background image

4

•  IMPORTANT:

 All electrical installation work must be performed by a qualified electrician and must conform 

to local codes

• 

Check to see if the proper sized GFCI is installed. 

• 

Be sure the GFCI is rated for more amperage than the system will draw. 

• 

For a 240V system, the GFCI must include a load neutral out. 

•  NOTE: If the white load neutral wire is routed from the GFCI neutral bar directly to TB1 in the system box, 

then the GFCI will trip when a 120V device is activated. This is the most common reason if your hot tub is 
tripping immediately. 

• 

If the wiring is correct and the GFCI will not reset, then unplug the heater and try to reset the GFCI. 

• 

If the GFCI trips again, then unplug the pump and reset the GFCI. If the GFCI continues to trip, then do the same procedure 

for the ozone generator. 

• 

If the GFCI stops tripping after you unplugged one of the spa’s components, turn off the power to the spa then plug in 
each component except the one that tripped the GFCI. 

• 

Power up the system. If the GFCI no longer trips, then you have correctly identified the problem. 

•  Repair or replace the component as instructed by the spa manufacturer. 
• 

If everything looks to be in perfect working order, then the GFCI may be defective.

Do 

NOT

 proceed with installing your hot tub in freezing temperatures! In colder temperatures please make sure 

to place a space heater inside the cabinet immediately after delivery for 24 to 48 hours before installation to 
prevent startup issues. 

A licensed electrician can install the wiring by drilling a hole into any panel and terminating the connection at 
the control pack.

All hot tubs must be placed on a proper base that is reinforced for the weight of the hot tub, water and people 

who may be within the hot tub at any given time. This base must be flat and come in contact with the entire 
base of the spa. We recommend a base that can support at least 150 pounds per square foot such as a 4-6 

inches poured concrete pad.

WINTER INSTALL

LICENSED ELECTRICIAN

PROPER SPA BASE

INSTALLATION

GFCI TROUBLESHOOTING (240V ONLY)

IF CORRECT WIRING IS VERIFIED

Keep in mind that the majority of 240V GFCI tripping problems can attribute to incorrect wiring. 

GFCI troubleshooting usually finds the problem

REFER TO DIAGRAM ON NEXT PAGE

WARNING: THE OWNER SHOULD TEST AND RESET THE 

GFCI ON A REGULAR BASIS TO VERIFY ITS FUNCTION

Lay your cover onto your hot tub then line up locking straps and secure with mounting hardware. Use the lock 
and key clasps to secure your cover in place. Always lock your cover when the hot tub is unattended.  

Do 

NOT 

walk or sit on the spa cover.

ATTACH SPA COVER

FOR MORE HELP GUIDES VISIT US AT:

support.canadianspacompany.com

1-877-909-7727

Содержание MUSKOKA SPA

Страница 1: ...l 60Hz Electrical 120V 15A Weight 600 lbs Dry 2600 lbs Filled Water Capacity 900 L Jet Count 14 Seat Count 5 Size 74 x 74 x 29 Pump s 1 x 2 Speed 1 5 HP Heater s 1 x 1 kW Filter s 1 x 50sq ft Glacier Antimicrobial Filter KA 10082 ...

Страница 2: ...components for example cable additional speakers headphones additional audio video components etc to system 11 CAUTION Risk of Electrical Shock Do not service this product yourself as opening or removing audio covers may expose you to dangerous voltage or other risk of injury Refer all servicing to qualified service personnel 12 CAUTION Risk of Electrical Shock When the power supply connections or...

Страница 3: ...and new spa Add Chemicals Wait for Water to Heat Enjoy Power On CA 1 877 909 7727 US 1 844 879 7727 CANADIAN SPA CO Insert Filters Fill Hot Tub Register Warranty Electrical SPA CHEMICAL S TA R T U P G U I D E canadianspacompany com Once your hot tub is filled install your new Glacier Antimicrobial Filters Remove the lid and fill the hot tub with water through the filter housing QUICKSTART GUIDE FOR M...

Страница 4: ...lling your hot tub in freezing temperatures In colder temperatures please make sure to place a space heater inside the cabinet immediately after delivery for 24 to 48 hours before installation to prevent startup issues A licensed electrician can install the wiring by drilling a hole into any panel and terminating the connection at the control pack All hot tubs must be placed on a proper base that ...

Страница 5: ...240V GFCI Electrical Installation Neutral Terminal Hot Terminal Hot Terminal Ground Terminal 1 2 3 4 Please refer to wiring diagram inside of spa pack cover for correct terminal installation Control Pack ...

Страница 6: ...6 FEATURE FUNCTIONS 1 2 Suction Intake Air Control Filter Housing 3 4 Controls topside Tem p Do wn JET S 1 Co ntrol Centre Tem p UP JET S 2 ww w c ana dian spa com pan y co m 1 4 2 3 ...

Страница 7: ...cific muscles for a precise massage where the massage style jet offers a circular and gentle massage All jets are interchangeable and adjustable Swap them around and turn them off on to customize your spa to your satisfaction Directional Massage FOR MORE HELP GUIDES VISIT US AT support canadianspacompany com 1 877 909 7727 FILTER HOUSING TOPSIDE CONTROLS This is where you will fill your hot tub wi...

Страница 8: ...ss Light button again to turn them off Turn On Pump Press the Jets button to turn the pump on low speed Press the button again for high speed To set the hour continue to hold down the Light button until the hour is flashing then use the arrow keys to adjust the number Press the Light button again for the minutes and repeat Press Light once more to complete SET TIME SET TEMP UNIT OF MEASURE The wat...

Страница 9: ...e water Remove spa cover and allow the water to cool down then shut the power off and power your spa up again to reset the system Temperature inside the spa skirt is too high causing the internal temperature in the control pack to increase above normal limits Open skirt and wait until error clears The system does not detect any water flow while the primary pump is running Check and open water valv...

Страница 10: ...g order Alkalinity pH Chlorine 4 1 ENJOY 7 5 Chlorine Granules Add 15g per 1000L Chlorine level should be 2 3 ppm due to ozone purifier 6 Circulate Cycle water with the cover off for 30 mins 3 WHILE TUB IS FILLING pH Up pH Down Adjust pH level to 7 2 7 6 see bottle for directions Wait 30 mins after adding Alkalinity Booster Adjust alkalinity level to 80 150 ppm use pH Down to reduce see bottle for...

Страница 11: ...g spa water to flush out any buildup in your pipes REPLACE FILTER According to replacement schedule CHANGE WATER Drain and refill your water CHECK UV C BULB purchased separately Ensure LED is on during filter cycle BALANCE Balance you water according to Test Strip readings SPA BALL Replace your Spa Ball once it begins to sink below the surface of your water FILTER FREE Soak filter overnight and ri...

Страница 12: ...pted repairs by anyone other than an authorised Canadian Spa Co service technician Improper installation improper water chemistry improper maintenance acts of god or damage caused beyond the control of Canadian Spa Co is not covered Misuse and abuse shall include any operation of the spa other than as directed in the Canadian Spa Co Manual Examples of misuse and abuse include without limitation Da...

Страница 13: ...z Exigences Électriques 120V 15A Poids 600 lbs Sec 2600 lbs Rempli Capacité d eau 900 L Nombre de jets 14 Nombre de place 5 Taille 74 x 74 x 29 Pompe s 1 x 2 vitesses 1 5 HP Chauffage 1 x 1 kW Filtre s 1 x Filtre Glacier 50 pieds carrés KA 10082 ...

Страница 14: ...s composants audio vidéo supplémentaires etc au système 11 ATTENTION Risque de choc électrique Ne réparez pas ce produit vous même car l ouverture ou le retrait des capots audio peut vous exposer à une tension dangereuse ou à un autre risque de blessure Confiez toutes les réparations à un technicien qualifié 12 ATTENTION Risque de choc électrique Lorsque les connexions d alimentation ou les cordon...

Страница 15: ...male Asseyez vous et détendez vous votre nouveau spa Nous vous proposons d embaucher un électricien agréé à installer votre spa Une fois le spa rempli installez votre nouveau filtre Glacier Retirez les vis et remplissez le spa avec de l eau à travers le boîtier du filtre Visitez notre page de support support canadianspacompany com SPA CHEMICAL S TA R T U P G U I D E canadianspacompany com Guide de d...

Страница 16: ...les Par temps froid assurez vous de placer un chauffant portable à l intérieur de l armoire immédiatement après la livraison pendant 24 à 48 heures avant l installation pour éviter les problèmes de démarrage Un électricien agréé peut installer le câblage en perçant un trou dans n importe quel panneau et en terminant la connexion au pack de contrôle Tous les spas doivent être placés sur une base ap...

Страница 17: ...oir Hot Rouge Hot Blanc Blanc Vue de dessous du GFCI Terminal Neutre Terminal Hot Terminal Hot Terminal de terre 1 2 3 4 Veuillez vous référer au câblage diagramme à l intérieur du spa couvercle du pack pour corriger installation du terminal Pack de contrôle Voltage Correcte Lorsque les sondes sont placées en travers ...

Страница 18: ...NS DES CARACTÉRISTIQUES 1 2 Soupape D aspiration Valve De Contrôle D air Boîtier de filtre 3 4 Centre de contrôle 18 Tem p Do wn JET S 1 Co ntrol Centre Tem p UP JET S 2 ww w c ana dian spa com pan y co m 1 4 2 3 ...

Страница 19: ...cifiques pour un massage précis où le jet de style massage offre un massage circulaire et doux Tous les jets sont interchangeables et réglables Changez les autour et les activer désactiver pour personnaliser à votre satisfaction Directionnel Massage POUR PLUS DE GUIDES D AIDE VISITEZ NOUS À support canadianspacompany com 1 877 909 7727 BOÎTIER DE FILTRE LE CENTRE DE CONTRÔLE C est ici que vous rem...

Страница 20: ...PA Allumer l éclairage Appuyez sur le bouton Light pour activer les lumières Appuyez sue le bouton Light à nouveau pour éteindre Allumer la pompe Appuyez sur le bouton Jets pour allumer la pompe à basse vitesse Appuyez à nouveau sur le bouton pour haute itesse Pour régler l heure maintenez le bouton Light enfoncé jusqu à ce que l heure clignote puis utilisez la flèche pour ajuster le nombre Appuye...

Страница 21: ...érature plus basse Appelez votre marchand ou fournisseur de service si le problème persiste Réglage de l heure de début du cycle de filtrage L écran affichera FSxx xx qui représentant l heure que vous voudriez que le cycle démarre Utilisez le bouton up ou down pour régler Appuyez le bouton lights pour changer la durée Réglage de la durée du cycle de filtrage L écran affichera Fdxx xx représentant ...

Страница 22: ...pa par 1000 L d eau Testez l eau Réglez dans l ordre suivant Alcalinité pH Chlore AMUSEZ VOUS BIEN Granules de Chlore Ajoutez 15 g par 1000 L niveau de chlore devrait être 1 3 ppm à cause du purificateur d ozone Circulation Laissez circuler sans couvercle pour 30 minutes pH Plus pH Moins Réglez le pH à 7 2 7 6 voir les instructions sur la bouteille Booster d Alcalinité Réglez l alcalinité à 80 150...

Страница 23: ...U Videz et remplissez l eau VERIFIER L AMPOULE UV C vendu séparément S assurer que la LED est allumée pendant le cycle de filtration RÉGLEZ Réglez l eau selon les résultats des bandelettes de test BALLE DE SPA Remplacez la balle de spa NETTOYANT DE FILTRE Faites tremper le filtre pendant la nuit et rincez YEARLY POUR PLUS DE GUIDES D AIDE VISITEZ NOUS À support canadianspacompany com 1 877 909 772...

Страница 24: ...couvert par la garantie Cette garantie devient nul si le spa a été soumis à une mauvaise utilisation abus modification ou tentative de modification réparation ou tentative de réparation par toute personne autre qu un technicien de service autorisé par Canadian Spa Mauvaise installation chimie de l eau incorrecte mauvaise entretien actes de force majeure ou dommages causés hors du contrôle de Canad...

Отзывы: