9
NOTE:
• The massage system will stop automatically after 30 minutes of operation. You can
re-activate the jet function by pressing ‘JETS’.
NOTE:
Heater will automatically turn on when jets turn off.
• Heating and jet function cannot be activated at same time. When heating system
is working, pressing ‘JETS’ will change heating mode into jet mode: heating
and filtering are shut down, jet system is activated. When jets are turned off, heating and
filtering automatically resumes.
NOTE:
Keeping jets on for a long period of time may cause spa water to lose heat.
• Pressing ‘HEAT’ activates the heating and filtering system at the same time.
The ‘HEAT’ button will display a solid red light as spa water heats up. Once desired
temperature is reached, the heater will go into standby mode, which will be indicated
by a flashing red light.
NOTE:
Heating will not resume until spa water drops 4-5 degrees below set
temperature for maximum efficiency. You can also manually restart the heater by
pressing ‘HEAT’ when heater is turned off.
• This spa is equipped with automatic moisture protection which will activate the blower
of the PCU once a day for up to 90 seconds. This helps to prevent condensation build up
and increase the lifespan of the PCU.
Part 4
INSTALLATION
1. Site Selection
IMPORTANT:
Before you position, construct, and fill with water
follow these instructions:
1. Place in an area more than 8.2 sq ft (2.5 sq mtrs.)
2. Place spa on a surface that supports more than
661lb/ft2 (300 kg/2).
3. The spa must be on a clean level ground. If placed on
uneven ground (grass) the weight of the spa water may
cause the spa to become distorted; this is not covered by
the manufacturer’s warranty.
NOTE:
Uneven exposure to the sun may cause ballooning
in the inflatable lid.
Clean surface
Level ground
Fill the tub up to the water
lines located on the interior
sides of the spa to ensure
the spa is level.
3. Spa Assembly
1) Take the Thermal Ground Sheet and
position it where the footprint of the
spa will be. Take the Bottom Liner
and position it on top of the ground cloth.
2) Position Foam Panel 1, aligning it with the
corresponding holes in the vinyl liner.
3) Add Foam Panel 2. Slide a foam
cap on top of Foam Panel 1 and 2.
Repeat with Foam Panel 3.
4) Place remaining Blank Foam Panels next to Foam Panel 3,
continuing to add a foam cap on the top between all Foam
Panels. Ensure the 3 holes in Foam Panel 1 are still aligned
with the holes in the Bottom Liner.
2. Test
GFCI
& Inflate Lid
a) Perform
GFCI
Test
WARNING: RISK OF ELECTRIC SHOCK. The GFCI plug must be
tested before each use. Do not use if GFCI test fails.
1. Insert the plug into the power outlet.
2. Press the “RESET“ button, the indicator light will illuminate.
3. Press the “TEST” button, the indicator light turns off.
4. Press the “RESET” button, the indicator light will illuminate; the PCU is ready to use.
b) Inflate the Lid
Connect the Inflation Ho
se to the Jet Port on the P
CU and connect the other end to the
Inflation Port on the lid. Press ‘JETS’ to inflate the lid. Once inflated close the Valve Cap on
the lid and press the ‘TEST’ button on the GFCI to turn PCU off.
NOTE:
When inflating, only the top cap on the Check Valve needs to be opened, when
deflating lid, the entire valve should be unscrewed.
NOTE:
The PCU must be disconnected from the power source after completing this step.
The pump will automatically start after 20min of the spa being plugged in. Failure to power
off the unit may result in a faulty ‘E6’ Error in addition to a noise from the filter running while
the PCU is dry. If this occurs, power off the PCU. When PCU is powered back on, all errors
should be cleared.
8