54
ENGLISHENGLISH
GAS HOB UNITS COMBINED WITH RECESSED SINK
▪
FL series
INSTALLATION ON SUPPORT STRUCTURE
The appliance must be mounted on a support structure, made of material fire-retardant and resistant to
heat and with all of the sturdiness requirements indicated by the technical sector standards (for example
EN14749). The work table must be perfectly horizontal and perpendicular to all surrounding vertical panelling.
The area near the appliance could get very hot. Pay the utmost attention and do not place sockets, other
household appliances, power cables, piping and any other heat-sensitive or flammable material in this area.
ATTENTION!
The appliance must be installed in a room without air draughts which can have a negative
effect on combustion. The chosen installation position must also prevent the accumulation of
unburnt gases.
Comply with the sizes indicated in this manual. Any deviation could cause the temperature to rise excessively.
The surrounding surfaces must be able to withstand temperature rises admitted by standard EN30-1-1 and in
compliance with the design of this unit. All combustible material, such as curtains and shelves, must be kept
far away from the appliance. Check the admissible temperature of the materials used for the surrounding
surfaces to guarantee their compliance with the requirements of EN30-1-1.
RECESSED HOLE
The support structure must be provided with a suitable recessed hole. See the following table for the size
of the hole in reference to the purchased model:
sizes
of
recessed
hole
model
a
[mm]
b
[mm]
FL1323
520
320
FL1324
520
320
FL1400
700
320
FL1401
700
320
FL1402
700
320
FL1410
700
320
FL1765
740
325
FL1766
740
325
FL1770
740
325
FL1780
740
325
Details C
85 mm
R10
128 mm
R32
R7
0
FL13XX
85 mm
135 mm
R10
R32
R7
0