Canature 475QC Скачать руководство пользователя страница 5

5  

Installing the Self-Piercing Inlet Saddle Valve  

The self-piercing saddle valve is designed for use with 3/8” to 1/2” OD soft 
copper supply tubing. 

 
1.  Turn off cold water valve from under sink or main water line valve for 

whole house. 

2.  Before installing self-piercing valve, make sure piercing lance does not 

protrude beyond rubber gasket. 

3.  Assemble saddle valve on copper tubing. 
4.  Tighten screw to fasten saddle valve to copper tubing. 
5.  Turn  handle  clockwise  to  pierce  soft  copper  tube  until  valve  is  firmly 

seated.  (Valve is closed in this position). 

6.  Turn on water supply to pressure cold water line and check for leaks. 

Installing the Unit 

When installed under a sink the unit is normally mounted to the right or left sink cabinet sidewall.  It is sug-
gested  to  locate  the  system  where  it  can  be  easily  accessed  or  even  removed  off  the  hanging  screws  and 

pulled back out from the sink to change the filters. 
 

1.  Locate the unit in the desired position.  Make sure it is at least 3” off the floor.  Level it and mark the loca-

tion of mounting screws. 

2.  Install the screws.  Leave 1/4” of the screw head out from the wall. 

3.  Install the mounting bracket slots over the screws and hang the unit. 
 

NOTE:  THE UNIT MUST BE INSTALLED BY HANGING THE BRACKET ON THE WALL SO THAT THERE 
IS NO WEIGHT ON THE FILTERS.  THE SYSTEM IS NOT DESIGNED OR INTENDED TO SIT ON THE 

FLOOR WITH THE WEIGHT SUPPORTED BY THE REPLACEABLE FILTER CARTRIDGES.

 

Figure 2. Self-Piercing Inlet  
Saddle Valve 

Installing Tubing Into Fittings 

Push the tube into the fitting and up to the 
tube stop  

Pull on the tube to check that it is secure. 
Test the system before use. 

Cut the tube square and remove burrs 
and sharp edges.  Ensure that the out-

side diameter is free from score marks.  
For soft or thin walled plastic tubing we 

recommend the use of a tube insert. 

Step 1

 

Step 2

 

Step 3

 

Содержание 475QC

Страница 1: ...ener ON N2E 2C3 U S Head Office 8437 10th Avenue North Golden Valley MN 55427 INSTALLERS PLEASE READ ALL INSTRUCTIONS BEFORE IN STALLING AND USING THIS SYSTEM IT IS RECOMMENDED TO WAIT UNTIL THE ENTIR...

Страница 2: ...tage 2 COC 10 GAC 10 to remove chlorine taste odors very fine particulates Stage 3 UF 10 to reduce lead VOC and fine particles down to 0 2 micron The system is compact and can be installed under the s...

Страница 3: ...ular installation Your Filter system may be installed under the sink in a basement or other location depending on available space It is recommended the system be installed in as close a proximity to t...

Страница 4: ...mall indent at the desired faucet location 2 flat surface is required not exceeding 1 1 4 in thickness Drill the 1 8 pilot hole Drill the hole for the faucet shank to fit through Clean up sharp edges...

Страница 5: ...r even removed off the hanging screws and pulled back out from the sink to change the filters 1 Locate the unit in the desired position Make sure it is at least 3 off the floor Level it and mark the l...

Страница 6: ...e post filter to the faucet as short as practical for good flow Leave enough tubing that the system can easily be pulled out from the cabinet for easy filter changes Procedure 1 Connect tubing from fa...

Страница 7: ...7 THIS PAGE LEFT INTENTIIONALLY BLANK...