Can-Fan
|
EC Fan Controller
Can-Fan
|
EC Fan Controller
27
26
LEGEND
1. Speed bar
2. Temperature
3. Temperature hysteresis
4. Humidity
5. Humidity hysteresis
6. Minimum speed
7. Maximum speed
8. Day time
9. Night time
10. Nominal value setting
11. Actual temperature
12. Actual humidity
13. Actual fan speed
14. UP button
15. DOWN button
16. SET/SAVE button
17. Power LED
18. Sensor connection
19. Power supply 12VDC
20. Exhaust air fan (fan1)
21. Intake air fan (fan2)
FOREWORD
Thank you for purchasing a EC fan controller with LCD display. The EC fan
controller is a speed regulator for ventilated rooms to control exhaust or
exhaust and intake air flow. The function of the EC fan controller involves
maintaining a room at constant temperature and humidity different for
day and night time settings keeping a constant negative pressure in the
room to avoid odors escaping.
ma x .
min .
set
save
The power LED blinks and the fan
starts to initialize This takes a few
seconds. As first you will see a
screen with all the LCD segments
and back-light working.
Next it starts initializing the sen
-
sor and in case this screen stays
at this stage, there is a fault with
the sensor or the communication
it self. Check the connection from
the sensor to the device. If it is
still faulty return the device to be
repaired.
Otherwise you will find in a few
seconds the the measured val
-
ue, fan speed bar and day/night
stage.
You find these three buttons on the fan controller UP, DOWN and SAVE/
SET. With the buttons UP and DOWN you can navigate through the single
settings.
If you press DOWN once you will
find the temperature day setting.
This setting you will see for about
10sec. and then it goes automat
-
ically back to the home position
and the back-light stops working.
INSTRUCTIONS
Install the EC fan controller on a wall using the included Velcro fasteners.
Install the light- humidity & temperature sensor which comes with a 4m
long cable at a point where you wish to undertake the measurement. En
-
sure that this is not directly exposed to a heat source or stream of light in
order to obtain the best precise measurement of the ambient air as possi
-
ble. If the measurement cable is too short, it can be extended up to 50m.
Pay attention to the polarity and undertake this when there is no voltage.
An incorrect connection or short circuit will damage sensitive proces
-
sor parts of the appliance! Connect it to the EC fan controller 18. Sensor
connection. Connect the 20 + 21 exhaust and intake air fan with the two
supplied 4m extension cables. Connect the 19. Power supply with a con
-
ventional household outlet.
EN
EN
Содержание BI3168