30
Coupling alignment procedures should be re-checked after 10/15 hours of
operation, during which time any “settling” of the system should have taken
place. If this is not possible, the power unit should be raised approximately
1mm on each mount after completing the alignment procedure.
5.
If the distance between the underside of Nyloc Nut ‘A’ and the top of
Locknut ‘B’ exceeds 15mm, then a 5mm Packing Piece should be inserted
between the base of the mount and top face of the beds. Nyloc Nut ‘A’
should then be adjusted to compensate.
6.
Following any height adjustment on the mountings, alignment of the
Coupling Flanges should be re-checked after tightening the Top Nut ‘C’ and
Mount to Bed Bolts securely.
NOTE……Locknut ‘B’ should NOT be loosened or adjusted at any time.