KNOW THIS BEFORE STARTING YOUR INSTALLATION

 

Read this manual thoroughly to become familiar with  

 

the softener and its capabilities before installing or  

 operating. 

 

Failure to follow instructions could result in  

 

personal injury, property damage or death.

 

 

This manual will assist you in getting the most out of  

 

your new softener. 

 

The installation of this softener MUST be in accordance  

 

with all electrical and plumbing authorities, as well as all  

 

applicable local codes and ordinances.

 

Check with your local public works department for  

 

plumbing and sanitation codes. 

 

In the event that the codes conflict with any content in  

 

this manual – the local codes should be followed. 

 

Installation by a licensed plumber or certified water  

 

treatment professional is recommended. 

 

This softener is designed to operate on pressures of  

 

30 -125 psi. 

 

If the water pressure is higher than 125 psi, use a   

 

pressure reducing valve ahead of this softener. 

 

It is not uncommon for sediment, precipitated  

 

iron, or hardness to be present in water supplies.  

 

Precipitated minerals or sediment can cause damage to  

 

the seals and piston.

 

If precipitated minerals or sediment are present in  

 

your water supply this will be considered a harsh  

 

environment. The seals and piston would not be covered  

 

by warranty, stated or otherwise.  

 

Do NOT use water that is microbiologically unsafe  

 

without adequate disinfection before or after  

 

this system. 

 

This softener is capable of operating at temperatures  

 

between 4 °C – 43 °C or (40 °F -110 °F).  

 

Do NOT expose softener to freezing temperatures.  

 

Discharge lines exposed to freezing temperatures should  

 

be positioned with a downward slope. 

 

Do NOT expose softener to direct sunlight. 

 

Do not use this softener on hot water supply lines. 

 

Avoid pinched O-rings during installation by applying the  

 

silicone-based lubricant supplied. Part #92360. 

 

It is recommended to inspect and service the control  

 

valve on an annual basis.  

 

Cleaning and or replacement of piston, seals,  

 

and or spacers may be necessary depending on    

 

the raw water quality.  

 

Your installer can provide a maintenance kit for this  

 purpose. 

 

Rural applications should have a water analysis annually  

 

prior to system checkup or repair. 

 

Chlorine bleach and common iron control chemicals may  

 

generate toxic fumes when mixed. 

 

Always wear appropriate safety gear, such as safety  

 glasses.

 

NOTE

When dissolved iron is present, use the  

Problem Water Injector Kit. (See Start-up Instructions: Problem 

Water Injector Kit.)

 

NOTE

Check with your local public works department for applicable 

local plumbing and sanitation codes. Follow local codes if they 

differ from the standards used in this manual. Otherwise,  

carefully follow the instructions in this manual. Canature is not 

liable for any non-compliance with local requirements

NOTICE

The warranty provided gives you specific legal rights and  

otherwise limits your legal rights to the extent permitted by law. 

By installing and/or using this product, you are accepting these  

limits on your legal rights. Canature is NOT responsible for losses, 

injury, or death resulting from a failure to observe these safety 

precautions, or misuse or abuse of the equipment.

Содержание 785 Series

Страница 1: ...ully before operation 4 Avoid pinched O rings during installation by applying NSF certified lubricant to all seals provided with install kit 5 This system is not intended for treating water that is mi...

Страница 2: ......

Страница 3: ...RATE INFORMATION 8 FEED WATER PARAMETERS 8 UNPACKING INSPECTION 9 BEFORE INSTALLATION 10 PREPARATIONS 11 PLANNING YOUR INSTALLATION 14 INSTALLATION STEPS 16 UNDERSTAND THE SCREEN KEYPAD CONFIGURATION...

Страница 4: ...he warranty The warranty provided gives you specific legal rights and otherwise limits your legal rights to the extent permitted by law By installing and or using this product you are accepting these...

Страница 5: ...Records Contacts section as they will be important if you need to troubleshoot NOTE For cabinet models the model number and the system serial number are located under the salt lid FIND AND RECORD VAL...

Страница 6: ...43 C or 40 F 110 F Do NOT expose softener to freezing temperatures Discharge lines exposed to freezing temperatures should be positioned with a downward slope Do NOT expose softener to direct sunligh...

Страница 7: ...ill be 70 of capacity The unit counts down to the end of the 70 and then calculates how much of the 30 you used reserve It then adjusts the brine amount accordingly and regenerates that evening This f...

Страница 8: ...the worst case scenario where water hardness fluctuates Peak Flow Maximum flow that has gone through the softener Manual Regen Delay Generally used after servicing the valve so that it will regenerat...

Страница 9: ...m water injector kit is enclosed See Problem Water Injector Kit page for usage information UNPACKING INSPECTION WARNING RISK OF CHOKING Discard all leftover parts and packaging materials after install...

Страница 10: ...age them Softener resins will degrade in the presence of chlorine or chloramines above one 1 ppm If you have anything in excess of this amount you will experience reduced life of the resin Carbon filt...

Страница 11: ...er part 99003 separately for your own funnel Slowly add the gravel Depending on the type of system add the resin or media next Support Bed Gravel Media MANDATORY Wear a Dust Mask Airborne particles co...

Страница 12: ...ve the tape from the top of the riser tube Carefully position the valve over the riser tube inserting riser into the internal O ring Turn the valve clockwise into the threads of the tank until secure...

Страница 13: ...ide the brine tank 6 For installation of brine tank at the installation site pull the other end of the brine tube from the hole on the brine tank The completed assembly is below 3 Place the brine grid...

Страница 14: ...in and a 120 volt AC electrical outlet 6 Softeners should be located before the water heater on the supply line If closer than three 3 metres 10 feet install a check valve in accordance with local plu...

Страница 15: ...ector Detail AC 120V 10A Current Protect Socket BrineValve Connector Detail Twin Tank Softener Laundry Stack AC 120V 10A Current Protect Socket Inlet Outlet Optional Overflow Assembly 5 8 Overflow Lin...

Страница 16: ...nnections straight or elbow plumbing adaptors 3 Apply the supplied lubricant 92360 to the O rings of the fittings 4 Connect the supplied straight or elbow plumbing adaptors to the bypass with red clip...

Страница 17: ...re bypass knobs are completely open otherwise the untreated water may enter through the valve OPEN OPEN CLOSE OPEN OPEN CLOSE OPEN OPEN CLOSE SERVICE INLET OUTLET INLET OUTLET BYPASS INSTALLATION STEP...

Страница 18: ...e 13 Delayed regeneration 14 RegenerationTime time of day when backwash starts 15 Refill time 16 Valve mode 17 Valve ID UNDERSTAND THE SCREEN KEYPAD CONFIGURATION Keypad Legend the terminology used on...

Страница 19: ...er Do NOT add salt to the brine tank at this time NOTE If severe loss in water pressure is ob served when the softener unit is initially placed in service the softener tank may have been laid on its s...

Страница 20: ...m Manganese x 8 __ grains of hardness These numbers can be found on your water analysis report and the equivalent grains of hardness should be added to your total hardness number The new sum of these...

Страница 21: ...1 for three seconds 3 to unlock 2 After three 3 seconds the display will beep confirming unlock 3 Press and hold button one 1 for three seconds 3 until you hear a beep This will unlock the SETTINGS m...

Страница 22: ...or four 4 key to change WATER SOURCE value For problem water set to WELL OTHER For clean city water choose MUNICIPAL REGEN TIME 02 00 AM LOAD DEFAULT NO REGEN TIME 02 00 PM PROGRAMING COMPLETE 23 Now...

Страница 23: ...event bacteria growth from stagnant water This mode is also recommended for filters as certain types of filter media can cement or harden during long periods of non use The factory setting for Smart C...

Страница 24: ...LEM WATER INJECTOR KIT For use on upflow softeners only IMPORTANT If the water source this water softener is being applied on is not municipal water and contains up to 2 0 mg l ppm of ferrous Clear Wa...

Страница 25: ...ess button two 2 until past PROGRAMMING COMPLETE PRESS SETTINGS KEY 3 SEC TO UNLOCK 1 The display may read PRESS SETTINGS KEY Press button one 1 for three seconds 3 to unlock 2 After three 3 seconds t...

Страница 26: ...the water heater OFF and shut the heater inlet water valve OFF 2 Drain hot water tank completely OPEN the InletWaterValve allowing the heater tank to be refilled with iron free water Continue flushin...

Страница 27: ...requency Maintenance materials Please see Common Spare Parts CARE OF YOUR SOFTENER To retain the attractive appearance of your new water softener occasionally clean it with a mild soap solution Do NOT...

Страница 28: ...tions happen or the unit fails to regenerate for any other reason correct the problem first then regenerate the unit manually Regenerate two times in a row to restore the reserve capacity and bring th...

Страница 29: ...of the holder and drill 1 Measure 2 inches from the top of the tank beside the oblong molding 3 Install the holder 5 Take off the small hole cover on the BrineWell lid 4 Hang the ResCare bottle on the...

Страница 30: ...oz ResCare SERVICING YOUR CONTROL VALVE BEFORE SERVICING YOU WILL NEED TO 1 Shut the water supply to the softener OFF put the softener into the BYPASS position 2 Relieve water pressure in the softene...

Страница 31: ...l and repeat until finishing with a seal Important use the specialized end spacer and note it s placement 6 Lubricate the piston assembly with silicone lubricant Part 92360 and then replace the Piston...

Страница 32: ...salt and silt will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing...

Страница 33: ...will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing your softener...

Страница 34: ...tion Unplug power for 30 seconds then reconnect If the alarm continues contact your authorized installer UNIT REGENERATES BUT DOES NOT USE SALT Drain line flow control is plugged Clean or replace inje...

Страница 35: ...be running at the drain 1 Replace the motor and transformer if unable to determine the output of the transformer separately 2 Contact your authorized installer for parts and or assistance COMMON SPAR...

Страница 36: ...d by any force of nature is not covered in this warranty At our sole discretion we will repair or replace defective parts if our warranty department determines it to be defective under the terms of th...

Отзывы: