![CanadianSolar CSI Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/canadiansolar/csi/csi_manual_4071093010.webp)
.16.
.17.
5.
Installation
5.
Installation
4.0~6.0
4.0
(
12AWG
)
(
12~10AWG
)
Before connecting inverter, please make sure the PV array open circuit
voltage is within the limit of the inverter.
Before connection, please make sure the polarity of the output voltage of
PV array matches the
“
DC+
”
and
“
DC-
”
symbols.
Figure 5.15 DC+ Connector
Figure 5.16 DC- Connector
Please use appropriate DC cable for PV system.
Cable type
Cross section
(
mm
²
)
Range
Industry generic PV cable
(
model:PV1
-
F
)
Recommended value
The steps to assemble the DC connectors are listed as follows:
1. Strip off the DC wire for about 7mm, Disassemble the connector cap nut. (see Figure 5.17)
3. Crimp the contact pin to the wire using a proper wire crimper. (see Figure 5.19)
2. Insert the wire into the connector cap nut and contact pin. (see Figure 5.18)
4. Insert metal connector into top of connector, and tighten nut with torque 3-4 Nm
(see figure 5.20).
5.3.2 Connect PV side of inverter
+
-
Figure 5.21 Multimeter measurement
Figure 5.22 Connect the DC
Connectors to the Inverter
5. Measure PV voltage of DC input with multimeter, verify DC input cable polar
(see figure 5.17), and ensure each string of PV voltage in range of inverter operation.
Connect DC connector with inverter until hearing a slight clicking sound indicates
connection succeed. (see figure 5.18)
Figure 5.17 Disassemble the Connector Cap nut
Figure 5.18 Insert the Wire into the
Connector Cap nut and contact pin
Figure 5.19 Crimp the contact pin to the wire
Figure 5.20 Connector with Cap nut Screwed on
Crimping plier
ON
OFF
DC1
DC2
DC3
DC4
DC5
DC6
DC7
DC8
COM1
METER
DRM
SWITCH
Caution:
If DC inputs are accidently reversely connected or inverter is faulty or not
working properly, it is NOT allowed to turn off the DC switch as it will damage
the inverter and even leads to a fire disaster.
The correct actions are:
*Use a clip-on ammeter to measure the DC string current.
*If it is above 0.5A, please wait for the solar irradiance reduces until the
current decreases to below 0.5A.
*Only after the current is below 0.5A, you are allowed to turn off the DC
switches and disconnect the PV strings.
Please note that any damages due to wrong operations are not covered in
the device warranty.