Control via RS-485 Interface
RS-485 Control Port
485 Control Board Connection Port
485+
(+) CONNECTION TERMINAL (TRX+)
(- ) CONNECTION TERMINAL (TRX-)
485-
Item
Initial value
PROTOCOL
UART MODE
BAUD RATE
Camera ID
STW
RET PKT
ENABLE
8-NONE-1
9600
0
The camera can be controlled by using an external controller equipped with
RS-485 communications.
• To control using a DVR or keyboard controller
Connect the RS-485 cable (TRX+, TRX-) to the connection port of the 485
control board in the DVR or controller.
* RS-485 communication default initial values
• To control the camera, adjust Protocol, Camera ID, Baud rate
in advance.
Note
18
Ultra High Resolution Color Camera
19
Ultra High Resolution Color Camera
Since power specifications differ depending on the model, make sure to check
your model name and specifications before connecting power.
You can connect power as shown in the following figure.
• Check the standard power requirement before connecting to power.
Connecting to Power
For AC / DC power
When the resistance value of copper wire is at [20
˚
C(68
˚
F)]
• As shown in the table above, voltage decreases as the wire gets longer.
Therefore use of an excessively long adaptor output line for connection to
the camera may affect the performance of the camera.
※
Standard voltage for camera operation : DC 12V
±
10%, AC 24V
±
10%
※
There may be some deviation in voltage drop depending on the type of wire
and the manufacturer.
#24(0.22mm
2
)
Copper wire size(AWG)
#22(0.33mm
2
) #20(0.52mm
2
)
#18(0.83mm
2
)
Resistance value( /m)
0.018
0.030
0.050
0.078
Voltage drop(V/m)
0.006
0.011
0.018
0.028
Dual Power Type
(AC 24V/DC 12V, AC 24V Class2)
DC Power Type (DC 12V, 500mA)
AC90~240V-50Hz/60Hz 4.5W
AC90~240V~
50Hz/60Hz 4.5W
■
Installation Procedures