Installation Guideline
The installation must be in compliance with the National Electrical Code, your
local electrical and plumbing codes.
1. Make sure the appliance is intact, and the fittings are complete.
2. Please make sure the main power supply, water pressure, grounding conditi-
on, ammeter and wire reach the standard of installation requirement.
3. The appliance must be connected to properly grounded dedicated branch
circuits of proper voltage rating. Ground must be brought to the “ground” at
the circuit breaker panel.
4. This appliance MUST be permanently connected to the fixed circuit breaker. If
you don’t use the heater, please switch off the circuit breaker.
5. DO NOT install this appliance near to tinder or strong magnetic field place.
The appliance can be installed above or under the sink, and unit must only be
mounted in a VERTICAL position near by the water fittings. Please electrify try
the machine after getting through waterway.
Note: For supply connections, use conductors sized on the basis of Ampacity but
rated minimum 167°F(75°C). Suitable recognized strain relief means shall be
provided when the product installed; Connected only to a circuit that is protected
by recognized ground-fault circuit interrupter(GFCI).
Thermal Cut-out
Power Board
Terminal Blocks
Temp. Sensor
Outlet Connection
Bottom Case
Heating Chamber
Triac
Cooling Fin
Coupling Nut
Temp. Sensor
Flowmeter
Inlet Connection
Product Inner Structure