background image

Sep-07

UNPACKING

Once the packaging has been removed inspect the unit carefully.  Check for loose, missing, or damaged parts.  Rotate 
the wheel by hand to ensure the wheel spins freely.  Tighten all set screws. 

INSTALLATION

1.  Complete ductwork termination to the top of the curb per Figure 2.

F

igure

 

2:

 Installat

i

on 

Me

thod

Not

e:

 Ch

e

ck th

e

 

i

nt

eri

o

r

 of th

e

 blow

er

 ho

u

s

i

n

g

.  It sho

u

ld b

e

 cl

e

an and f

ree

 of d

e

b

ri

s.

2.  Hoist the exhauster onto the curb.  This may be accomplished by attaching hooks into the eye hooks provided.

Do not lift unit by placing a sling around the shaft. 

3.  Position exhauster onto curb and secure using hinge kit provided in the parts bag.  Note: Bottom bolt on hinge kit 

should be tightened during operation and moved to the center hole when opened. 

4.  Rotate the blower wheel by hand.  It should not rub against the housing inlet.  If rubbing occurs, loosen the set 

screws on the wheel hub and shift the wheel to obtain clearance.  Retighten all set screws. 

5.  Insert the four 3/8” bolts through the slotted motor platform to match the bolting configuration of the motor to be 

installed.  Note: Loosely mount the motor to the sliding motor platform using the four 3/8” hex bolts, nuts and flat 
washers provided. 

6.  Mount the blower sheave on the blower shaft and tighten its set screw securely on the key of the shaft.  (See 

Table 1 for Drive Data) 

7.  Mount the motor sheave on the motor shaft.  Leave some clearance between the pulley and the motor end bell.

Tighten the set screws on the key of the motor shaft. 

8.  With the motor positioned as close as possible to the blower shaft, install the V belt within the sheave grooves.

Adjust the sheave on the blower shaft to ensure proper pulley alignment (See Figure 3) and secure in place.  A 
straight edge across the face of the driven pulley should be parallel to the belt once proper alignment has been 
achieved. (see Figure 3) 

Содержание HRE-13

Страница 1: ...onstructed from continuously welded 16 gauge steel complete with tilted access and 2 drain for cleaning Complete access for motor and drive installations and servicing may be completed by removal of the drive compartment cover Pre lubricated ball bearings curb cap motor adjustment hardware and a dynamically balanced wheel are standard equipment Operating temperature range is 30 to 400 deg F For Un...

Страница 2: ... inlet If rubbing occurs loosen the set screws on the wheel hub and shift the wheel to obtain clearance Retighten all set screws 5 Insert the four 3 8 bolts through the slotted motor platform to match the bolting configuration of the motor to be installed Note Loosely mount the motor to the sliding motor platform using the four 3 8 hex bolts nuts and flat washers provided 6 Mount the blower sheave...

Страница 3: ... 725 950 950 1100 1100 1300 1300 1600 1600 1950 1VL44 BK80H BK70H BK60H BK50H BK40H B35 B33 B31 B29 B28 B34 B33 B31 B29 B28 B33 B31 B29 B27 B26 1108 1355 1355 1538 1539 1778 1778 2108 2108 2587 1VP71 BK90H BK80H BK70H BK60H BK50H B39 B40 B38 B36 B34 B32 B38 B39 B37 B36 B33 B32 B37 B38 B36 B34 B32 B30 HRE SIZE 20 24 SHAFT SIZE 1 3 16 1 7 16 MAX RPM 1950 1600 RPM MOTOR PULLEY BLOWER PULLEY 56 CNTR D...

Страница 4: ... greasing may cause damage to the bearing Avoid rupturing the bearing seal 6 Inspect V belts for wear and proper tension If it is necessary to replace one belt on a multiple belt drive replace all the belts with a matched set Do not use belt dressing 7 Clean the blower wheel periodically Material build up on the blades can cause wheel imbalance which may result in wheel or bearing failure 8 To rei...

Отзывы: