Appendix A.  Configuring the WXT510 

 

Modifying the default configuration of the WXT510 requires the 
purchase of a grey configuration cable; contact Campbell 
Scientific for more information. 

NOTE 

1.

 

Connect one end of the grey Configuration Cable to a COM port on the PC 
and the other end of the cable to the “Service” connector on the WXT510. 

2.

 

Connect a 9 V battery to the Configuration Cable’s battery clip.  The 
female contact of the battery clip is (+). 

3.

 

On your PC, run Vaisala’s WXT Configuration Tool Software and go to 
the Connection Setup Screen. 

4.

 

Enter the settings for each of the Connection Setup Screen’s parameters 
(see Figure A-1).  The default settings are: 

 

Connect using:  enter the COM Port in which the Configuration 
Cable is connected. 

 

Bits per second:  19200 

 

Parity:  8-N-1 

5.

 

Click on the OK button. 

 

FIGURE A-1.  Connection Setup Screen 

A-1 

Содержание WXT510

Страница 1: ...WXT510 Weather Transmitter Revision 4 07 C o p y r i g h t 2 0 0 6 2 0 0 7 C a m p b e l l S c i e n t i f i c I n c ...

Страница 2: ...other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Scientific Inc direct...

Страница 3: ...irection 2 2 3 Precipitation 2 2 4 Barometric Pressure 2 2 5 Air Temperature 2 2 6 Relative Humidity 2 2 7 Assembly 2 3 Installation 2 3 1 Assembling the WXT510 2 3 2 Mounting to a Campbell Scientific Crossarm 4 4 Wiring Table 4 5 Example Programs 4 5 1 CR10X Program 4 5 2 CR1000 Program 5 Appendix A Configuring the WXT510 A 1 Figures 1 Opened WXT510 with the PTU at the right 3 2 A WXT510 with the...

Страница 4: ...WXT510 Table of Contents Table 1 Connections to Campbell Scientific Dataloggers 4 ii ...

Страница 5: ...ure and humidity The WXT510 is preconfigured to provide the minimum average and maximum values for both wind speed and direction Default wind speed units are m s 1 2 Precipitation The WXT510 uses the RAINCAP Sensor to measure accumulated rainfall rain intensity and rain duration Precipitation is measured one raindrop at a time Whenever a raindrop hits the precipitation sensor an electrical signal ...

Страница 6: ...nd steps 2 4 Barometric Pressure Measurement Range 600 to 1100 hPa mbar Accuracy 0 5 hPa 0 to 30 C 1 hPa 52 to 60 C 2 5 Air Temperature Measurement Range 52 to 60 C Accuracy 0 3 C 20 C 2 6 Relative Humidity Measurement Range 0 to 100 RH Accuracy 3 RH 0 to 90 RH 5 RH 90 to 100 RH 2 7 Assembly Input Voltage 5 to 30 Vdc Typical Current Drain 3 mA with default measuring intervals Output SDI 12 Operati...

Страница 7: ...WXT510 Weather Transmitter FIGURE 1 Opened WXT510 with the PTU at the right FIGURE 2 A WXT510 with the PTU inserted inside of it 3 ...

Страница 8: ...onal heater ground see note G G G G Grey Not used Not used Not used Not used Unless special ordered the heater will not be operational for WXT510s purchased from Campbell Scientific Although the heater is not operational the WXT510 will have a pink and yellow wire Do not connect the pink and yellow wire unless the heater is operational NOTE 5 Example Programs 5 1 CR10X Program The following exampl...

Страница 9: ...tion rain hail Get WXT510 Values 10 15 Rc amount Rd duration Ri intensity Hc amount Hd duration Hi intensity 26 SDI 12 Recorder P105 1 0 SDI 12 Address 2 3 Start Measurement aM3 corresponds with Precip Message Command R3 3 2 Port 4 24 Loc Value10 5 1 0 Multiplier 6 0 0 Offset 5 2 CR1000 Program The following example is the portion of a CR1000 program that measures the WXT510 CR1000 Read WXT510 eve...

Страница 10: ...able1 True 1 DataInterval 0 60 Min 10 final data format goes here Minimum 1 Batt_Volt FP2 False False EndTable Main Program BeginProg Scan 15 Sec 1 0 Default Datalogger Battery Voltage measurement Batt_Volt Battery Batt_Volt WXT510 SDI 12 Sensor measurements 1 6 SDI12Recorder WXT510 1 7 0 M1 1 0 WXT510 SDI 12 Sensor measurements 7 9 SDI12Recorder WXT510 7 7 0 M2 1 0 WXT510 SDI 12 Sensor measuremen...

Страница 11: ...ector on the WXT510 2 Connect a 9 V battery to the Configuration Cable s battery clip The female contact of the battery clip is 3 On your PC run Vaisala s WXT Configuration Tool Software and go to the Connection Setup Screen 4 Enter the settings for each of the Connection Setup Screen s parameters see Figure A 1 The default settings are Connect using enter the COM Port in which the Configuration C...

Страница 12: ...self diagnostic verify Enable Heating is NOT selected Heating and self diagnostics Update Interval 15 s Communication protocol select SDI 12 v1 3 User port settings Port type SDI 12 FIGURE A 2 Device Settings Screen 7 Click on the OK button 8 Go to the Sensor Settings Screen see Figure A 3 The default Wind and PTU Update intervals are set to 5 s FIGURE A 3 Sensor Settings Screen A 2 ...

Страница 13: ... Settings are as desired The default settings are shown in Figure A 4 Note Hail accumulation should be checked FIGURE A 4 Message Settings Screen 11 Click on the OK button 12 Close the WXT Configuration Tool 13 Remove the 9 V battery 14 Disconnect the Configuration Cable 15 Secure protective service port cap on PTU A 3 ...

Страница 14: ...Appendix A Configuring the WXT510 This is a blank page A 4 ...

Страница 15: ...This is a blank page ...

Страница 16: ...w campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 rue de T...

Отзывы: