8
FLOW RATE INFORMATION
FEED WATER PARAMETERS
At the stated service flow rates, the pressure drop through these devices will not exceed 15 psig.
Peak flow rates are intended for intermittent use only (10 minutes or less) and are for residential applications only. Do not use peak flow rate for
commercial applications or for a continuous rate when treated water supplies are geothermal heat pump, swimming pool, etc.
For satisfactory operation, the pumping rate of the well system must equal or exceed indicated backwash flow rate.
NOTE
HTO, HNU models
See
Start-Up Instructions - Problem Water Injector
Kit
if you have iron in your water and are installing an
upflow water conditioner.
HEDP
Hardness
= > 75 gpg
Maximum Iron
= Max 2 ppm ferrous
Maximum Manganese
= 0.75 ppm
Maximum Hydrogen Sulfide
= 0.0 ppm
Maximum TDS
= 2000 ppm
pH
= 6.5 to 7.5
HTO/HTOK
Maximum Hardness
= 75 gpg
Maximum Iron
= Max 2 ppm ferrous
Maximum Manganese
= 0.75 ppm
Maximum Hydrogen Sulfide
= 0.0 ppm
Maximum TDS
= 2000 ppm
pH
= 7.0 to 8.0
SIMTAN/HIMTLC
Maximum Hardness
= 75 gpg
Maximum Iron
= Max 10.0 ppm Total with of pH < 7.2
Maximum Manganese
= 0.75 ppm
Maximum Hydrogen Sulfide
= 0.0 ppm
Maximum TDS
= 1500 ppm
pH
= 6.5 to 7.2
Maximum Tannin
= 3.0 ppm
Maximum Sulphates
= < 500 ppm
SIMNU
Maximum Hardness
= 75 gpg
Maximum Iron
= Max 10.0 ppm Total with of pH < 7.2
Maximum Manganese
= 0.75 ppm
Maximum Hydrogen Sulfide
= 0.0 ppm
Maximum TDS
= 2000 ppm
pH
= 6.5 to 7.0
HNU
Maximum Hardness
= 75 gpg
Maximum Iron
= 0.0 ppm
Maximum Manganese
= 0.0 ppm
Maximum Hydrogen Sulfide
= 0.0 ppm
Maximum TDS
= > 200 ppm
pH
= 6.5 to 7.0