background image

 

 

   

HSEUiREG07201(R2) MANUAL

                 

Camtec Power Supplies GmbH  -  Gewerbestrasse 30  -  DE-76327  Pfinztal / Germany   

P.14/15 (03/2017.02.2) 

Tel. +49 (721) 46596 - 0  Fax +49 (721) 46596 - 77    

www.camtec-gmbh.com

   -   

[email protected]

 

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death) 

 

Connections

 

Clamping Yoke Connector Specifications

 

 

Input / Output connections 

Signal connections plugs 

Tightening torque min. – max. 

1,2 – 2,2Nm (blade 1,0x5,5 DIN5264 ) 

0,2 – 0,25Nm (blade 0,4x2,2 DIN5264) 

Touch-safe protection acc. to DIN VDE 0470 

IP20 plugged/ IP10 unplugged 

Not applicable 

Clamping range, min. – max. 

0,5 – 16mm² / AWG26 – AWG6 

0,2 – 1,5mm² / AWG28 – AWG14 

Solid, H05(07) V-U min. – max. 

0,5 – 16mm² 

0,2 – 1,5mm² 

Stranded, H05(07) V-U min. – max. 

6 – 16mm² 

0,2 – 1,5mm² 

Flexible, H05(07) V-U min. – max. 

0,5 – 16mm² 

0,2 – 1,5mm² 

w. plastic collar ferrule, DIN 46228 pt 4 min. – max. 

2,5 – 10mm² 

0,2 – 1,5mm² 

w. wire end ferrule, DIN 46228 pt 1, min. – max. 

2,5 – 10mm² 

0,2 – 1,5mm² 

Plug gauge in accordance with EN 60999 a x b; ø 

5,4 x 5,1mm; 5,3mm 

2,4 x 1,5mm; 2,3mm 

Pitch (P) 

10,16mm 

3,5mm 

Wire Stripping Length (fine wired)

 

Nominal Cross Section 

Wire End Ferrule 

Stripping Length 

Wire End Ferrule 

Stripping Length 

0,25mm² 

H0,25/5 

5mm 

H0,25/10 HBL 

8mm 

0,5mm² 

H0,5/6 

6mm 

H0,5/12 OR 

8mm 

1,0mm² 

H1,0/6 

6mm 

H1,0/12 GE 

8mm 

2,5mm² 

H2,5/12  

12mm 

H2,5/19D BL  

14mm 

4,0mm² 

H4,0/12 

12mm 

H4,0/20 GDR 

14mm 

6,0mm² 

H6,0/20 

12mm 

H6,0/20 SW 

14mm 

10,0mm² 

H10,0/12 

12mm 

H10,0/22 EB 

15mm 

The length of ferrules is to be chosen depending on the rated voltage. The outside diameter of the plastic collar should not be larger than 
the pitch (P) 

 
 

Ordering Information 

Ordering Codes

 

Product Code 

Information 

Article Number 

HSEUiREG07201.018(R2) 

0-18Vdc 

3041084001CA 

HSEUiREG07201.030(R2) 

0-30Vdc 

3041084002CA

 

HSEUiREG07201.050(R2) 

0-50Vdc 

3041084003CA

 

HSEUiREG07201.060(R2) 

0-60Vdc 

3041084021CA 

HSEUiREG07201.090(R2) 

0-90Vdc 

3041084004CA

 

HSEUiREG07201.130(R2) 

0-130Vdc 

3041084005CA

 

HSEUiREG07201.180(R2)

 

0-180Vdc 

3041084006CA

 

HSEUiREG07201.240(R2)

 

0-240Vdc 

3041084007CA

 

HSEUiREG07201.018PS(R2)  PowerSink / Quick Downward Programming 

3041084011CA 

HSEUiREG07201.030PS(R2)  PowerSink / Quick Downward Programming

 

3041084012CA

 

HSEUiREG07201.050PS(R2)  PowerSink / Quick Downward Programming

 

3041084013CA

 

HSEUiREG07201.060PS(R2)  PowerSink / Quick Downward Programming

 

3041084031CA

 

HSEUiREG07201.090PS(R2)  PowerSink / Quick Downward Programming

 

3041084014CA

 

HSEUiREG07201.130PS(R2)  PowerSink / Quick Downward Programming

 

3041084015CA

 

HSEUiREG07201.180PS(R2)

 

PowerSink / Quick Downward Programming

 

3041084016CA

 

HSEUiREG07201.240PS(R2)

 

PowerSink / Quick Downward Programming

 

3041084017CA

 

Certificate Calibration 

Separate works certificate manufacturer calibration 

Back Plate Kit 

Hart mount plate kit including screws 

2201002001CA 

UI.DRIVE INTERFACE 

USB2.0 Interface & software download 

3041093001CA 

 

 
 
 
 
 
 
 

Содержание HSEUiREG07201 Series

Страница 1: ...oring Reference voltage f autonomous programming Remote Shutdown Sense control 2V per load line Power Good Relay DC ok Quick down programming option PS Precise dynamics on load change Series parallel operation N 1 Natural convection Electronic Inrush Limiter 13 8Arms Up to 90 efficiency EMI EMS EN61000 6 2 3 EN55032 class B EN61010 1 EN61010 2 201 EN62368 1 Model Voltage programmable Current progr...

Страница 2: ...ssembled device pass stress aging to achieve an even level and to prevent from delayed failures Our internal product engineering guidelines provide a clear target Camtec product reputation must say mount and forget Quality is never a mere promise for our team The HSEUiREG laboratory power supplies provide low noise and ripple a very quick programming and a precise setting at high load changes With...

Страница 3: ... It is the exact and real value at the output terminals The latency signal preset to the measured value is negligible since the control circuit is constructed completely analogously Constant Voltage or Constant Current Mode CV CC The device can optionally be operated as a DC voltage source or a constant current source The operating mode is signaled via LED Reference Voltage Uref The devices featur...

Страница 4: ...ted yes Base Load OCP Non required open circuit protected Load Regulation Time 1ms on load switch 10 100 Accuracy Ureg 0 5 Ireg 1 5 Umon 0 5 Imon 1 5 Uref 1 0 Temperature Control yes thermal shutdown autorecovery 60 C outside measuring point distance 50mm Hold Up Time 40ms 230Vac mains buffering at full load Inrush Current 9 8Arms 13 8Apeak 230Vac active electronic inrush protection no simple NTC ...

Страница 5: ...g 2 Ureg Input 3 Ireg Input Current Programming Select 0 5V 0 10V 0 20mA 4 20mA 1 MΩ working resistance with Vprog 500 Ω working resistance with Iprog 4 Ireg Input 5 Umon Output Voltage Monitor Select 0 5Vdc 5mA 0 10Vdc 5mA 6 Umon Output 7 Imon Output Current Monitor Select 0 5Vdc 5mA 0 10Vdc 5mA 8 Imon Output 9 SD Input Control Signal Shutdown Switch Open Collector 10 SD Input 11 Uref Output Refe...

Страница 6: ...mbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death Monitor Outputs Monitor Connections Potentiometer Programming Programming Inputs Shutdown Power OK Relay LED Indication CV GRN Constant voltage CC YEL Constant current SD YEL Shutdown OT RED Over temperature ...

Страница 7: ...e desired set point may be very long The power supply has large built in capacitors and an enormous energy reserve A similar effect occurs by skidding input energy which is not easily removed from the power supply A PowerSink PS modul can be ordered as an option for each HSEUiREG power supply unit The PS option is used for fast down programming and the degradation of skidding energy fed The option...

Страница 8: ...ines can cause damages to the power supply unit External Shutdown SD The power supply is set to the Shutdown mode when the control input is either shorted via a relay contact a switch contact or an NPN transistor with open collector voltage drop 1V current typ 2mA If the shutdown repeals the power supply starts again Using the soft start the current and the voltage rises within continuously to the...

Страница 9: ...0W HSEUiREG07201 240 240Vdc 3 0A 190Vdc 3 8A 720 722W Inrush Current Protection electronic The power supply unit has an electronic current limiter 230Vac 9 8Arms 13 8Apeak It is a precisely working circuit instead of a usual simple NTC solution The accuracy is 10 regardless of the operating temperature and the duty cycles interval 10s We recommend the smallest circuit breaker a characteristic B wi...

Страница 10: ...rors select the line length from the neutral point or from the busbar to the load as short as possible and use the maximum possible conductor cross section Up to 5 pcs HSEUiREG can be paralleled The HSEUiREG models have no internal O ring diode to operate the devices redundant N 1 We recommend using our RED00202 DIN rail redundant device Electrical Safety Factory Test Field Test Owner 60Vdc 2500Vd...

Страница 11: ...increase The following formula shows dv dt i C When an electronic current sink is used the output voltage remains constant at the set value The current sink provides a quick dynamic response Fig 1 Fig 2 Fig 3 A Power Sink see Fig 1 enables fast down programming at low load conditions or without a load For comparison see Figure 2 without and Figure 3 with PS option The PS option must be installed i...

Страница 12: ...in a failure or malfunction could result in injury or death Mechanics ST HD Baseplate Cooling Temperature Management The temperature management of the HSEUiREG series provides a direct dissipation of the main energy losses The internal coolers of the output diodes and the power FETs connect to the back plate cooler It is possible to dissipate about 40 50 of the energy losses out of a system while ...

Страница 13: ...uired and for active devices 15mm space from the sidewalls For proper air convection it is necessary to install the HSEUiREG One can use the DIN Rail installation equiped standard with our patented 35mm DIN Rail bracket according to EN60715 It is easy to mount dismount while snaping it onto the 35mm DIN Rail no tools necessary A wallmount back plate option is availble too It is not allowed to inst...

Страница 14: ... 2 5mm H2 5 12 12mm H2 5 19D BL 14mm 4 0mm H4 0 12 12mm H4 0 20 GDR 14mm 6 0mm H6 0 20 12mm H6 0 20 SW 14mm 10 0mm H10 0 12 12mm H10 0 22 EB 15mm The length of ferrules is to be chosen depending on the rated voltage The outside diameter of the plastic collar should not be larger than the pitch P Ordering Information Ordering Codes Product Code Information Article Number HSEUiREG07201 018 R2 0 18Vd...

Страница 15: ...ation outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for any resulting damage to persons or things 4 Note The device must not be operated without an upstream circuit breaker CB We recommend the use of B Type 16A for 230Vac and 25A for 115Vac It is prohibited to use the unit without PE It may be ...

Отзывы: