8. Maintenance

Canadian Solar Three Phase Inverter does not require any regular maintenance. However, 

cleaning the dust on heat-sink will help the inverter to dissipate the heat and increase its life 

time. The dust can be removed with a soft brush.

8.1 Anti-PID Function

Canadian Solar Three phase Inverters integrates optional Anti-PID module and it can recover 

the PID effect during night thus protect the PV system from degradation.

Figure 8.1

PID

U

V

W

V+

GND

PV+

PV-

Inverter

CAUTION: 

Do not touch the inverter's surface when it is operating. Some parts of the 
inverter may be hot and cause burns. Turn off the inverter (refer to Section 
6.2) and wait for a cool-down period before any maintenance or cleaning 
operation.

The LCD and the LED status indicator lights can be cleaned with a damp cloth if they are too 

dirty to be read. 

NOTE: 

Never use any solvents, abrasives or corrosive materials to clean the inverter.

WARNING

 

The PID function is automatic. When the DC bus voltage is lower than 260Vdc, 
the PID module will start creating 650 Vdc between PV- and ground. 
No need any control or settings

The Anti-PID module repairs the PID effect of the PV model at night. When operating, 

the inverter LCD screen displays " PID-repairing " information, and the red light is on.

The Anti-PID function is always ON when AC is applied.

If maintenance is required and turn off the AC switch can disable the Anti-PID function.  

7.5.15 I/V Curve

This function is used to scan the I/V characteristic curves of each PV strings.

Figure 7.49 I/V Curve

Set I/V Curve
I/V Curve Scan

7.5.15.1 Set I/V Curve

This setting can set the scanning voltage start point and the voltage interval.

Figure 7.50 Set I/V Curve

100V
010V

7.5.15.2 I/V Curve Scan

Press “ENT” to start the I/V curve scan.

Figure 7.51 I/V Curve Scan (1)

Scanning...01

After it is completed, the screen will display “Scan OK” and then enter the following section.

Figure 7.52 I/V Curve Scan (2)

Select String No.: 01

Figure 7.53 I/V Curve Scan (3)

9.56A
9.44A

Start_V: The start voltage of the I/V scan. (Adjustable from 100V-1400V)

Interval_V: The scanning voltage interval.(Adjustable from 001V-100V) 

In total, 60 data points can be scanned.

The max scanning range is from 100-1450V.

7. Normal operation

.57.

.56.

Содержание CSI-185K-T600GL02-U

Страница 1: ...k CA 94596 Tel 1 888 998 7739 Sales Inquiries Email sales us csisolar com Technical Inquiries Email service ca csisolar com Please adhere to the actual products in case of any discrepancies in this us...

Страница 2: ...equipment has supplied The customer is fully liable for any modifications made to the system therefore any hardware or software modification manipulation or alteration not expressly approved by the ma...

Страница 3: ...on Data 36 7 4 9 Warning Message 36 7 5 Advanced Settings Technicians Only 37 7 5 1 Selecting Standard 37 7 5 2 Grid ON OFF 39 7 5 3 Clear Energy 40 7 5 4 Reset Password 40 7 5 5 Power control 40 7 5...

Страница 4: ...n bolt M10 40 Remarks 4 5 Fastening screw hex nut and flat gasket 4 DC connector DC Switch Standard DC Inputs AC Output Hexagon bolt M6 12 3 Fastening screw 2 28 DC Coupled Port Reserved Canadian Sola...

Страница 5: ...n condensing Do not stack more than two 2 inverters high on a single pallet Do not stack more than 2 pallets high Keep the box es away from corrosive materials to avoid damage to the inverter enclosur...

Страница 6: ...inverter heat sink can reach 167 F 75 The inverter is designed to work in an ambient temperature range between 25 140 F 32 60 If multiple inverters are installed on site a minimum clearance of 27 5 in...

Страница 7: ...e sound level from the inverter can be quite high 3 2 Product handling Figure 3 3 Handles used to move the inverter shown circled in red 3 1 2 4 Air circulation Do not install in small closed rooms wh...

Страница 8: ...nverter The inverter can be mounted to the wall or metal array racking The mounting holes should be consistent with the size of the bracket or the dimensions shown in Figure 3 6 Figure 3 6 Inverter wa...

Страница 9: ...pper core cable The grounding wire should be at least half size of the hot wires To connect the grounding terminal on the heat sink please follow the steps below A B Important 3 Strip the ground cable...

Страница 10: ...t pin 4 Insert metal connector into top of connector and tighten nut with torque 2 2 3 ft lbs 3 4 2 Connect PV side of inverter Please see table 3 1 for acceptable wire size for DC connections Wire mu...

Страница 11: ...ere are high voltages present when PV modules are exposed to light causing a risk of death due to an electric shock from touching a DC conductor Only connect the DC cables from the PV module to the in...

Страница 12: ...R CONNECT MORE THAN ONE CONDUCTOR PER TERMINAL NOTE Use M10 crimp terminals to connect to the inverter AC terminals Figure 3 18 Strip AC cable NOTE S2 insulation stripping length is 2mm 3mm longer tha...

Страница 13: ...inverters Multiple inverters can be monitored through RS 485 daisy chain configuration Internet Datalogger PC monitoring PV Strings Inverter PV Strings PV Strings Inverter Inverter Figure Multiple inv...

Страница 14: ...below WARNING Failure to set the correct grid standard could result in improper operation of the inverter inverter damage or the inverter not operating at all 5 2 Changing the grid standard 5 2 1 Pro...

Страница 15: ...o ensure it is fully captured in the terminal 2 Visually check for any stray strands that may not be inserted in the terminal 3 Check to ensure the terminal screws are the correct torque 5 4 2 AC Conn...

Страница 16: ...ter s start up voltage the inverter will turn on The red DC POWER LED and LCD will be continuously lit 4 Canadian Solar inverters are powered from the DC side When the inverter detects DC power that i...

Страница 17: ...atus Waiting Power 0000W Grid Frequency F_Grid 00 00Hz Total Energy 0000000 kwh This Month 0000kwh Last Month 0000kwh Today 0000 0kwh Yesterday 0000 0kwh 10 sec 10 sec 10 sec 10 sec Status Shows insta...

Страница 18: ...e Inverter is 01 YES ENT NO ESC Set Address 01 Figure 7 4 Set Address Press the UP DOWN keys to set the address Press the ENTER key to save the settings Press the ESC key to cancel the change and retu...

Страница 19: ...Message This function is for maintaince person to get running message such as internal temperature Standard No 1 2 etc Screens can be scrolled manually by pressing the UP DOWN keys 7 4 Advanced Info...

Страница 20: ...service technicians only 01 05 01 25 E4 9D AA 06 10 C2 B5 E4 9D 55 Figure 7 14 Communication Data 7 4 6 Yearly Energy YES ENT NO ESC Select 2020 Figure 7 12 Select year for yearly energy 2020 0000000...

Страница 21: ...sation at night Enable Disable Figure 7 19 Set 24H Var Switch Press UP DOWN to select and press to Enter to save the setting Press the ESC to return to the previous menu OV G V1 700 900V OV G V1 T 0 1...

Страница 22: ...ESC key to return to the previous menu 7 5 5 Power Control Active and reactive power can be set through power setting button There are 6 item for this sub menu 1 Set Output Power 2 Set Reactive Power...

Страница 23: ...ve output power based on voltage change Note This Setting is NOT required by UL1741SA Standards 1 NULL Description Inverter is not under any working mode 3 Volt Var Default Description Inverter will c...

Страница 24: ...for maintenance personnel only wrong operation will prevent the inverter from reaching maximum power 0 6 0 6 1 0 1 0 P Pn under excited Q Pn under excited over excited over excited I II IV III 0 2 7...

Страница 25: ...108 110 Real Power Reduction Zone Full Power Production Capabilities Zone 50 100 Active Power as of Nameplate Voltage 3 Volt Var Description Inverter will change the reactive output power based on vo...

Страница 26: ...red by Rule21 Standards This function is for maintenance personnel only wrong operation will prevent the inverter from reaching maximum power 0 6 0 6 1 0 1 0 P Pn under excited Q Pn under excited over...

Страница 27: ...an set the scope 61 64Hz the default setting 62Hz Press the Enter key to select the mode or frequency Press Up Down to set Press ESC to save the settings Figure 7 40 Freq Watt characteristic f min f n...

Страница 28: ...US This function is for maintenance personnel only wrong operation will prevent the inverter from reaching maximum power 7 5 8 5 Power Priority Figure 7 43 Power Priority This setting is used to set t...

Страница 29: ...ower 7 5 12 FAN Test This section is applicable to maintenance personnel only Figure 7 47 Selecting Fan Test displays the sub menu shown below Are you sure YES ENT NO ESC Fan Test is a factory test fu...

Страница 30: ...will start creating 650 Vdc between PV and ground No need any control or settings The Anti PID module repairs the PID effect of the PV model at night When operating the inverter LCD screen displays P...

Страница 31: ...G F01 02 UN G F01 02 G IMP NO GRID OV DC01 02 03 04 OV BUS UN BUS01 02 GRID INTF01 02 OV TEM Failure description Over grid voltage Under grid voltage Over grid frequency Under grid frequency High grid...

Страница 32: ...d on the LCD and the status of the LED status indicator lights Other readings obtained from the Information submenu refer to Section 6 2 will also be helpful 5 The PV array configuration e g number of...

Страница 33: ...telligent redundant cooling 13120ft 4000m Dimensions W H D Weight 3 PE 800 Max DC input voltage Volts MPPT voltage range Volts Max input current Amps MPPT number Max input strings number Rated grid vo...

Страница 34: ...ed derate at 45 C ending at 78 output power at 60 C Temperatures above 60 C and below 25 C will derate to 0 output power Ambient Temperature Power W 185000 146160 580 850 1300 Voltage V 1500 11 Append...

Страница 35: ...ompleted Record V AC in Notes 10 Grounding cable Good Poor INSTALLATION Check inverter condition after unpacking Install inverter mounting bracket according to installation instructions in user manual...

Страница 36: ...cable to the communication port 1 Switch the grid supply main Switch AC ON rst 2 Switch the DC switch ON If the voltages of PV arrays are higher than start up voltage the inverter will turn on The re...

Страница 37: ...eted Record address in Notes 7 Machine version For maintenance and reference please record the irmware revisions if applicable Completed Record with serial numbers 8 Operating parameter Record operati...

Страница 38: ...ting tilt Output power Input DC voltage Insulation limit K PV start up voltage Grid V Max V Min Frequency Max Min Reactive compensation PF Coniguration MPPT Individual MPPT Parallel Monitoring RS485 E...

Страница 39: ...to inverter site selection and installation 3 PHASE STRING INVERTERS KTL SERIES CSIF ST 016 A 0 INSTALLER S NAME INSTALLER S SIGNATURE COMPANY DATE Inverter serial numbers 1 2 3 4 5 6 7 8 9 10 11 12 1...

Отзывы: