That the list of the MAC addresses of the units operated in the Bridge mode is
displayed indicates that the configuration is correct. To be on the safe side, discon
-
nect the transmitter units from the computer and check again if the transmission
proceeds correctly, by clicking the Refresh button. That the devices communicate
with one another indicates that the radio link has been configured and launched
correctly. Type the IP camera address in the address bar of the browser and check
the video streaming quality. Proceed to the installation of the units on the struc-
ture.
The CDS-5IPmini modules allow scanning the ether to detect frequencies used in the
area. This tool comes in very handy while setting the operation channel. Thanks to it,
we know which channels to omit, and which are free and can be used for the wireless
transmission of signals from IP cameras. The selection of a channel which is already
being used by another transmission lines may lead to interferences or even to the loss
of any transmission.
7. Scanning the usage of operation channels.
13
EU
EU
POLISH
MARK
POLISH
MARK
CDS-5IP
MINI
User Guide
In the destination of checking the correctness of the configuration of devices,
parameters of the connection and stabilities of connecting after installing on the
object it is possible to carry out test using the order PING ( the order should be
name down in the command line of the Windows system).
To start the command line in the Windows system click Start button -> start (in
new systems click the text box)
->write down the
CMD
order.
An opened console, in which it is possible to write down model orders.
Testing the correctness of the connection with PING order
Model order 1.
The inspection or the computer can establish contact with the CDS-5IP device
mini, which the assigned address stayed to 192.168.1.1 (IP address 192.168. 1.1
is by default assigned to every new of device of CDS-5IPmini).
In the console table write down the order:
ping 192.168.1.1
and press
“enter"
.
Model announcement which will be shown:
Reply from 192.168.1.1: of bytes = 32 time <1 ms TTL=64
If the response time of the device is shorter than 200-400 ms it means that the
configuration of devices is right.
To make sure that all devices are configured correctly it is possible to carry out an
order PING with the address of every device being found in the installation
(CDS-5IPmini, IP cameras, routers, recorders).
Содержание CDS-5IPmini
Страница 23: ......