Canature WaterGroup 89DF Скачать руководство пользователя страница 10

10

   

 

   

   

  

  

Plug

the

Riser

Tube

The riser 

(distributor) 

remains inside 

the tank 

seated in the 

depression at 

the bottom

1. 

Temporarily plug the open end at the top  

  of the riser (distribution) tube with tape.

2. 

Ensure the bottom of the riser tube remains  

  seated in the depression at the bottom of  

  the tank. Fill tank one-quarter full with  

  water to protect the distribution tube  

  during gravel installation.

3. 

Fill the gravel support bed first.  

  A large funnel makes filling the  

  tank much easier. Order part #99003  

  separately for your own funnel.    

  Slowly add the gravel. Depending on  

  the type of system, add the resin, or  

  media next.

Support Bed
Grave

l

Media

MANDATORY

Wear a Dust Mask.  

Airborne particles could pose 

potential health risks.

PREPARATIONS

MEDIA INSTALLATION (WHEN NECESSARY) 

 

When

 

larger units cannot be loaded due to weight restrictions, media will be shipped  

pre-measured in separate containers. Follow the steps below for proper media loading.

 

NOTE

If severe loss in water pressure is observed when the softener 

unit is initially placed in service, the softener tank may have 

been laid on its side during transit. If this occurs, backwash the 

softener to ‘reclassify’ the media.

Содержание 89DF

Страница 1: ...eration 4 Avoid pinched O rings during installation by applying NSF certified lubricant to all seals provided with install kit 5 This system is not intended for treating water that is microbiologicall...

Страница 2: ...R PARAMETERS 7 UNPACKING INSPECTION 8 BEFORE INSTALLATION 9 PREPARATIONS 10 PLANNING YOUR INSTALLATION 13 INSTALLATION STEPS 16 UNDERSTAND THE SCREEN KEYPAD CONFIGURATION 18 START UP INSTRUCTIONS 19 O...

Страница 3: ...warranty The warranty provided gives you specific legal rights and otherwise limits your legal rights to the extent permitted by law By installing and or using this product you are accepting these li...

Страница 4: ...al number and valve serial number in the Records Contacts section as they will be important if you need to troubleshoot NOTE For cabinet models the model number and the system serial number are locate...

Страница 5: ...or 40 F 110 F Do NOT expose softener to freezing temperatures or vacuum Discharge lines exposed to freezing temperatures should be positioned with a downward slope Do NOT expose softener to direct su...

Страница 6: ...r use is at its minimum Use of water during the regeneration time will result in hard untreated water being used FEATURES TERMINOLOGY Flow Rate It will only display if treated water is running otherwi...

Страница 7: ...tact Information Is displayed when available At the stated service flow rates the pressure drop through these devices will not exceed 15 psig Peak flow rates are intended for intermittent use only 10...

Страница 8: ...rts box until you are ready to use them What is included in the box For Models 075 100 150 200 250 300 you will expect the following 1 Control Valve 2 Pressure Tank 3 Parts Box 4 Brine Tank Assembly 5...

Страница 9: ...them Softener resins will degrade in the presence of chlorine or chloramines above one 1 ppm If you have anything in excess of this amount you will experience reduced life of the resin Carbon filtrat...

Страница 10: ...er part 99003 separately for your own funnel Slowly add the gravel Depending on the type of system add the resin or media next Support Bed Gravel Media MANDATORY Wear a Dust Mask Airborne particles co...

Страница 11: ...5 Remove the tape from the top of the riser tube Carefully position the valve over the riser tube inserting riser into the internal O ring Turn the valve clockwise into the threads of the tank until s...

Страница 12: ...or installation of brine tank at the installation site pull the other end of the brine tube from the hole on the brine tank The completed assembly is below 3 Place the brine grid with the brine well i...

Страница 13: ...hould be located before the water heater on the supply line If closer than three 3 metres 10 feet install a check valve in accordance with local plumbing codes 7 Do NOT install a softener in a locatio...

Страница 14: ...ptional Pipes Fixed Structure Drain Elbow Assembly Outlet BrineTank 3 8 BrineTube Inlet Upflow Valve Outlet Brine Elbow Assembly Bypass assembly Outlet Inlet Drain Elbow Assembly Floor drain Optional...

Страница 15: ...Drain Elbow Assembly Outlet BrineTank 3 8 BrineTube Inlet 5 8 Overflow Line Optional Brine Elbow Assembly Bypass assembly Outlet Inlet Drain Elbow Assembly Floor drain Optional Pipes Fixed Structure...

Страница 16: ...or elbow plumbing adaptors 3 Apply the supplied lubricant 92360 to the O rings of the fittings 4 Connect the supplied straight or elbow plumbing adaptors to the bypass with red clips 5 Connect the inl...

Страница 17: ...ervice OPEN the bypass valve by rotating the knobs back to the SERVICE position NOTE Please make sure bypass knobs are completely open otherwise the untreated water may enter through the valve INSTALL...

Страница 18: ...position as shown below The control valve is controlled with simple user friendly electronics displayed on an LCD screen Connect theTransformer Connect the transformer to the unit by plugging the 12...

Страница 19: ...tank cabinet salt lid and fill with water until there is approximately 1 25 4 mm of water above the grid plate 2 If there is no grid plate fill the tank with 3 75 mm of water Do NOT add salt to the br...

Страница 20: ...e Press button three 3 to Confirm 3 Setting complete 1 Press and hold button one 1 the display will read PRESS 5 Seconds to Unlock 2 After 5 seconds the display will beep confirming unlock 3 Press but...

Страница 21: ...per gallon of the raw water supply It is used to calculate the system capacity If Ferrous Iron is present add 4 gpg for every 1 ppm of Ferrous Iron This unit is factory set for the correct size You a...

Страница 22: ...s To Cancel Press To Confirm 1 Press buttons two 2 or four 4 to select Manual Regen Press button three 3 to Confirm 1 Press buttons two 2 or four 4 to select Dealer Information Press button three 3 to...

Страница 23: ...ress buttons two 2 or four 4 to select Advanced Menu Press and hold button three 3 for five 5 seconds to enter 1 3 2 4 Advanced Menu BacklightSettings HistoryValues SaltReminderSet AlarmOption BrinePr...

Страница 24: ...s button three 3 to enter 8 Select the time of day for the salt reminder alarm to sound Press buttons two 2 or four 4 to select a number Press button three 3 to advance to the next position 1 3 2 4 Sa...

Страница 25: ...e display will read PRESS 5 Seconds to Unlock 2 After 5 seconds the display will beep confirming unlock MANDATORY Programming changes are necessary to compensate for the injector conversion CAUTION DO...

Страница 26: ...the water heater OFF and shut the heater inlet water valve OFF 2 Drain hot water tank completely OPEN the InletWaterValve allowing the heater tank to be refilled with iron free water Continue flushin...

Страница 27: ...requency Maintenance materials Please see Common Spare Parts CARE OF YOUR SOFTENER To retain the attractive appearance of your new water softener occasionally clean it with a mild soap solution Do NOT...

Страница 28: ...ions happen or the unit fails to regenerate for any other rea son correct the problem first then regenerate the unit manually Regener ate two times in a row to restore the reserve capacity and bring t...

Страница 29: ...er and drill 1 Measure 2 inches from the top of the tank beside the oblong molding 3 Install the holder 5 Take off the small hole cover on the BrineWell lid 4 Hang the Res Care bottle on the hanger 6...

Страница 30: ...SERVICING YOUR CONTROL VALVE BEFORE SERVICING YOU WILL NEED TO 1 Shut the water supply to the softener OFF put the softener into the BYPASS position 2 Relieve water pressure in the softener by steppi...

Страница 31: ...nd put back in 5 Replace seal and spacer set as shown Place spacer in then a seal and repeat until finishing with a seal 6 Lubricate the piston assembly with silicone lubricant Part 92360 and then rep...

Страница 32: ...ight side of the control valve when facing your softener The assembly is easy to clean start by 1 Shut the water supply to your softener OFF 2 Reduce the pressure by opening a cold treated tap 3 Using...

Страница 33: ...Check programming and reset as needed 3 UNIT USES TOO MUCH SALT A Improper salt setting B Excessive water in brine tank C Improper programming A Check salt usage and salt setting B See 7 C Check prog...

Страница 34: ...nternal control leak C Control valve jammed in brine or backwash position D Timer motor stopped or jammed teeth E Timer not operating properly A Remove piston assembly and inspect bore Remove foreign...

Страница 35: ...3 4 NPT Comes with O Ring 60090030 Elbow Drain line 1 NPT Comes with O Ring 60090028 Drain Line Hose Barb 60010227 Drain Line Red Clip 92387 Large Red Bypass Clip 60010069 Brine Line Red Clip 60010006...

Страница 36: ...sed by any force of nature is not covered in this warranty At our sole discretion we will repair or replace defective parts if our warranty department determines it to be defective under the terms of...

Отзывы: