32
Calorifier Position
The Canaline Marine range has been developed to operate with approximately 3m
of piping between the engine and Calorifier, with a minimum number of bends
and restrictions in this pipework. We recommend the Calorifier Inlet and Outlet
connections be no more than 300 to 450mm either above the top of the engine or
below the bottom of the engine sump.
Provided these criteria are applied and the system is fully bled of air, then
satisfactory performance should result.
Both Feed and Return connections are situated on the engine side of the
Thermostat and water is therefore allowed to circulate around the Calorifier
Circuit at all times. It should be noted that during long periods of engine
operation, when no hot water is drawn from the Calorifier, that the hot water
temperature within could approach 80 deg C. Under these circumstances,
extreme care should be taken when using the hot water circuit.
Engine Idle Speed
The Canaline Marine engines idle speed should be set between 850 – 900 r/min,
however this can be adjusted by the installer if the engine idle speed is incorrect
without effecting the engines warranty.
To change idle speed, please adjust accordingly
Loosen nut A, and adjust idle speed with bolt B, then re-tighten nut A to lock the
idle speed, please ensure the cable is then re-adjusted accordingly
Nut A
Bolt B