background image

 

Set the temperature of the cooling chamber

Press temperature regulation keys 

 (C key) and 

 (D key) to set the temperature inside the 

chamber and the set temperature will shine. The setting range is between 2

 to 8

 (non-

periodic temperature regulation); it will exit from the system in five seconds and the setting 

will take effect. (within five seconds after finishing the setting, press A key or B key to affirm 

the setting state manually and make the setting valid.)

4

2

3

1

5

1. Keys

2. Names of functions of display screen

3. Display control

4. User Mode operation

A. Hi Humidity: High Humidity Mode

B. ON/OFF: start up or shut down the system   

C.

: increase temperature of the cooling chamber

D.

: decrease temperature of the cooling chamber

1

High Humidity figure

2

Temperature region digitron

3

Temperature (

) figure

 Power on for the first time: all shines for three seconds with ringing of start bell.  

Defaulting temperature of the cooling chamber is 5

.

 

Normal operation display:

Temperature display region: when there is a failure, it will show failure codes by turn at a 

priority order; without failure, it will show the set temperature.

High Humidity figure: shine when the system is under High Humidity Mode.

 Display control:

1

Under the normal pattern, it will not shine any more after thirty seconds without opening and 

key operation;

2

When the door is under open state, the display will shine all the time and it will stop shining 

thirty seconds after the door is closed.

3

When a failure happens and it is within "Failure Code", the screen will shine for one time and 

stop to shine after thirty seconds (if the buzzer has been ringing for a long time, press any key 

to cancel the failure bell);

Under start-up mode, press and hold ON/OFF key (B key) for three seconds, the start bell will ring 

and the system will be shut down immediately;

Under shutdown mode, press and hold ON/OFF key (B key) for three seconds, the start bell will 

ring and the system will be started immediately. 

Press ON/OFF key for three seconds to shut down the system and the display screen will not show 

any more. Except ON/OFF key (B key), other keys will stop responding, and compressor, door 

lamp and other loads will be shut down immediately; 

Press ON/OFF key for three seconds to start up the system. Before starting, if the system is at 

High Humidity Mode, the High Humidity figure will shine, otherwise the system will only shine the 

set temperature and all loads will run the mode having been set before shutdown.  

Function introduction

Function introduction

All following functions must be worked under start state. 

 

High Humidity Mode

When the system is not at High Humidity Mode, press and hold Hi Humidity key (A key) for 

three seconds to start the High Humidity Mode and High Humidity figure will be lit up. 

When the system is at High Humidity Mode, press and hold Hi Humidity key (A key) for three 

seconds to exit from the High Humidity Mode and High Humidity figure will not shine any 

more.

When starting High Humidity Mode, cooling chamber will work under High Humidity state to 

improve relative humidity of the air inside the cooling chamber.

5. Illuminating lamp control

6. Door-opening hint and door-opening alarming control  

7. Power-interruption memory and initial power-up state 

When open cooling chamber's door, cooling chamber's illuminating lamp will shine. When 

close cooling chamber's door, cooling chamber's illuminating lamp will not shine any more.

 When meet power interruption, the refrigerator can memory operating mode and state 

before automatically; When power up, it will recover to the state before interruption and run 

the mode having been set before interruption.

 Initial power-up state: the set temperature of cooling chamber is 

5

 and the system is 

not at High Humidity Mode. 

 Memory: include set temperature of cooling chamber, "High Humidity" Mode and 

cumulative working hours of compressor.

For example, if the system has a power failure under High Humidity state, it will continue to 

work at "High Humidity" mode after recovery.

 Start-up and shutdown

A

B

C

D

 I f refrigerator chamber door has been open for 120 seconds, it will ring warning bell

and the bell will ring per 2 seconds till  the door is closed. Press any key to cancel the 
door-opening warning.

,

Содержание FR505NS

Страница 1: ...FR505NS Refrigerator ...

Страница 2: ...nt circuit 4 WARNING Do not use electrical appliances inside the food storage compartments of the appliance unless they are of the type recommended by the manufacturer 5 The appliance has to be unplugged after use and before carrying out user maintenance on the appliance 6 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or l...

Страница 3: ...cal appliances Connect earth wire Earth electrode of the socket must be equipped with a reliable grounding wire Placement Transportation and placement of the refrigerator Transportation Attention Do not invert traverse press and shake the refrigerator When moving the refrigerator angle of inclination shall not be larger than 45 When moving do not make excessive pressure to the door or top cover ot...

Страница 4: ...system and the display screen will not show any more Except ON OFF key B key other keys will stop responding and compressor door lamp and other loads will be shut down immediately Press ON OFF key for three seconds to start up the system Before starting if the system is at High Humidity Mode the High Humidity figure will shine otherwise the system will only shine the set temperature and all loads ...

Страница 5: ...tandards household refrigerator is only applicable to store food and cannot be used for other purpose such as storing blood drugs biological products etc When the refrigerator is not at n o r m a l o p e r a t i o n o r i s destroyed please cut off the power and inform local service center Do not splash the water on the top or back of the refrigerator otherwise it would reduce insulation effect Do...

Страница 6: ...rator door seal must be dismantled off so that the children would not be closed in it by accident Fingerprints are easily left on its exterior Use a dry towel to wipe up Periodically clean the dust both at the back of and under the refrigerator Refrigerator interior should be cleaned frequently so as to avoid foreign odor After the power is cut off use soft towel and neutral detergent to clean and...

Страница 7: ...e upper hinges at last Lower hinge 4 Reassemble the lower hinge axis dismantle the original hinge axis and assemble it at the graphic position 5 Reassemble the upper hinges axis dismantle the hinge axis and assemble by rotating it from the other end of the screw hole 6 Install the upper hinges fixed leg on the left at the right side Door Right Left Change Door Right Left Change 10 11 9 Install top...

Страница 8: ... Fit the lower connecting hinge at the bottom of two cabinets ST 1 Step Put two cabinets together with only 10mm gap Fix the connecting hinge to the place as shown in the picture rd 3 Step Put the bar inside the gap between two cabinets Step finished The connecting 13 ...

Страница 9: ......

Отзывы: