Reminder Messages

General maintenance helps.

The display of Reminder Messages can be suppressed by 

using the PREF Menu.

Reminder Messages can be chosen individually by the 

Manufacturer. They may be disabled entirely, or there may be a 

limited number of reminders on a specific model. The 

frequency of each reminder (e.g. 7 days) can be specified by 

the Manufacturer.

Press a Temperature button to reset a displayed reminder 

message.

    

 

 

Alternates with temperature or 

normal display.

Appears on a regular schedule, e.g. every 7 days.

Check pH with a test kit and adjust pH with the appropriate 

chemicals.

 

 

 

   Alternates with temperature or 

normal display.

Appears on a regular schedule, e.g. every 7 days.

Check sanitizer level and other water chemistry with a test kit 

and adjust with the appropriate chemicals.

 

 

 

   Alternates with temperature or 

normal display.

Appears on a regular schedule, e.g. every 30 days.

Clean the filter media as instructed by the manufacturer. 

Appears on a regular schedule, e.g. every 30 days.

Residual Current Device (RCD) is an important safety device 

and must be tested on a regular basis to verify its reliability.

Every user should be trained to safely test the RCD associated 

with the Swim Spa installation. An RCD will have a TEST and 

RESET button on it that allows a user to verify proper function.

Warning:

If freezing conditions exist, a RCD should be reset 

immediately or spa damage could result. The end user should 

always trained to test and reset the RCD on a regular basis.

C H E K

  P H

C H E K

C H E M

C L N

SC30 Buss fuse 

30 Amp. 

KK-10382

Glass fuse 

10 Amp. 

KK-10376 

f3 fuse  

topside 1/8. 

KK-11107

Swim Spa Parts

3.5" Directional Jet

KK-10050

2.25" Massage Jet

KK-10041

2.25" Directional 

Jet 

KK-10040

2.25" Small Point 

Jet 

KK-10039

5" Massage Jet

KK-10053

5" Directional Jet

KK-10052

3.5" Massage Jet

KK-10051

10” Waterfall 

KK-10155

Bread Pillow

KK-010145

Pop-Up Speaker

KK-10043

Big Red LX 5 hp 

2 speed Pump

KK-10319

Air Control

KK-10184

Waterfall valve 

KK-10141

Water Diverter

KK-10191

Aromatherapy Cap

KK-10209

LED Light

KK-10213

BP600/ 2100  (M7) 

Heater 3kW

KK-10285

Audio Control

(6 Button)

KK-11320

UV + Ozone 

KK-KK-11328

Big Red LX 5 hp 

1 speed Pump

KK-10319

UV 15W lamp kit with 

sleeve 

KK-11202

Balboa CN613

Control 3 Kw heater

KK-10328

 90 x 90"/228 x 228 Brown Cover

(2 Part) 

KC-10259

Содержание St Lawrence 16' Swim Spa KS-10006

Страница 1: ... W R E N C E 2 0 S W I M S PA St Lawrence 20 Swim Spa Owners Manual 594 x 228 x 137 cm 234 x 90 x 54 KS 10006 For Service Support please contact us anytime support canadianspacompany com canadianspacompany com ...

Страница 2: ...onths to make sure that the unit is operating properly 14 CAUTION Do not operate audio video controls while inside the spa 15 Installation of the spa for other than a residential dwelling will result in voiding the manufacturer s warranty 16 Do not bring any object into the spa that could damage the spa shell 17 Never insert any object into any opening 18 WARNING Do not sit on the spa cover or pla...

Страница 3: ...body oils dead skin cells and hair DRAIN VALVE Valve located on the outside of spa cabinet used to drain water from the spa A garden hose can be attached to the drain valve EQUIPMENT BAY Located under the spa shell covered by access panels that houses the spa controller and equipment SLICE VALVE Two position open or closed sliding valve used to cut off water flow which allows for service to be per...

Страница 4: ...en please ask before ground construction and the delivery of your spa Your spa must be sited on a solid flat level base which is the same size or larger than the spa The base can be either a 10 15cm concrete slab or suitably strengthened timber decking or existing patio area assuming it has suitable foundations of hardcore Whatever base area is chosen it must be of suitable load bearing capacity P...

Страница 5: ...s To access the Control Pack undo the 4 screws on both panel strips Installation Electrical power requirements Power connections Single Phase A is the normal wiring configuration for most household electrical installations 3 wires live neutral and earth If however you have insufficient Amps you will need to use other connection see below 2 Single Phase connection B is used in circumstances where t...

Страница 6: ...e The last number in the sequence is the incoming power meter which can be used to verify that the spa is wired correctly 2 The spa begins an automatic priming routine which will last 6 minutes Pr is on the LED display 3 The priming routine will automatically run each spa pump to prime When the Pr is displayed press any PUMP button to prime that pump or wait for the priming routine to turn on the ...

Страница 7: ...and it will tell you what to add and how much KA 10052 Spa Flush Annually flush the spa to remove bio film that has attached to the interior of the spa pipes KA 10164 2 Pump Control System TP600 Initial Start up When your spa is first activated the display will do a count sequence of M100 L232 V52 1 3 afterwards a message will display RUN PUMPS PURGE AIR on Priming Mode TEMP DOWN Decrease Temperat...

Страница 8: ...ncing an air lock This normal occurrence can be easily corrected by loosening the plumbing union on the suction side of the Jet or Pump until water flows into the pump and all air is expelled PRESS BUTTONS SLOWLY FOR FIRST RUN WHEN STARTING UP ONCE PR EXITS SET TEMPERATURE ON SPA Airlock warning messages If you receive any of these error messages on your spa you could have an airlock FLO How to re...

Страница 9: ...nt See common water problem section Settings 2 x Pumps standard Simple Options Press Menu Temp Up then Light button until you reach the mode you require TEMP Temp Up button until arrow is either pointing up or down Arrow up will maintain heat Arrow down will drop the temp by 10 degrees Menu Temp Up then Light to select MODE Temp Up button press until either Ready or Rest is displayed Ready maintai...

Страница 10: ...mentarily turning the pump off and on will help it to prime Do not do this more than 5 times If the pump will not prime shut off the power to the spa and call for service Important A pump should not be allowed to run without priming for more than 2 minutes Under NO circumstances should a pump be allowed to run without priming beyond the end of the 4 5 minute priming mode Doing so may cause damage ...

Страница 11: ...et but since the spa started at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the panel prevents the controller from being used but all automatic functions are still active Locking the Temperature allows Jets and other features to be used but the Set Temperature and ot...

Страница 12: ... the filter Hold Mode will last for 1 hour unless the mode is exited manually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this feature is a component of Hold Mode Drain Mode will time out with Hold Mode Sub Menu Detail User Preferences 05 15 09 Preferences F C Temp Display Change the temperature between Fahrenheit and Celsius...

Страница 13: ... water in the heater to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry MO27 There is not enough water in the heater to start it The spa is shut down After the problem has been resolved you must press any button to reset and restart heater start up See Flow Related Checks RUN PMP5 PURG AIR C TOO COLD WATR TOO HOT CH...

Страница 14: ... Residual Current Device RCD is an important safety device and must be tested on a regular basis to verify its reliability Every user should be trained to safely test the RCD associated with the Swim Spa installation An RCD will have a TEST and RESET button on it that allows a user to verify proper function Warning If freezing conditions exist a RCD should be reset immediately or spa damage could ...

Страница 15: ...ar maintenance or protection is essential Canadian Spa Co warrants the cover for the period of two 2 years Defects caused by misuse or insufficient care are not covered by the warranty TERMS CONDITIONS AND LIMITATIONS Any defect or damage caused by installation alteration or repair by anyone who is not an employee of Canadian Spa Co or authorised service technician is not covered by the Warranty T...

Отзывы: