background image

Oct-07

Delhi Industries Inc.  523 James Street, Delhi, Ontario N4B 2Z3 
Tel. (519) 582-2440     Fax. (519) 582-0581

www.delhi-industries.com

ELECTRICAL

WARNIN

G:

 Ensure power supply 

i

s d

i

sconnected and locked out pr

i

or to mak

i

n

g

 electr

i

cal connect

i

ons.

Before connecting the motor to the electrical supply, check the electrical characteristics and wiring instructions as 
indicated on the motor nameplate or as shown below.  Complete electrical connections as indicated. 

WARNIN

G:

 A 

g

round w

i

re must be connected from the motor hous

i

n

g

 to a su

i

table electr

i

cal 

g

round.

OPERATION

1.  After electrical connections are completed, remove belts, energize the motor momentarily to ensure proper 

motor rotation.  Re-install the belts. 

2.  With the air systems in full operation and all ducts and access panels attached, measure current input to the 

motor and ensure that it is less than the rated full load motor amperage. 

3.  Proper adjustment to the belt tension is critical for quiet efficient operation. 

MAINTENANCE

Ensure power supply 

i

s d

i

sconnected and locked out pr

i

or to perform

i

n

g

 ma

i

ntenance

1.  Inspect and tighten the wheel hub bolts after the first 50 to 100 hours of operation and periodically thereafter. 

2.  Follow the motor manufacturer’s instructions for motor lubrication.  Remove any excess lubrication. 

3. Drives: 

A

 – Check belt tension and alignment, replace cracked or worn belts.  If it is necessary to replace one

belt on a multiple belt drive, replace all the belts with a matched set. 

B

 – Under normal conditions, no re-lubrication is the rule.  The bearing lubricant cavity is 1/3-1/2 filled as 

shipped from the factory.  Never lubricate new bearings. 

C

– Tighten set-screws on sheaves, wheel and bearing locking collars. 

4.  Clean the blower wheel periodically.  Material build up on the blades can cause wheel imbalance which, may 

result in wheel or motor bearing failure. 

5.  Generally, bearings should be lubricated at six to twelve month intervals.  Recommended lubricants are: a) 

Imperial Oil – ESSO Beacon 325, or b) Shell Oil – Alvania Grease #3.  A small amount of grease should be 
added slowly when the shaft is rotating. 

Note

:

 Over 

g

reas

i

n

g

 may cause dama

g

e to the bear

i

n

g

.  Avo

i

ruptur

i

n

g

 the bear

i

n

g

 seal.

6.  To reinstall replacement ball bearings press the locking collar against the inner ring of the bearing and turn in the 

direction of the shaft rotation until engaged.  Insert a drift pin into the pin hole and tap lightly to set.  Tighten set-
screw on locking collar firmly. 

7.  Should further service to the blower be necessary, refer to the exploded view illustration (see Figure 4). 

Содержание DPL-12

Страница 1: ...jury and or property damage Retain instructions for future reference Fig 1 MODEL MAX H P SHAFT DIA WEIGHT DPL 12 7 1 2 1 51 DPL 13 7 1 2 1 57 DPL 15 7 1 2 1 68 DPL 16 10 1 3 16 80 DPL DPL AF 18 7 1 2 10 1 3 16 91 81 DPL DPL AF 20 10 15 1 3 16 104 96 DPL DPL AF 22 10 15 1 7 16 148 139 DPL DPL AF 24 15 20 1 7 16 185 162 DPL DPL AF 27 15 25 1 7 16 205 185 DPL DPL AF 30 20 30 1 11 16 236 248 DPL DPL A...

Страница 2: ...d the motor end bell Tighten the set screws on the key of the motor shaft 6 When using the 10 30 HP motor platform with the slide base in its minimum position install the V belt within the sheave grooves Adjust the sheave on the blower shaft to ensure proper pulley alignment see Figure 3 and secure in place A straight edge across the face of the driven pulley should be parallel to the belt once pr...

Страница 3: ...oss 2 Influence of adjacent plenum walls ESTIMATED LOSSES DUE TO PLENUM OUTLETS Outlet losses based on the outlet configuration and duct velocity must be included in the systems external static pressure requirements Outlet losses are dependent on the direction of the outlet shape of the outlet and size of the Plenum On Plenum s with more than one discharge select the configuration that has the gre...

Страница 4: ...Oct 07 Delhi Industries Inc 523 James Street Delhi Ontario N4B 2Z3 Tel 519 582 2440 Fax 519 582 0581 www delhi industries com CORRECTION FACTORS DUE TO INFLUENCE OF ADJACENT PLENUM WALLS ...

Страница 5: ... thereafter 2 Follow the motor manufacturer s instructions for motor lubrication Remove any excess lubrication 3 Drives A Check belt tension and alignment replace cracked or worn belts If it is necessary to replace one belt on a multiple belt drive replace all the belts with a matched set B Under normal conditions no re lubrication is the rule The bearing lubricant cavity is 1 3 1 2 filled as ship...

Страница 6: ... one year against manufacturing defects in material and workmanship when operating under normal conditions Liability is limited to the replacement of defective parts Labour and transportation costs are not included 5 PARTS LIST 1 PLENUM INLET WALL 2 DETACHABLE INLET VENTURI 3 C SHAPED FRAME 4 T BAR 5 PILLOW BLOCK BEARING 6 SHAFT 7 BACKWARDLY INCLINED FLAT BLADE STEEL WHEEL OR BACKWARDLY INCLINED A...

Отзывы: