: ...hase order requirements Correct type pressure class size body trim seal material and end connections This information may be found on the nameplate or may be stamped on the body of the valve Each C C...

Страница 4: ...ting equipment s safe working load SWL shall always be double checked prior to any lift During lifting handling always keep valve flange protection in place to avoid foreign material from entering the...

Страница 5: ...does not take any responsibility unless this requirement has been agreed on the purchase order Lubrication during storage is not recommended 2 BILL OF MATERIAL ITEM Component ITEM Component 1 Body 24...

Страница 6: ...Piece Cast Trunnion Mounted Ball Valve Atlas Series Document Number Revision Release Date EDC 506 0 01 03 2018 IOM Installation Operation and Maintenance Manual 6 17 Figure 2 Atlas Series Ball Valve...

Страница 7: ...ve in system using proper size and type mating flanges and appropriate gaskets for RF or seal rings for RTJ Valve design allows for line flow in either direction The pipeline where the valve is to be...

Страница 8: ...e fitting will prevent accumulated water from freezing It is also advisable to inject a sufficient amount of valve lubricant into the grease fittings of valve and operator if present prior to extended...

Страница 9: ...y must be protected from overpressure by means of a Pressure Relieving Valve PRV set to relieve excess pressure The standard PRV connected to the body cavity has been pre set and tested in the factory...

Страница 10: ...ent valve operation the valve shall be inspected on a regular basis during the operation and subject to scheduled maintenance Qualified person shall do all maintenance work Table 1 Recommended Lubrica...

Страница 11: ...ly open position Always use the safety plug or bleed fitting provided either at the drain connection to release the body cavity pressure Remove the valve from the line Before disassembling the valve i...

Страница 12: ...Remove the stem 4 from the body through end entry Extract the lantern ring 20 from the body 1 through top It is possible to remove the stem injection fitting 38 for cleaning Stem Retaining Pin design...

Страница 13: ...into the body 1 and closure 2 When pressing the seat into the body and closure pay attention that the seat moves correctly parallel to the body and closure surfaces For this operation we recommend usi...

Страница 14: ...l valve for leakage f Depressurize the valve 7 2 HYDROSTATIC SEAT TEST Valves are to be subjected to a hydrostatic seat test There is to be no leakage under test pressure Test pressure is to be applie...

Страница 15: ...7 7 16 416 381 1 5 8 M42 25800 24286 1 2 M12 602 549 1 3 4 M45 32394 27756 9 16 M14 903 841 1 7 8 M48 39607 34695 5 8 M16 1204 1106 2 M52 49210 41634 3 4 M20 2168 2036 2 1 4 M56 71957 61761 7 8 M22 36...

Страница 16: ...ir section 2 Check the gear operator for fully closed position 3 Disassemble the valve and replace damaged component s 4 Disassemble the valve and replace the O Ring Leak around the stem 1 Worn or dam...

Страница 17: ...e installation operation and maintenance of C C Flow Control Atlas Series API 6D two piece trunnion mounted ball valves CNC Flow Control reserves the right to change information contained in this manu...

Отзывы: