8
Turn on heater settings as desired
(150kW= 60kW & 90kW combined)
CAUTION;
Failure to have proper air flow will cause heater to shut
down, it is imperative to maintain proper air flow.
NOTE:
The red light should come on and air should be pushed through the outlet
port. Check to see that only the red light is on.
Variable Speed Drive is pre-set for optimum air flow/
temperature rise. Based on “Heat Setting” selection, blower
will adjust speed. See Chart below:
TEMPERATURE SETTINGS
HEAT SETTING
BTU/Hr.
CFM
TEMP.RISE
150kW
512,000
14,500
220F+
90kW
307,000
10,000
220F+
60kW
205,000
7,000
180F
FAN ONLY
0
14,500
N/A
SHUTDOWN
1
Move heat ON/OFF control setting to the "OFF" position
2
When cooling fan shuts down you may shut off power source
3
Shut off power source
4
Disconnect all power sources
5
Store heater