MLMux4 User's Guide   

 

2.6 MLWebHardware Configuration

 

To configure MLWebHardware to use the MLMux4 navigate to the Configure Multiplexer form of the device 
containing the MLMux4 to be configured and 

Add

 a new Multiplexer.  

See the 

MLWebHardware Users Guide

 for details on access MLWebHardware and configuring new device 

programs. 

 

1.  Select 

CAN MLMux4

 as the Mux Type on the

 Multiplexer

 form.  

2.  Select either 

4 (4wires) 

or 

8 (2 wires)

 from the Channels dropdown. This should match the switch settings of the 

MLMux4.  

3.  Be sure to match the 

Enable

 and 

Clock

 settings of the form with the physical wiring.  

4. 

Save

 the new Multiplexer.  

Channels are then configured by pressing the 

Configure Channels

 button. See the 

MLWebHardware Users 

Guide

 or the MLRemote Users guide for details on channel configuration. 

 

 

 

Содержание MLMux4

Страница 1: ...MLMux4 User s Guide Initial Release February 2022...

Страница 2: ...o warranty as to the suitability of this information and or products for any given application or use Warranty Policy Canary Systems warrants products manufactured by Canary Systems excepting software...

Страница 3: ...ppliers specifically disclaim any express or implied warranty of fitness for High Risk Activities Documentation and Release Notes To obtain the most recent version of all Canary Systems technical docu...

Страница 4: ...ur technical documentation and user s guides at https canarysystems com support users guides The following documents contain information that may be useful throughout the course of this manual MLWebHa...

Страница 5: ...6 1 2 Specifications 6 Section 2 Operation and Installation 7 2 1 Operation Details 7 2 2 Enclosure Installation 8 2 3 Input Protection 9 2 4 Controller Connections 10 2 5 Instrument Connection 11 2...

Страница 6: ...e of at least 40 C to 85 C The use of low contact resistance relays means almost universal instrument support a degree of lightning protection on the control lines and virtually infinite channel isola...

Страница 7: ...l In the case of a single control line only the Clock terminal is used The Enable signal is not required and the Enable terminal must remain unconnected The device control differs only in the increase...

Страница 8: ...er s Guide 2 2 Enclosure Installation The MLMux4 can be mounted to any surface with 4 6 32 mounting screws Hint The MLMux4 comes pre installed when ordered with the MLRemote The placement of the mount...

Страница 9: ...ck inputs can be connected to 12 volts directly without damaging the MLMux4 The connections to the MLRemote module or datalogger should be disconnected and insulated from contacting other electrical c...

Страница 10: ...cription H1 H1 High side of CH1 L1 L1 Low side of CH1 H2 Not Used High side of CH2 L2 Not Used Low side of CH2 S S Cable Shield PWR PWR 12V Power GND GND Ground EN EN Enable CLK CLK Clock The figure b...

Страница 11: ...ecting Vibrating Wire Instruments to the MLMux4 Each VW sensor typically has four wires and a shield The wires are inserted into the terminal on the MLMux4 Record the serial number of the sensor so th...

Страница 12: ...ss MLWebHardware and configuring new device programs 1 Select CAN MLMux4 as the Mux Type on the Multiplexer form 2 Select either 4 4wires or 8 2 wires from the Channels dropdown This should match the...

Страница 13: ...s Guide 13 Section 3 Troubleshooting 3 1 Troubleshooting Flowchart If you cannot obtain readings using the MLMux4 or the readings are unstable then see the troubleshooting flowchart below for help in...

Отзывы: