Canadian Spa Rio Grande Скачать руководство пользователя страница 7

13

Cleaning / Replacing Filter Cartridge

WARNING: RISK OF ELECTRIC SHOCK. Unplug the PCU 
before beginning spa maintenance.

NOTE:

 A dirty filter cartridge may contaminate the spa water 

and cause damage to the heating function.

1. Carefully thread the three plastic caps onto the inlet/outlet ports on inner spa wall 

  (ensure the rubber gaskets are in place within the plastic caps).

2. Remove filter housing lid, then remove the filter cartridge.

3. Rinse off filter cartridge with water and reuse if possible. Replace filter 

  if the cartridge remains dirty after rinsing or is badly discoloured.

4. Put the cleaned filter back into the cartridge housing and close the lid by  

 

 

  turning it clockwise.

5. Remove caps from inlet/outlet ports on inner spa wall and allow water to  

 

 

  flow into the PCU. Tub is now ready for use. 

Part 6 

WATER MAINTENANCE

The filter cartridge should be cleaned weekly and replaced on a monthly basis, or depending on 

use. A reminder will appear to check the filter after two weeks (‘CHG FIL’). Hold down ‘HEAT’ for 5 

seconds to clear the message. Change water once a month or depending on use and use 

appropriate spa chemicals. Please pay attention to the chemicals used and dosage. Spa damage 

resulting from misuse of chemicals is not covered by the warranty. To ensure your warranty remains 

intact we recommend using Canadian Spa Company chemicals.

Water Balance:

 We recommend you maintain your water balance: PH value: 7.2 - 7.6;  Free 

Chlorine: 2ppm - 3ppm; Alkalinity: 120-150ppm. Use a test kit to test your spa water before each 

use of the spa, or at least once per week. 

Water Sanitation:

 We suggest using chlorine or bromine granules to disinfect the spa’s water.   

NOTE: 

Chlorine/Bromine tablets are not recommended. 

Cleaning the Spa:

 Clean the spa with mild soap and water, then rinse. Leave it outside (away from 

direct sunlight) to dry.

(1.)

(2.)

(3.)

MAINTENANCE / TROUBLESHOOTING :

PROBLEM

Cloudy water

Odour

Eye skin/irritation

POSSIBLE CAUSE

High pH (test to verify)

Poor filtration

High dissolved solids

High level of organic contaminants

Low pH and/or alkalinity

Combined Chlorine due to organic 

contamination

SOLUTION

Add pH down

Clean filter w/Filter Free

Empty spa and re-fill

Increase the amount of  Chlorine

Add Alkalinity Booster

Increase the amount of Chlorine 

Granules

  

  

Part 7 

DRAIN & STORE 

Drain System

 

Locate and remove the external threaded Drain Cap. Attach Drain Hose to Drain Outlet. 

Locate and remove the stopper on the spa floor to allow water to drain. 

Dry the Spa and Portable Control Unit 

After a GFCI test, press ‘JETS’ to blow out the water inside the jet holes. Turn PCU off and 

disconnect all connectors from connection ports on the PCU. Turn PCU back on and run 

blower for 30 seconds to allow excess water to clear from blower port. Unplug GFCI and 

hold PCU at an angle, allowing water to drain from connection ports. Once water flow 

stops, remove Filter Housing Lid with filter and hold PCU upside down. Give the PCU a 

slight shake, allowing all excess water to be removed. Close Filter Housing Lid when 

complete.

NOTE:

 PCU must be stored upright. Leaving PCU at an angle or upside down may result in 

damage. 

Storage

Use a towel to wipe off the spa and dry for 24 hours. Unscrew the Air Valve on the lid.  

Once the lid has been deflated and the Foam Panels have been disassembled, gently fold 

the lid for storage. It is recommended that you store the spa in its original package in a 

warm dry place. 

Part 8 

AROMATHERAPY

To use aromatherapy, simply unscrew cap on Aromatherapy Port and insert canister of 

scented Aromatherapy Beads. Replace Cap on Aromatherapy Port. The aromatherapy 

scents will activate once the ‘JETS’ button has been pressed.

12

Содержание Rio Grande

Страница 1: ... w w c a n a d i a n S p a c o m p a n y c o m c a n a d i a n s p a c o m p a n y c o m P O R T A B L E F O A M W A L L S P A S Rio Grande Swift Current 110 115V 60Hz 15A Read this manual before operation ...

Страница 2: ...ician before using a spa c Persons using medication should consult a physician before using a spa since some medication may induce drowsiness while other medication may affect heart rate blood pressure and circulation d Pregnant or possibly pregnant women should consult a doctor before using spa CAUTION Wet areas around the spa can be slippery always enter and exit the spa slowly and cautiously CA...

Страница 3: ...e without limitation damage of the spa liner caused by leaving the spa uncovered while the spa is empty of water or not in use Damage to the spa surface caused by contact with unapproved cleaners or solvents Damage caused by unapproved sanitizers such as calcium hypochlorite tri chlor type chlorine or any sanitizing chemical that may remain undissolved on the spa vinyl surface Do not return the pr...

Страница 4: ... display will show the current water temperature automatically Temperature Adjustment Buttons Raise or lower set temperature Pressing one of the temperature adjustment buttons will cause the LED display to flash While it is flashing you can set the desired temperature The value will increase or decrease by 1 F 1 C with each press Temperature Adjustment Ranges 86 F 104 F 30 C 39 C NOTE Due to the s...

Страница 5: ...y cause ballooning in the inflatable lid Clean surface Level ground Fill the tub up to the water lines located on the interior sides of the spa to ensure the spa is level 3 Spa Assembly 1 Take the Thermal Ground Sheet and position it where the footprint of the spa will be Take the Bottom Liner and position it on top of the ground cloth 2 Position Foam Panel 1 aligning it with the corresponding hol...

Страница 6: ...Install the Filter Cartridge Open the Filter Housing lid Put the new filter cartridge into the cartridge chamber Replace Filter Housing Cap and seal by screwing Cap Fitting on NOTE Ensure orange o ring is placed correctly inside housing 6 Pre Fill Check Ensure that the drain outlet is extended for future draining access Check the stopper on the bottom of the spa and the Drain Cap ensure both are c...

Страница 7: ...the Spa Clean the spa with mild soap and water then rinse Leave it outside away from direct sunlight to dry 1 2 3 MAINTENANCE TROUBLESHOOTING PROBLEM Cloudy water Odour Eye skin irritation POSSIBLE CAUSE High pH test to verify Poor filtration High dissolved solids High level of organic contaminants Low pH and or alkalinity Combined Chlorine due to organic contamination SOLUTION Add pH down Clean f...

Страница 8: ...art 9 PORTABLE CONTROL UNIT MESSAGES CHECK 1 Water Level Ensure water level meets fill lines on both interior sides of the spa Check if this resolves the PCU s malfunctioning CHECK 2 Inside Connection Caps Make sure the plastic Inlet Outlet caps have been removed before turning on the PCU CHECK 3 Bleed Air out of Portable Control Unit If PCU makes a grinding noise no water is going to the pump Tur...

Страница 9: ... Bonus 3 x 15 ft slip replacement microban filters for Canadian Spa Co portable spas This filter 4 pack should be changed every 1 2 months depending on usage Portable Chemical Kit This chemical kit is an excellent addition to any spa and provides users with all of the essential spa chemicals needed to keep a spa balanced The following chemicals are included in the kit Chlorinated Granules 800g Alk...

Страница 10: ... 86 21 58942200 F 86 21 58940305 www canadianspacompany com Disclaimer Canadian Spa Co or any of its authorized service technicians shall not be held liable for injury inconvenience loss of use chemical or water damage transportation costs contingent liabilities or any other incidental or consequential costs expenses or damage as result of any deficiency or alleged deficiency of the spa In no even...

Отзывы: