Fill it up!

Preparation and Filling

Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before filling to allow

as much air as possible to escape from the plumbing and the control system during the filling process.

After turning the power on at the main power panel, the top-side panel display will go through specific sequences. These

sequences are normal and display a variety of information regarding the configuration of the hot tub control.

Priming Mode - MO19*

This mode will last for 4-5 minutes or you can manually exit the priming mode after the pump(s) have primed.

Regardless of whether the priming mode ends automatically or you manually exit the priming mode, the system will

automatically starts normal heating and filtering at the end of the priming mode. During the priming mode, the heater is

disabled to allow the priming process to be completed without the possibility of energizing the heater under low-flow or

no-flow conditions. Nothing comes on automatically, but the pump can be energized by pushing the “Jets”

or “Aux” buttons.

Priming the Pump

As soon as the above display appears on the panel, push the “Jets” button once to start the Pump in low-speed and then again 

to switch to high-speed. will now be running in high-speed to facilitate priming. If the pump has not primed after 2 minutes, and 

water is not flowing from the jets in the spa, do not allow the pump to continue to run. Turn off the pump and repeat the process. 

Note: Turning the power off and back on again will initiate a new pump priming session. Sometimes momentarily turning the 

pump off and on will help it to prime. Do not do this more than 5 times. If the pump will not prime, shut off the power to the spa 

and call for service.

Important: A pump should not be allowed to run without priming for more than 2 minutes. Under NO circumstances should

a pump be allowed to run without priming beyond the end of the 4-5 minute priming mode. Doing so may cause damage to

the pump and cause the system to energize the heater and go into an overheat condition.

Exiting Priming Mode

You can manually exit Priming Mode by pressing the “Warm” or “Cool” button. Note that if you do not manually exit the

priming mode as described above, the priming mode will be automatically terminated after 4-5 minutes. Be sure that the

pump have been primed by this time. Once the system has exited Priming Mode, the top-side panel will momentarily display the 

set temperature but the display will not show the water temperature yet, as shown below.

This is because the system requires approximately 

1 minute of water flowing through the heater to 

determine the water temperature and display it.

R U N

P M P 5

P U R G

A I R

- - - -

- - - C

Ready Mode and Rest Mode 

In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this function is

known as the “primary pump.”

Primary pump is a 2-Speed Pump 1, Ready Mode (indicated by     ) will circulate water periodically, using Pump 1

Low, in order to maintain a constant water temperature, heat as needed, and refresh the temperature display. 

This is known as “polling.”

Rest Mode (indicated by     ) will only allow heating during programmed filter cycles. Since polling does not occur, the

temperature display may not show a current temperature until the primary pump has been running for a minute or two.

In Rest Mode, the spa will only heat to set temperature during programmed filter times.

Water Temperature Setting 

Содержание Vancouver UV Spa KH-10032

Страница 1: ...V A N C O U V E R Vancouver UV Spa Owners Manual 228 x 228 x 87cm 90 x 90 x 36 KH 10032 For Service Support please contact us anytime support canadianspacompany com canadianspacompany com...

Страница 2: ...Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a spa f Persons using medication sh...

Страница 3: ...air DRAIN VALVE Valve located on the outside of spa cabinet used to drain water from the spa A garden hose can be attached to the drain valve EQUIPMENT BAY Located under the spa shell covered by acces...

Страница 4: ...lled it will be necessary to have a dedicated electrical circuit supply fitted You will require up to 32 Amp type C Breaker supply dependent on the length from the service point Your spa must be prote...

Страница 5: ...d position Draining your Spa Using drain valve IMPORTANT Before draining your spa shut off the electrical breaker connected to the spa Accessing your spa controls To access the Control Pack undo the 3...

Страница 6: ...ble The spa will heat approximately 1 every 30 minutes per 1 000 litres 6 Check for leaks Although spas are fully checked at the factory shipping delivery might cause a leak Remember to pay particular...

Страница 7: ...Spa Flush Annually flush the spa to remove bio film that has attached to the interior of the spa pipes KA 10164 Spa Functions Pumps Press the Jets 1 button once to turn pump 1 on or off and to shift...

Страница 8: ...an Spa Company channel pH LOW pH HIGH pH NORMAL 7 2 7 6 Reduced ef cacy of disinfection Corrosion of metals Skin eye irritation Unpleasant odour Reduced ef cacy of disinfection Skin eye irritation For...

Страница 9: ...Cycle duration Based on usage adjust filtration cycle duration High solids content See common water problem section Settings 2 x Pumps standard Simple Options Press Menu button until you reach the mo...

Страница 10: ...pump off and on will help it to prime Do not do this more than 5 times If the pump will not prime shut off the power to the spa and call for service Important A pump should not be allowed to run with...

Страница 11: ...started at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the panel p...

Страница 12: ...e will last for 1 hour unless the mode is exited manually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this feature is a compone...

Страница 13: ...to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry MO27 There is not enough water in the heater to start it The spa...

Страница 14: ...7 days can be specified by the Manufacturer Press a Temperature button to reset a displayed reminder message Alternates with temperature or normal display Appears on a regular schedule e g every 7 da...

Страница 15: ...nce or protection is essential Canadian Spa Co warrants the cover for the period of two 2 years Defects caused by misuse or insufficient care are not covered by the warranty TERMS CONDITIONS AND LIMIT...

Отзывы: