ATTENTION - The installation premises must have continuous air
exchange or however such to guarantee normal and correct gas
combustion,
as outlined in the standards in force in the country of
installation (UNI
–
7131)
FUME EXTRACTOR
The appliance is not equipped with a fume and combustion products
exhaust/extractor system Always check the presence in the premises of
appropriate air vents.
If a hood is installed over the hob, consult the assembly instructions of
the hood, which reports the correct distance to maintain.
IGNITION AND ELECTRICAL CONNECTION
The cooker is equipped with an electronic ignition device, composed of a low
voltage generator (12V - DC) which triggers the flame on each of the burners on
the product (hob, gas and grill).
The generator must be correctly connected to the
local electrical distribution mains in DIRECT CURRENT (DC) and VERY LOW VOLTAGE
(12 V).
The generator is located to the rear of the cooker; two connection cables exit the
generator (conductor with positive polarity and conductor with negative polarity).
The free end of the conductor marked with the sign
”+“(positive polarity) should be
connected to the positive pole of the terminal board of the very low voltage
mains or connected to the positive pole of a conductor, while the free end of the
Fig. 8